HomeMy WebLinkAboutRESCHECK - 20-00190 - Shaw - 907 Pine Brook Ln - New SFRREScheck Software Version 4.6.5
Compliance Certificate
Project Alpine heating and Air
Energy Code:2015 IECC
Location:Idaho Falls, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:3,585 ft2
Glazing Area 12%
Climate Zone:6 (7918 HDD)
Permit Date:
Construction Site:Owner/Agent:
Alpine Heating And Air
208-523-5542
derik@alpineheatingair.com
Designer/Contractor:
Mechanical Compliance Solutions
Mechanical Compliance Solutions
4181 Aschli lane
Idaho Falls, ID 83406
208-881-3243
gene.mechcompliancesolutions@g
mail.com
Permit Number:
Compliance: Passes using UA trade-off
0.0% Better Than Code Maximum UA:301 Your UA:301
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.540 21.0 0.0 0.057 25
Door 1: Solid 42 0.140 6
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.320 19
Wall 2: Wood Frame, 16" o.c.25 21.0 0.0 0.057 1
Wall 3: Wood Frame, 16" o.c.342 21.0 0.0 0.057 19
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 10 0.320 3
Wall 4: Wood Frame, 16" o.c.578 21.0 0.0 0.057 27
Door 1: Solid 21 0.140 3
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 80 0.320 26
Wall 5: Wood Frame, 16" o.c.342 21.0 0.0 0.057 19
Wall 6: Wood Frame, 16" o.c.27 21.0 0.0 0.057 1
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.320 3
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
578 19.0 0.0 0.045 26
Project Title: Alpine heating and Air
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Gallatine - Shaw - 907 PINE BROOK
LN.rck
Page 1 of 2
03/27/20Report date:
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Basement Wall 2: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
324 19.0 0.0 0.045 13
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.320 10
Basement Wall 3: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
578 19.0 0.0 0.045 25
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 32 0.320 10
Basement Wall 4: Solid Concrete or Masonry
Wall height: 9.0'
Depth below grade: 7.5'
Insulation depth: 9.0'
324 19.0 0.0 0.045 15
Ceiling 1: Flat Ceiling or Scissor Truss 1,858 50.0 0.0 0.026 48
Floor 1: All-Wood Joist/Truss:Over Outside Air 74 38.0 0.0 0.026 2
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: Alpine heating and Air
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Gallatine - Shaw - 907 PINE BROOK
LN.rck
Page 2 of 2
03/27/20Report date: