HomeMy WebLinkAboutPRODUCT INFORMATION - 20-00173 - 156 N 2nd E - Shelfology Fire Sprinkler InstallES-A-C200_C200N ColtTM Series C200 (Colt 200), C200N (Colt 200N) Double Check Valve Assemblies Sizes: 2½" – 10" (65 – 250mm) Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location –––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––– Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Tri-Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • Available for Horizontal, Vertical or N Pattern Installations • Replaceable Check Disc Rubber The Colt C200, C200N Double Check Valve Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water supply system. The Colt C200, C200N may be installed under continuous pressure service and may be subjected to backpressure. The Colt C200, C200N consists of two independently operating check valves, two shutoff valves, and four test cocks. For use in non-health hazard applications. The Colt C200, C200N features Lead Free* construction to comply with Lead Free* installation requirements. LEAD FREE* C200N BFG C200 OSY NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Specifications The Colt C200, C200N Double Check Valve Assembly shall consist of two independent Tri-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tri-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tri-Link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* Double Check Valve Assembly shall be constructed using Lead Free* materials. It shall comply with state codes and standards, where applicable, requiring reduced lead content. Assembly shall be an Ames Fire & Waterworks Colt C200, C200N. * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. SIZE (DN) DIMENSIONS WEIGHT A C (OSY) C (NRS) D G H I J P C200NRS C200OSY C200N NRS C200N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄2 65 303⁄4 781 163⁄8 416 93⁄8 238 31⁄2 89 291⁄16 738 211⁄2 546 151⁄2 393 813⁄16 223 93⁄16 234 115 52 125 57 123 56 133 60 3 80 313⁄4 806 187⁄8 479 101⁄4 260 311⁄16 94 301⁄4 768 221⁄4 565 171⁄8 435 93⁄16 233 101⁄2 267 131 59 145 66 144 65 158 72 4 100 333⁄4 857 223⁄4 578 123⁄16 310 4 102 33 838 231⁄2 597 181⁄2 470 915⁄16 252 113⁄16 284 161 73 161 73 184 83 184 83 6 150 431⁄2 1105 301⁄8 765 16 406 51⁄2 140 443⁄4 1137 331⁄4 845 233⁄16 589 131⁄16 332 15 381 273 124 295 134 314 142 336 152 8 200 493⁄4 1264 373⁄4 959 1915⁄16 506 611⁄16 170 541⁄8 1375 401⁄8 1019 277⁄16 697 1511⁄16 399 173⁄16 437 438 199 480 218 513 233 555 252 10 250 573⁄4 1467 453⁄4 1162 2313⁄16 605 83⁄16 208 66 1676 491⁄2 1257 321⁄2 826 175⁄16 440 20 508 721 327 781 354 891 404 951 431 Dimensions – Weights Configurations • Horizontal • Vertical up • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel • Elastomers: EPDM, Silicone and Buna ‘N’ • Tri-Link Checks: Noryl®, Stainless Steel • Check Discs: Reversible Silicone or EPDM • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel SIZE (DN) DIMENSIONS WEIGHT A C D G H I J P C200BFG C200NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 21⁄2 65 273⁄4 705 8 203 31⁄2 89 297⁄8 759 211⁄2 546 1415⁄16 379 813⁄16 223 9 229 56 25 64 29 3 80 281⁄4 718 85⁄16 211 311⁄16 94 3011⁄16 779 221⁄4 565 157⁄16 392 93⁄16 233 91⁄2 241 54 24 67 30 4 100 29 737 815⁄16 227 311⁄16 94 3115⁄16 811 231⁄2 597 161⁄4 412 915⁄16 252 10 254 61 28 84 38 6 150 361⁄2 927 10 254 5 127 433⁄16 1097 331⁄4 845 1911⁄16 500 131⁄16 332 101⁄2 267 117 53 157 71 8 200 423⁄4 1086 121⁄4 311 61⁄2 165 511⁄16 1297 401⁄8 1019 235⁄16 592 1511⁄16 399 143⁄16 361 261 118 337 153 Noryl® is a registered trademark of SABIC Innovative Plastics™. HA I J G P D C A D C (open) G H J I PC200, C200N C200BFG, C200NBFG Available Models Suffix: NRS — non-rising stem resilient seated gate valves OSY — UL/FM outside stem and yoke, resilient seated gate valves BFG — UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG — Flanged inlet gate connection and grooved outlet gate connection *OSY GxF — Grooved inlet gate connection and flanged outlet gate connection *OSY GxG — Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available — consult factory* *Consult factory for dimensions Pressure – Temperature Tem per a