PROPOSAL REQUEST
Contractor: Construction
Solutions Co. Project Name & No.: Grand Peaks Rexburg - 1906
Proposal Request No.: 05
Date of Issue: 01.31.2020
This is not a change Order, a construction change directive or a direction to proceed with the work described in the
proposed modifications.
Please submit an itemized proposal for changes in the Contract Sum and Contract Time for proposed modifications to the
Contract Documents described herein. Within Ten (10) days, the Contractor must submit this proposal or notify the
Architect, in writing, of the date on which proposal submission is anticipated.
Description: (Written description of the work)
1.1 Please provide a cost proposal to provide the changes outlined below. This request does not imply acceptance of the
proposal.
Provide all materials and labor to extend Waiting 144 to the North to Grid line B per the attached documents. All finishes
and casework are to match existing and be approved by the Owner prior to ordering.
If this is accepted it will need to be submitted to the City of Rexburg as a change to the Building Permit.
Attachments: (List of attached documents that support the description)
Sheet T1.1 Title Sheet
Sheet CR1.1 Code Review
Sheet AS1.1 Site Plan
Sheet D1.1 Demolition Plan
Sheet A1.1 Floor Plan
Sheet A2.1 Building Details
Sheet A3.1 Exterior Elevations
Sheet A4.1 Roof Plan
Sheet A4.2 Roof Details
Sheet A8.2 Interior Elevations
Sheet A10.1 Door & Window Schedules
Sheet A11.1 Reflected Ceiling Plan & Details
Sheet S2.0 Foundation Plan
Sheet S2.1 Roof Framing Plan
Sheet S3.1 Details
Sheet M1.1 Mechanical Floor Plan
Sheet E0.1 Existing Electrical Plan
Sheet E1.0 Lighting Plan
Sheet E2.0 Power/Data Plan
THE PROJECT CONSISTS OF A PARTIAL RENOVATION OF THE EXISTING MEDICAL AND DENTAL CLINIC AND A COMPLETE INTERIOR
RENOVATION, PARTIAL EXTERIOR RENOVATION AND RE-ROOF OF THE ADJACENT BUILDING. THE EXISTING MEDICAL AND DENTAL CLINIC
RENOVATION WILL INCLUDE, ON THE MEDICAL SIDE, RENOVATING TWO OF THE EXISTING OFFICES INTO EXAM ROOMS THAT WOULD INCLUDE
CASEWORK WITH SINKS, RENOVATE THE LAB STORAGE AREA, PROVIDE STORAGE IN THE OLD BREAKROOM AREA AND A CONNECTING
HALLWAY TO THE ADJACENT BUILDING. THE RENOVATION ON THE DENTAL SIDE WILL INCLUDE CONVERTING THREE OF THE EXISTING OFFICES
INTO OPERATORY ROOMS THAT WILL REQUIRE CABINETS WITH SINKS, RELOCATING THE MECHANICAL ROOM TO THE GARAGE, PROVIDE
STORAGE IN THE OLD BREAKROOM AREA AND A CONNECTING HALLWAY TO THE ADJACENT BUILDING. THE RENOVATION WILL ALSO INCLUDE
EXTERIOR IMPROVEMENTS TO THE SOUTH AND NORTH SIDE OF THE BUILDING TO MATCH THE EXISTING EAST ELEVATION.
THE ADJACENT BUILDING WILL INCLUDE A COMPLETE INTERIOR RENOVATION WITH A NEW MENTAL HEALTH SUITE, RESTROOMS, MEDICAL
PROVIDER OFFICES, DENTAL PROVIDER OFFICES, STAFF BREAKROOM, CONFERENCE/MEETING ROOM. THE RENOVATION WILL ALSO INCLUDE
EXTERIOR IMPROVEMENTS TO MATCH THE EXISTING BUILDING WITH A NEW, INVITING ENTRANCE FACING SOUTH AND A COMPLETE ROOF
REPLACEMENT THAT WILL INCLUDE TUBE SKYLIGHTS.
GROSS AREAS:
EXISTING RENOVATION: 6,926
NEW RENOVATION: 5,145
VESTIBULE ADDITION: 96
TOTAL: 12,167 S.F.