ture Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pres sure: 175 psi (12.1 bar) Approvals • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC) • AWWA C551-92 For additional approval information please contact the factory or visit our website at www.amesfirewater.com psi 14 12 10 8 6 4 2 0 0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 lpm 7.5 15 fps psi 12 10 8 6 4 2 0 psi 12 10 8 6 4 2 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm 7.5 15 fps 21⁄2" (65mm) 3" (80mm) 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 lpm 7.5 12 fps 6" (150mm) 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 lpm 7.5 13 fps 4" (100mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 lpm 7.5 10 fps 10" (250mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 lpm 7.5 10 fps 8" (200mm) psi 24 20 16 12 8 4 0 N VH H N V N V H N V H N H V N H V (**BFG & OSY Only)B64.51015 **** NOTICE Inquire with governing authorities for local installation requirements Capacity UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. *UL Rated Flow *UL Rated Flow Rated Flow Rated Flow Rated Flow Service Flow Service Flow PS I D R O P (* F R I C T I O N L O S S ) PS I D R O P (* F R I C T I O N L O S S ) *UL Rated FlowRated FlowService Flow PS I D R O P (* F R I C T I O N L O S S ) *UL Rated FlowService Flow PS I D R O P (* F R I C T I O N L O S S ) *UL Rated FlowRated FlowService Flow PS I D R O P (* F R I C T I O N L O S S ) *UL Rated FlowRated FlowService Flow PS I D R O P (* F R I C T I O N L O S S ) Horizontal Vertical N - Pattern ES-A-C200C200N 1806 © 2018 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • AmesFireWater.com Hydraulic Calculations Location: 156 N 2nd E, Rexburg, ID 83440, Project Name: Shelfology Drawing Name: Shelfology FP Prep Calculation Date: 3/25/2020 for Design Remote Area Location: Ordinary Group II Area of Application: 1500ft² (Actual 1535ft²) Coverage per Sprinkler: 108ft² Type of sprinklers calculated: 24 Shelfology 1Remote Area Number: Occupancy Classification: No. of sprinklers calculated: Density:0.20gpm/ft² Upright In-rack Demand: Hose Streams:at Node:Type:Allowance at Source N/Aat Node:N/A gpm 9250.00 (including Hose Streams where applicable):Total Water Required 66.251@826.21From Water Supply at Node 9: Type of System: Wet Volume of Dry or PreAction System:N/A Source: Location: 3/6/2020Date:for Node:9 Name of Contractor:FSI Authority Having Jurisdiction: Address: Phone Number: Name of designer: 610 Mallard, Chubbuck, Idaho 83202 208-232-3640 C H N/A N/A Right:Left:Automatic peaking results Notes: 3/25/2020© M.E.P.CAD, Inc.Page 1AutoSPRINK 2018 v14.2.12.0 10:40:18PM1 Hydraulic Graph Water Supply Node: 9 Job Name: Shelfology Remote Area Number: 1 Date: 3/25/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.3/25/2020 Page 2AutoSPRINK 2018 v14.2.12.0 10:40:20PM Hydraulic Graph BOR Job Name: Shelfology Remote Area Number: 1 Date: 3/25/2020 Summary Sheet N 1.85 © M.E.P.CAD, Inc.3/25/2020 Page 3AutoSPRINK 2018 v14.2.12.0 10:40:20PM Device (gpm) Actual Flow Minimum Flow (gpm)(K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Ordinary Group II (1) Job Number: 3-14-2020 - 1 Sprinkler 101 21.60 21.60 5.6 14.878 Sprinkler 102 21.66 21.60 5.6 14.962 Sprinkler 103 21.74 21.60 5.6 15.076 Sprinkler 104 21.84 21.60 5.6 15.211 Sprinkler 105 21.86 21.60 5.6 15.241 Sprinkler 106 21.92 21.60 5.6 15.326 Sprinkler 107 21.92 21.60 5.6 15.328 Sprinkler 108 22.01 21.60 5.6 15.444 Sprinkler 109 22.20 21.60 5.6 15.720 Sprinkler 110 22.23 21.60 5.6 15.753 Sprinkler 111 22.49 21.60 5.6 16.132 Sprinkler 112 22.83 21.60 5.6 16.624 Sprinkler 113 23.01 21.60 5.6 16.885 Sprinkler 114 23.28 21.60 5.6 17.286 Sprinkler 115 23.62 21.60 5.6 17.798 Sprinkler 116 24.55 21.60 5.6 19.213 Sprinkler 117 24.83 21.60 5.6 19.659 Sprinkler 118 25.18 21.60 5.6 20.219 Sprinkler 119 26.22 21.60 5.6 21.915 Sprinkler 120 26.31 21.60 5.6 22.078 Sprinkler 121 26.58 21.60 5.6 22.522 Sprinkler 122 27.31 21.60 5.6 23.783 Sprinkler 123 30.44 21.60 5.6 29.556 Sprinkler 124 30.56 21.60 5.6 29.771 Most Demanding Sprinkler Data © M.E.P.CAD, Inc.3/25/2020 Page 4AutoSPRINK 2018 v14.2.12.0 10:40:27PM Job Name: Shelfology Remote Area Number: 1 Date: 3/25/2020 Node @ @ Supply Analysis Static (psi) Required Pressure (psi)(gpm) Total DemandAvailable (psi) Flow (gpm) Residual (psi)Name 72.0009 66.251826.211494.00 77.32680.000Water Supply Node Analysis NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 2'-6 576.2166.251Supply9 16'-6 21.6014.878Sprinkler101 13'-6 21.6614.962Sprinkler102 13'-6 21.7415.076Sprinkler103 13'-6 21.8415.211Sprinkler104 15'-6 21.8615.241Sprinkler105 13'-6 21.9215.326Sprinkler106 13'-6 21.9215.328Sprinkler107 13'-6 22.0115.444Sprinkler108 14'-6 22.2015.720Sprinkler109 16'-6 22.2315.753Sprinkler110 15'-6 22.4916.132Sprinkler111 14'-6 22.8316.624Sprinkler112 16'-6 23.0116.885Sprinkler113 15'-6 23.2817.286Sprinkler114 14'-6 23.6217.798Sprinkler115 16'-6 24.5519.213Sprinkler116 15'-6 24.8319.659Sprinkler117 14'-6 25.1820.219Sprinkler118 © M.E.P.CAD, Inc.3/25/2020 Page 5AutoSPRINK 2018 v14.2.12.0 10:40:31PM Job Name: Shelfology Remote Area Number: 1 Date: 3/25/2020 NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 16'-6 26.2221.915Sprinkler119 16'-6 26.3122.078Sprinkler120 16'-6 26.5822.522Sprinkler121 16'-6 27.3123.783Sprinkler122 15'-6 30.4429.556Sprinkler123 15'-6 30.5629.771Sprinkler124 15'-6 16.2111 15'-6 17.1362 15'-6 18.3313 15'-6 20.7874 12'-0 34.9275 12'-0 35.2756 12'-0 35.8087 1'-0 63.166Gauge8 12'-6 16.30010 12'-6 16.42111 12'-6 16.56412 12'-6 16.68713 14'-6 16.59514 14'-6 17.53615 14'-6 18.75316 14'-6 21.25817 12'-0 34.76218 © M.E.P.CAD, Inc.3/25/2020 Page 6AutoSPRINK 2018 v14.2.12.0 10:40:31PM Job Name: Shelfology Remote Area Number: 1 Date: 3/25/2020 NotesDischarge at Node (gpm) Pressure at Node (psi) Node TypeElevation (Foot)Node Number 12'-6 16.68519 12'-6 16.80920 13'-6 17.10021 13'-6 18.05522 13'-6 19.29423 13'-6 21.84824 12'-0 34.71525 15'-6 23.63726 15'-6 23.80927 15'-6 24.27628 15'-6 25.60629 14'-6 31.68830 14'-6 31.91531 © M.E.P.CAD, Inc.3/25/2020 Page 7AutoSPRINK 2018 v14.2.12.0 10:40:31PM Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 5'-0 15'-6 6'-0 0.434 0.900 16'-6 1'-0101 1 1 • • • • • Route 1 • • • • •(See Notes) 1.0490 14.87821.60 0.150043 Sprinkler, 21.60 5.6 PO(5'-0) 120 15'-6 8'-0 0.925 15'-6 8'-01 2 1½ 1.6820 16.21143.40 0.115566 Flow (q) from Route 2 65.00 120 15'-6 6'-0 1.195 15'-6 6'-02 3 1½ 1.6820 17.13622.23 0.199124 Flow (q) from Route 10 87.23 120 15'-6 8'-0 2.456 15'-6 8'-03 4 1½ 1.6820 18.33123.01 0.307062 Flow (q) from Route 13 110.24 120 19'-9½ 12'-0 28'-4 1.517 12.623 15'-6 8'-6½4 5 1½(See Notes) 1.6820 20.78724.55 0.445389 Flow (q) from Route 16 134.79 T(9'-11), PO(9'-11) 120 12'-0 9'-3 0.000 0.347 12'-0 9'-35 6 4 4.2600 34.927274.00 0.037558 Flow (q) from Route 4 408.79 120 12'-0 9'-3 -0.000 0.533 12'-0 9'-36 7 4 4.2600 35.275106.41 0.057623 Flow (q) from Route 19 515.21 120 56'-9½ 1'-0 248'-2 4.769 22.589 12'-0 191'-4½7 8 4 (See Notes) 4.2600 35.80861.00 0.070876 Flow (q) from Route 23 576.21 fT(16'-0), 6fE(6'-9½), BFP(-5.0 00), BOR 120 56'-7 2'-6 370'-4½ -0.652 3.737 1'-0 313'-9½8 9 6 (See Notes) 6.3570 63.166 0.010090576.21 3E(17'-7), GV(3'-9½), S 120 9 250.00 Hose Allowance At Source 826.21 Route 1Total(Pt) 66.251 5'-0 12'-6 6'-0 0.434 0.905 13'-6 1'-0102 10 1 • • • • • Route 2 • • • • •(See Notes) 1.0490 14.96221.66 0.150827 Sprinkler, 21.66 5.6 PO(5'-0) 120 © M.E.P.CAD, Inc.3/25/2020 Page 8AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 12'-6 8'-0 0.121 12'-6 8'-010 11 1½ 1.6820 16.300 0.01513221.66 120 7'-5 15'-6 19'-11 -1.301 1.091 12'-6 12'-611 1 1½(See Notes) 1.6820 16.42121.74 0.054742 Flow (q) from Route 3 43.40 3LtE(2'-5½) 120 16.211 Total(Pt)Route 2 5'-0 12'-6 6'-0 0.434 0.911 13'-6 1'-0103 11 1 • • • • • Route 3 • • • • •(See Notes) 1.0490 15.07621.74 0.151896 Sprinkler, 21.74 5.6 PO(5'-0) 120 16.421 Total(Pt)Route 3 5'-0 12'-6 6'-0 0.434 0.919 13'-6 1'-0104 12 1 • • • • • Route 4 • • • • •(See Notes) 1.0490 15.21121.84 0.153154 Sprinkler, 21.84 5.6 PO(5'-0) 120 12'-6 8'-0 0.123 12'-6 8'-012 13 1½ 1.6820 16.564 0.01536521.84 120 4'-11½ 14'-6 13'-11½ -0.867 0.775 12'-6 9'-013 14 1½(See Notes) 1.6820 16.68721.92 0.055587 Flow (q) from Route 7 43.77 2LtE(2'-5½) 120 14'-6 8'-0 