OCCUPANCY: B
NO. OF STORIES:1
TYPE OF CONSTRUCTION: V-B
OWNER: GRAND PEAKS MEDICAL
PROJECT ADDRESS:
72 S. 1ST E
REXBURG, ID 83440
BUILDING CODES APPLICABLE:
2015 INTERNATIONAL BUILDING CODE
2015 ENERGY CONSERVATION CODE
2015 INTERNATIONAL MECHANICAL CODE
2017 NATIONAL ELECTRIC CODE
2015 INTERNATIONAL FIRE CODE
2015 INTERNATIONAL FUEL GAS CODE
2017 IDAHO PLUMBING CODE
OWNER: GRANDS PEAKS MEDICAL
ARCHITECT:
GPC ARCHITECTS
18 N. MAIN ST, SUITE 200
PO BOX 330
DRIGGS, ID 83422
PHONE: 208.354.8036
EMAIL: gchadwick@gpcarch.com
CONTACT: GARETT CHADWICK, AIA, LEED AP BD&C
GENERAL CONTRACTOR:
CONSTRUCTION SOLUTIONS COMPANY
2880 E. 14TH N.
AMMON, ID 83401
PHONE: 208.514.4441
EMAIL: travis@cscid.com
CONTACT: TRAVIS SIMMONS
STRUCTURAL ENGINEER:
FROST STRUCTURAL ENGINEERING
1020 LINCOLN ROAD
IDAHO FALLS, ID 83401
PHONE: 208.227.8405
EMAIL: davidp@froststructural.com
CONTACT: DAVID PORTER
NORTH
PROJECT SITE
NOTE: NOT ALL SYMBOLS ARE USED
ARCHITECTURAL
CR1.1 CODE REVIEW
AS1.1 SITE PLAN
D1.1 DEMOLITION FLOOR PLAN
A1.1 FLOOR PLAN
A2.1 BUILDING DETAILS
A3.1 EXTERIOR ELEVATIONS
A4.1 ROOF PLAN
A4.2 ROOF DETAILS
A5.1 BUILDING SECTIONS
A8.1 INTERIOR ELEVATIONS & ENLARGED PLAN
A8.2 INTERIOR ELEVATIONS
A10.1 DOOR & WINDOW SCHEDULES
A11.1 REFLECTED CEILING PLAN & DETAILS
SHEET NUMBER SHEET NUMBER
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
5
9
P
M
T1.1
TITLE SHEET
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
TITLE
T1.1 TITLE SHEET
MECHANICAL ENGINEER:
ENGINEERED SYSTEMS ASSOCIATES, INC.
1355 EAST CENTER STREET
POCATELLO, ID 83201
PHONE: 208.232.0501
EMAIL: esa@engsystems.com
CONTACT: DWAYNE SUDWEEKS, PE
ELECTRICAL ENGINEER:
PAYNE ENGINEERING INC
1823 EAST CENTER STREET
POCATELLO, ID 83201
PHONE: 208.232.4439
EMAIL: payneengineering@gmail.com
CONTACT: TODD PAYNE, PE
STRUCTURAL
S1.0 GENERAL STRUCTURAL NOTES
S1.1 GENERAL STRUCTURAL NOTES/SPECIAL INSPECTIONS
S1.2 TYPICAL DETAILS
S2.0 FOUNDATION PLAN
S2.3 ROOF FRAMING PLAN
S3.0 DETAILS
MECHANICAL
M0.1 MECHANICAL AND PLUMBING DEMO PLAN
M1.1 MECHANICAL FLOOR PLAN
M3.1 MECHANICAL SCHEDULE AND DETAILS
P1.1 PLUMBING FLOOR PLAN
P3.1 PLUMBING SCHEDULE AND DETAILS
ELECTRICAL
E0.0 ELECTRICAL SYMBOLS & DETAILS
E0.1 EXISTING ELECTRICAL PLAN
E1.0 LIGHTING PLAN
E2.0 POWER/DATA PLAN
E3.0 POWER RISER & SCHEDULES
E3.1 ELECTRICAL DETAILS
XXX
ABV Above
A/C Air Conditioning
ACT Acoustical Ceiling Tile
ADJ Adjustable, Adjacent
A.F.F. Above Finish Floor
A.I.B.Air Infiltration Barrier
ALT Alternate
ALUM Aluminum
APPROX Approximate