0.941 14'-6 8'-014 15 1½ 1.6820 16.59521.86 0.117622 Flow (q) from Route 5 65.63 120 14'-6 6'-0 1.217 14'-6 6'-015 16 1½ 1.6820 17.53622.49 0.202893 Flow (q) from Route 11 88.12 120 14'-6 8'-0 2.505 14'-6 8'-016 17 1½ 1.6820 18.75323.28 0.313066 Flow (q) from Route 14 111.40 120 19'-9½ 12'-0 27'-4 1.084 12.420 14'-6 7'-6½17 18 1½(See Notes) 1.6820 21.25824.83 0.454254 Flow (q) from Route 17 136.23 T(9'-11), PO(9'-11) 120 © M.E.P.CAD, Inc.3/25/2020 Page 9AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 12'-0 9'-3 0.166 12'-0 9'-318 5 4 4.2600 34.762137.77 0.017917 Flow (q) from Route 6 274.00 120 34.927 Total(Pt)Route 4 5'-0 14'-6 6'-0 0.434 0.921 15'-6 1'-0105 14 1 • • • • • Route 5 • • • • •(See Notes) 1.0490 15.24121.86 0.153430 Sprinkler, 21.86 5.6 PO(5'-0) 120 16.595 Total(Pt)Route 5 5'-0 12'-6 6'-0 0.434 0.925 13'-6 1'-0106 19 1 • • • • • Route 6 • • • • •(See Notes) 1.0490 15.32621.92 0.154225 Sprinkler, 21.92 5.6 PO(5'-0) 120 12'-6 8'-0 0.124 12'-6 8'-019 20 1½ 1.6820 16.685 0.01547221.92 120 4'-11½ 13'-6 12'-11½ -0.434 0.725 12'-6 8'-020 21 1½(See Notes) 1.6820 16.80922.01 0.055975 Flow (q) from Route 8 43.93 2LtE(2'-5½) 120 13'-6 8'-0 0.954 13'-6 8'-021 22 1½ 1.6820 17.10022.20 0.119305 Flow (q) from Route 9 66.13 120 13'-6 6'-0 1.239 13'-6 6'-022 23 1½ 1.6820 18.05522.83 0.206510 Flow (q) from Route 12 88.97 120 13'-6 8'-0 2.554 13'-6 8'-023 24 1½ 1.6820 19.29423.62 0.319271 Flow (q) from Route 15 112.59 120 19'-9½ 12'-0 26'-4 0.650 12.217 13'-6 6'-6½24 25 1½(See Notes) 1.6820 21.84825.18 0.463792 Flow (q) from Route 18 137.77 T(9'-11), PO(9'-11) 120 12'-0 9'-3 0.046 12'-0 9'-325 18 4 4.2600 34.715 0.005022137.77 120 34.762 Total(Pt)Route 6 © M.E.P.CAD, Inc.3/25/2020 Page 10AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 5'-0 12'-6 6'-0 0.434 0.925 13'-6 1'-0107 13 1 • • • • • Route 7 • • • • •(See Notes) 1.0490 15.32821.92 0.154238 Sprinkler, 21.92 5.6 PO(5'-0) 120 16.687 Total(Pt)Route 7 5'-0 12'-6 6'-0 0.434 0.932 13'-6 1'-0108 20 1 • • • • • Route 8 • • • • •(See Notes) 1.0490 15.44422.01 0.155316 Sprinkler, 22.01 5.6 PO(5'-0) 120 16.809 Total(Pt)Route 8 5'-0 13'-6 6'-0 0.434 0.947 14'-6 1'-0109 21 1 • • • • • Route 9 • • • • •(See Notes) 1.0490 15.72022.20 0.157881 Sprinkler, 22.20 5.6 PO(5'-0) 120 17.100 Total(Pt)Route 9 5'-0 15'-6 6'-0 0.434 0.949 16'-6 1'-0110 2 1 • • • • • Route 10 • • • • •(See Notes) 1.0490 15.75322.23 0.158194 Sprinkler, 22.23 5.6 PO(5'-0) 120 17.136 Total(Pt)Route 10 5'-0 14'-6 6'-0 0.434 0.970 15'-6 1'-0111 15 1 • • • • • Route 11 • • • • •(See Notes) 1.0490 16.13222.49 0.161712 Sprinkler, 22.49 5.6 PO(5'-0) 120 17.536 Total(Pt)Route 11 5'-0 13'-6 6'-0 0.434 0.998 14'-6 1'-0112 22 1 • • • • • Route 12 • • • • •(See Notes) 1.0490 16.62422.83 0.166263 Sprinkler, 22.83 5.6 PO(5'-0) 120 18.055 Total(Pt)Route 12 5'-0 15'-6 6'-0 0.434 1.012 16'-6 1'-0113 3 1 • • • • • Route 13 • • • • •(See Notes) 1.0490 16.88523.01 0.168680 Sprinkler, 23.01 5.6 PO(5'-0) 120 18.331 Total(Pt)Route 13 5'-0 14'-6 6'-0 0.434 1.034 15'-6 1'-0114 16 1 • • • • • Route 14 • • • • •(See Notes) 1.0490 17.28623.28 0.172378 Sprinkler, 23.28 5.6 PO(5'-0) 120 18.753 Total(Pt)Route 14 © M.E.P.CAD, Inc.3/25/2020 Page 11AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 5'-0 13'-6 6'-0 0.434 1.063 14'-6 1'-0115 23 1 • • • • • Route 15 • • • • •(See Notes) 1.0490 17.79823.62 0.177097 Sprinkler, 23.62 5.6 PO(5'-0) 120 19.294 Total(Pt)Route 15 5'-0 15'-6 6'-0 0.434 1.141 16'-6 1'-0116 4 1 • • • • • Route 16 • • • • •(See Notes) 1.0490 19.21324.55 0.190086 Sprinkler, 24.55 5.6 PO(5'-0) 120 20.787 Total(Pt)Route 16 5'-0 14'-6 6'-0 0.434 1.165 15'-6 1'-0117 17 1 • • • • • Route 17 • • • • •(See Notes) 1.0490 19.65924.83 0.194168 Sprinkler, 24.83 5.6 PO(5'-0) 120 21.258 Total(Pt)Route 17 5'-0 13'-6 6'-0 0.434 1.196 14'-6 1'-0118 24 1 • • • • • Route 18 • • • • •(See Notes) 1.0490 20.21925.18 0.199273 Sprinkler, 25.18 5.6 PO(5'-0) 120 21.848 Total(Pt)Route 18 5'-0 15'-6 6'-0 0.434 1.288 16'-6 1'-0119 26 1 • • • • • Route 19 • • • • •(See Notes) 1.0490 21.91526.22 0.214688 Sprinkler, 26.22 5.6 PO(5'-0) 120 15'-6 8'-0 0.172 15'-6 8'-026 27 1½ 1.6820 23.637 0.02153826.22 120 15'-6 6'-0 0.467 15'-6 6'-027 28 1½ 1.6820 23.80926.31 0.077913 Flow (q) from Route 20 52.53 120 15'-6 8'-0 1.329 15'-6 8'-028 29 1½ 1.6820 24.27626.58 0.166170 Flow (q) from Route 21 79.10 120 19'-9½ 12'-0 28'-4 1.517 8.152 15'-6 8'-6½29 6 1½(See Notes) 1.6820 25.60627.31 0.287628 Flow (q) from Route 22 106.41 T(9'-11), PO(9'-11) 120 35.275 Total(Pt)Route 19 © M.E.P.CAD, Inc.3/25/2020 Page 12AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Pipe Information Node 1 Node 2 Nominal ID Actual ID Fittings & Devices C Factor Total(Pt) Elev(Pe) Friction(Pf) Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. NotesFlow added this step (q) K-Factor Elev 1 Elev 2 Total Flow (Q) Equiv. Length (Foot) (Foot)(Foot) (Foot) Length (Foot) Fitting (Foot) Total (psi) Pf Friction Loss Per Unit 5'-0 15'-6 6'-0 0.434 1.297 16'-6 1'-0120 27 1 • • • • • Route 20 • • • • •(See Notes) 1.0490 22.07826.31 0.216169 Sprinkler, 26.31 5.6 PO(5'-0) 120 23.809 Total(Pt)Route 20 5'-0 15'-6 6'-0 0.434 1.321 16'-6 1'-0121 28 1 • • • • • Route 21 • • • • •(See Notes) 1.0490 22.52226.58 0.220182 Sprinkler, 26.58 5.6 PO(5'-0) 120 24.276 Total(Pt)Route 21 5'-0 15'-6 6'-0 0.434 1.389 16'-6 1'-0122 29 1 • • • • • Route 22 • • • • •(See Notes) 1.0490 23.78327.31 0.231562 Sprinkler, 27.31 5.6 PO(5'-0) 120 25.606 Total(Pt)Route 22 5'-0 14'-6 6'-0 0.434 1.699 15'-6 1'-0123 30 1 • • • • • Route 23 • • • • •(See Notes) 1.0490 29.55630.44 0.283116 Sprinkler, 30.44 5.6 PO(5'-0) 120 14'-6 8'-0 0.227 14'-6 8'-030 31 1½ 1.6820 31.688 0.02840330.44 120 19'-9½ 12'-0 27'-4 1.084 2.809 14'-6 7'-6½31 7 1½(See Notes) 1.6820 31.91530.56 0.102739 Flow (q) from Route 24 61.00 T(9'-11), PO(9'-11) 120 35.808 Total(Pt)Route 23 5'-0 14'-6 6'-0 0.434 1.710 15'-6 1'-0124 31 1 • • • • • Route 24 • • • • •(See Notes) 1.0490 29.77130.56 0.285028 Sprinkler, 30.56 5.6 PO(5'-0) 120 31.915 Total(Pt)Route 24 © M.E.P.CAD, Inc.3/25/2020 Page 13AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Date: 3/25/2020 Job Name: Shelfology Remote Area Number: 1 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90°cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90°Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 4.87 )(150 1.33 140 1.16 130 0.713 100Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc.3/25/2020 Page 14AutoSPRINK 2018 v14.2.12.0 10:40:34PM1 Seismic Bracing Calculations 156 N 2nd E Rexburg, ID 83440 0'-0 1¼ Pipe, Schedule 40 30 0.54" 0 4266lb Tolco Inc (Fig. 4A) UL Listed Pipe Clamp for Sway Bracing 1600lb 800lb FSI 610 Mallard Chubbuck, Idaho 83202 208-232-3640 Brace Information Fastener Information Seismic Brace Attachments Structure Attachment Fitting or Tension-only Bracing System Sway Brace (pipe attachment) Fitting Seismic Brace Assembly Detail (Provide Detail On Plans) Project: Address:: Contractor: Address:: Phone: FAX: Length of Brace: Diameter of Brace: Type of Brace: Angle of Brace: Least Radius of Gyration:* L/R Value:* Maximum Horizontal Load: Make:Model: Listed Load Rating:Adjusted Load Rating: Make: Listed Load Rating: Model: Adjusted Load Rating: Lateral Brace Orientation of Connecting Surface:NFPA Type "A" Machine (Hex) Bolt ½ x 1½ Fastener Type: Size: Construction Type:Steel 1600lbMaximum Load: Tolco Inc 1007½lb (Fig. 980) Universal Swivel Sway Brace Attachment ("SF3") 2015lb Shelfology 30'-0Maximum Spacing: Sprinkler System Load Calculation (Fpw = CpWp) Cp =0.5 Diameter Description QuantityUnit Quantity Unit Weight Weight (Wp) 1½648¾lbPipe, Schedule 10 213'-5(3)4'-2½+2'-6½+(3)13'-2+1'-1 0+(6)21'-0+(3)7'-8½+2'-0½+2' -10+0'-6½+1'-6½+0'-10 3lb 4 247½lbPipe, Schedule 10 21'-021'-0 11¾lb 1 51¼lbPipe, Schedule 40 25'-0(30)0'-10 2lb 947½lb 1089½lb Subtotal Weight (Wp) Total Load (Fpw)544¾lb Wp x 1.150000 Page 1 9:36:17PM3/25/2020AutoSPRINK 2018 v14.2.12.0© M.E.P.CAD, Inc. Seismic Bracing Calculations 156 N 2nd E Rexburg, ID 83440 13'-1 1¼ Pipe, Schedule 40 30 0.54" 291 558lb Tolco Inc (Fig. 4B) Pipe Clamp for Sway Bracing 800lb 400lb FSI 610 Mallard Chubbuck, Idaho 83202 208-232-3640 Brace Information Fastener Information Seismic Brace Attachments Structure Attachment Fitting or Tension-only Bracing System Sway Brace (pipe attachment) Fitting Seismic Brace Assembly Detail (Provide Detail On Plans) Project: Address:: Contractor: Address:: Phone: FAX: Length of Brace: Diameter of Brace: Type of Brace: Angle of Brace: Least Radius of Gyration:* L/R Value:* Maximum Horizontal Load: Make:Model: Listed Load Rating:Adjusted Load Rating: Make: Listed Load Rating: Model: Adjusted Load Rating: Longitudinal Brace Orientation of Connecting Surface:NFPA Type "A" Machine (Hex) Bolt ¼ x 1½ Fastener Type: Size: Construction Type:Steel 400lbMaximum Load: Tolco Inc 1007½lb (Fig. 980) Universal Swivel Sway Brace Attachment ("SF3") 2015lb Shelfology 30'-0Maximum Spacing: Sprinkler System Load Calculation (Fpw = CpWp) Cp =0.5 Diameter Description QuantityUnit Quantity Unit Weight Weight (Wp) 4 695lbPipe, Schedule 10 59'-017'-0+(2)21'-0 11¾lb 695lb 799¼lb Subtotal Weight (Wp) Total Load (Fpw)399¾lb Wp x 1.150000 Page 1 9:36:39PM3/25/2020AutoSPRINK 2018 v14.2.12.0© M.E.P.CAD, Inc. General Description The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13* •1-1/2 Inch (DN40) Male Thread x Female Thread •1-1/2thru6Inch(DN40thruDN150) Groove x Groove *Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition tocheck valves,control valves, and system piping. The Riser Manifoldsmaybeinstalledineitherthe horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises. WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion.Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end-to-end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve. NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non-hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1.Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable Step 2.Connect the drain line, and then close the drain valve. Step 3.Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code. Step 4.Refer to Figure 4 for optional relief valve. Step 5.Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system.Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. Model 513 (13) Riser Manifold 1-1/2 thru 6 Inch (DN40 thru DN150) For NFPA 13 Sprinkler Systems Page 1 of 6 TFP962APRIL, 2006 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Page2of6 TFP962 FIGURE 1 1-1/2 INCH (DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS to the Waterflow Alarm Switches. 6-1/8" (155,6 mm) 12-5/8" (320,7 mm) (131,8 mm) Male x Male NPT 1. Approximate weight, 11.2 lbs. (5,1 kg). Cover Tamper Switches installed internal ULC Listed Manifolds are equipped with2. NOTES: 3/4" (19,1 mm) 1" 5-3/16" NPT 1 Male x Female NPT, Manifolds Groove x Groove 10" (254,0 mm) Manifolds 14-1/4" 11-1/8" (282,6 mm) (362,0 mm) 2 W a t e r f l o w 3 3. CH: Common Hardware 3-1/2" (88,9 mm) QTY. UL/FM Waterflow Alarm Switch: VSR-SF with Paddle, VSR-SF with Paddle and Cover Tamper Switch, ULC/FM DESCRIPTION 1-1/2" Manifold Body, Groove x Groove Male x Female NPT 2 NO. 1 ............... .............. 1..... ....... 1 1 1 N/A 976-519-02 971-096-00 N/A P/N Water Pressure Gauge 300 psi/2000 kPa3 . . 1 2341 Closed) (Normally Drain Valve Inspector's Test & Drain Valve (Normally set to "Drain") TFP962 Page3of6 FIGURE 2 2 thru 6 INCH (DN50 thru DN150) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 9/16 1 (14,3) C Nominal Installation Dimensions in Inches and (mm) 1 4-5/16 (25,4) 4-5/16 (109,5) (109,5) (25,4) 133 Inch 17-3/16 Cover Tamper Switches installed internal to the Waterflow Alarm Switches. ULC Listed Manifolds are equipped with NOTES: CH: Common Hardware2. 1. H C E D 4 Inch (DN80) 6 Inch (DN150) (DN100) A B Drain Valve (Normally Closed) 20-1/2 (436,6) 20-1/2 (520,7) (520,7) (330,2) (330,2) (330,2) 13 13 QTY. 2 INCH (DN50) MANIFOLD DESCRIPTION ULC/FM UL/FM Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, 2" Manifold Body, Groove x Groove 300 psi/2000 kPa Water Pressure Gauge 3 2 NO. 1 1............... .............. ..1 1 .......1 Manifold 2 Inch 2-1/2 Inch (DN50) (DN65) 976-357-01 976-520-01 2341 Size N/A P/N 16-3/4 17-3/16 (425,5) (436,6) A (330,2) (330,2) 13 13 B 3-1/2 18.77-1/86 14-1/4 1-1/4" NPT to "Drain") (Normally set & Drain Valve F Test (422,3) 16-5/8 (469,9) 18-1/2 (362,0) W a t e r f l o w 1 7-9/16 (152,4) (215,9) (192,1) 8-1/2 3 9-1/16 (181,0) 10 (254,0) (230,2) 2 4-1/2 (88,9) 6-5/8 (168,3) (114,3) 2" NPT 2" NPT G 32.7 (8,5) (18,9) 41.6 (14,8) Drain Size 1-1/4" NPT13-3/4 (331,8) 13-1/16 (349,3) (136,5) (146,1) 5-3/8 5-3/4 D 6-3/8 6-7/8 (161,9) (174,6) E 3-1/2 3-1/2 (88,9) (88,9) FG 1" NPT H Weight (6,1) 13.5 16.8 lbs. (kg) (7,6) 2 Waterflow Alarm Switch: 976-520-05 2341 976-357-05 VSC with Paddle, VSC with Paddle and Cover Tamper Switch, ULC/FM UL/FM Water Pressure Gauge 300 psi/2000 kPa3 1.. .............. ............... 1 1 P/N N/A 2341 976-520-04 976-357-04 N/A P/N 1...............UL/FM 300 psi/2000 kPa Water Pressure Gauge Cover Tamper Switch, VSC with Paddle and ULC/FM Groove x Groove 6" Manifold Body, DESCRIPTIONNO. 1 3 ....... 6 INCH (DN150) MANIFOLD QTY. 1 .............. 1.. 1 Groove x Groove 4" Manifold Body, DESCRIPTION Waterflow Alarm Switch: VSC with Paddle, 2 NO. 1 .......1 QTY. 4 INCH (DN100) MANIFOLD 1..............ULC/FM 976-520-02 2341Water Pressure Gauge 300 psi/2000 kPa3 ..1 976-357-02............... Groove x Groove 2-1/2" Manifold Body, Cover Tamper Switch, VSC with Paddle and VSC with Paddle, Waterflow Alarm Switch: DESCRIPTION 2-1/2 INCH (DN65) MANIFOLD 1 UL/FM 2 NO. ....... 1 N/A1 P/NQTY. 1..............ULC/FM 976-520-03 300 psi/2000 kPa Water Pressure Gauge 3 1. . 2341 ............... 3" Manifold Body, Groove x Groove Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, DESCRIPTION 3 INCH (DN80) MANIFOLD 1 2 UL/FM NO. 1 .......1 976-357-03 N/A QTY. P/N Page4of6 TFP962 FIGURE 3 WIRING GUIDANCE INCOMING OUTGOING SINGLE CONDUCTOR TERMINAL PLATE LOOPED SECTION UNINSULATED CLAMPING CONDUCTORS SEPARATE STRIPPED ENDS SWITCH TERMINAL CONNECTIONS CLAMPING TERMINAL PLATE IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD SEVERED CAUTION: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS COM NCNO NO FLOW CONTACTS SPDT (Form C) 5A @ 125 VACCONTACT RATING 2.5A @ 30 VDC .......... .... COM NO NC POWER SIGNAL LOCAL DEVICE NON-SUPERVISED CIRCUITCONDITION END OF LINE RESISTOR COM SUPERVISED CIRCUIT STYLE B/CLASS B CONTROL NO NC PANEL signaling unit, while the other contact is used to operate a local audible or visual annunciator. Switch has two switches, one can be used to operate a central station, proprietary or remove For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm NOTE: (SEE NOTE) COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS SHOWN WITH COVER IN PLACE COM .......... ....CONTACT RATING NO CONTACTS 3A @ 250 VAC 5A @ 125 VAC NC SPDT (Form C) 1mA @ 5 VDC min. Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stallingcontractor orproductmanufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Noattemptistobemadetorepairany Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The alarm/flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise thoseresponsibleformoni- toring proprietary and/or central sta- tion alarms. Alarm/Flow Test Procedure Step 1.Place the test & drain Valve in the “test” position. Step 2.Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3.Verify operation of associated alarms. Step 4.Close the drain valve. Step 5.Place the test & drain Valve in the “drain” position. Step 6.Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7.Close the drain valve. Step 8.Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. TFP962 Page5of6 FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE 1 system outlet piping, and a connection back 3/8" Copper Tubing, 2" (DN50) Manifolds 6" (DN150) Manifolds 4" (DN100) and 3" (DN80) Manifolds To install optional Pressure Relief Trim on must be provided by the installer on the a 1-1/2" (DN40) Manifold, a 1/2" NPT outlet 2-1/2" (DN65) and 1 1 1 .... ... .... 971-124-02 971-124-01 971-124-03 Pressure Relief Valve, DESCRIPTION 175 psi, Nonadjustable NO. 2 QTY. 1. . 198-066-00 P/N CH: Common Hardware with installer supplied 3/8" copper tubing. to the manifold drain trim must be fabricated 3 2 134 2 3 1-1/2" (DN40) Manifold Discard unused trim components. Fabricated 3/8" Copper Tubing Installer 1/2" NPT Outlet 90° Compression Fitting .............. 1" x 1/2" Reducing Hex4 Bushing 1 CH DESCRIPTIONNO. 3 QTY. P/N CH2................Fitting Manifold Drain Trim 3 Provided System Outlet Installer Piping 1-1/2" (DN40) Manifold Only: 2" (DN50), 2-1/2" (DN65), 6" (DN150) Manifold 3" (DN80), 4" (DN100), or Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which havebeensubjecttomisuse,improper installation,corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume forit, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer’s repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,specialorconsequentialdam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, ex- press or implied, including warranties ofmerchantabilityandfitnessforapar- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow alarm switch, P/N (specify). NOTES Orders for Figure 513 may be filled with a Figure 13. The two assemblies are completely interchangeable in function, application, and end-to-end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UL/ULC/FM Assemblies With Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4086 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4087 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4090 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4091 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4092 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4095 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4096 UL/FM Assemblies Without Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4055 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4056 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4060 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4061 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4062 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4065 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4066 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, P/N (specify). 1-1/2" or 2". . . . . . . . . . . . . . . P/N 4063 2-1/2" or 3". . . . . . . . . . . . . . . P/N 4072 4" or 6" . . . . . . . . . . . . . . . . . . P/N 4073 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold,P/N (Ref. Figure 1 or 2, as applicable). Page6of6 TFP962 TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 4 FEBRUARY 2014 TFP172 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2˝ NPT TY323 ......Pendent 5.6K, 1/2˝ NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw . . . . . . . . Bronze Deflector .................Bronze TFP172 Page 2 of 4 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Components: 1/2" NPT 1 5 2 3 4 2" (50,8 mm) Frame Button Sealing Assembly *6 2 - -3 -1 *-6 Deector Compression Screw -5 4 -Bulb 2-7/8" (73,0 mm) DIA. 1-3/8" (34,9 mm) 2" (50,8 mm) WRENCH FLATS 7/16" (11,1 mm) NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN Pipe thread connections per ISO 7-1 can be provided on special request. **DEFLECTOR * Temperature rating is indicated on Deector. DEFLECTOR * * ESCUTCHEON PLATE SEATING SURFACE ** **1/2" NPT UPRIGHTCROSS SECTION PENDENT RECESSED PENDENT WRENCH RECESS (USE ONLY END "A") WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE FIGURE 2 W-TYPE 6 SPRINKLER WRENCH FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. MOUNTING PLATE MOUNTING SURFACE CLOSURE SERIES TY-FRB 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) 1/8" (3,2 mm) 3/8±5/16" (9,5±7,9 mm) 1-3/8" (34,9 mm) 5/8" (15,9 mm) 3/4" (19,1 mm) FLUSH MOUNTING SURFACE SERIES TY-FRB CLOSURE MOUNTING PLATE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) FACE OF SPRINKLER FITTING 1/8" (3,2 mm) 5/16±1/4" (7,9±6,4 mm)1/2" (12,7 mm) 1-3/8" (34,9 mm) FLUSH 7/8" (22,2 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP172 Page 4 of 4 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 SIN 370 5.6K UPRIGHT (1/2˝ NPT)TY313 371 5.6K PENDENT (1/2˝ NPT)TY323 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)** POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C)** Eastern Hemisphere sales only * Use suffix “I” for ISO 7-1 connection; for example, 77-370-4-175-I TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION P/N* 77 – XXX – X – XXX