ARCH Architectural/Architect
BD Board
BLDG Building
BLK Block
BLKG Blocking
BLW Below
BM Beam
B.M. Bench Mark
BN Bullnose
B.O.F. Bottom of Footing
B.O.M.Bottom of Masonry
BRG Bearing
BTM Bottom
BTWN Between
B.U. Built-up
CAB Cabinet
CEM Cement
C.I. Cast Iron
C.J. Control Joint
CLG Ceiling
CLO Closet
C.M. Construction Manager
C.M.U. Concrete Masonry Unit
C.O. Clean out
COL Column
CONC Concrete
CONST.JT.Construction Joint
CONT Continuous
CONTR Contractor
COORD Coordinate
CORR Corridor
CPT Carpet
C.T. Ceramic Tile
CTR Center
C.W. Cold Water
DBL Double
DET Detail
D.F. Drinking Fountain
DIA Diameter
DIM Dimension
DISP Dispenser/Disposal
DN Down
D.P. Dampproofing
DR Door
DRF Draftstopping
D.S. Downspout
DWG Drawing
EA Each
E.C. Electrical Contractor
E.E. Each End
E.I.F.S.Exterior Insulation and
Finish System
E.J. Expansion Joint
E.J.C. Expansion Joint Cover
EL Elevation
ELEC Electrical/Electric
E/O Equipment by Owner
E.P.D.M.Ethylene Propylene
Diene Monomer
E.P.S. Expanded Polystyrene
EQ Equal
EQUIP Equipment
E.W.C. Electric Water Cooler
E.W.S. Exterior Wall System
EXIST or
(e)Existing
EXP Expansion
EXT Exterior
F.D. Floor Drain
FDN Foundation
F.E. Fire Extinguisher
FIN Finish
FLR/FL Floor
F.N.D. Feminine Napkin Disposal
F.N.V. Feminine Napkin Vendor
F.O.B. Face of Brick
F.O.F. Face of Framing
F.O.S. Face of Stud
FR Frame
FT Feet/Foot
FTG Footing
FURR Furring
GA Gauge
GALV Galvanized
G.B. Grab Bar
GEN General
G.I.Galvanized Iron
GL Glass
G.W.B. Gypsum Wallboard
H.B. Hose Bibb
H/C Handicapped
H.C.Hollow Core
H.D. Heavy Duty
HDNR Hardener
HDW Hardware
H.M. Hollow Metal
HORZ Horizontal
HT Height
H.W. Hot Water
ICF Insulated Concrete Form
I.D. Inside Diameter
IN Inch/Inches
INCL Including
INFO Information
INSUL Insulation
INT Interior
INV Invert
JAN Janitor
JT Joint
LKRS Lockers
LOC Location
MASRY Masonry Block
MAT/MAT'L Material
MAX Maximum
MECH Mechanical
MEMB.W.P.Membrane
Waterproofing
MEZZ. Mezzanine
MFR/MFG Manufacturer/
Manufacturing
M.H.Manhole
Min Minimum
MISC Miscellaneous
M.L.P.Metal Liner Panel
M.O.Masonry Opening
M.T.Metal Threshold
MTL Metal
M.T.P.Metal Toilet Partition
(N)New
NEC'Y Necessary
N.I.C.Not in Contract
NOM Nominal
N.T.S.Not to Scale
O.A.F.Overall Frame
O.C.On Center
O.D.Outside Diameter
O.H.Overhead
OPNG Opening
OPP Opposite
OPP.H.Opposite Hand
ORIG Original
O.F.C.I.Owner Furnished
Contractor Installed
O.F.O.I.Owner Furnished
Owner Installed
PL or Plate
P.Lam Plastic Laminate
PLAS Plastic
PLYWD Plywood
PREFAB Prefabricated
PT Paint
P.T.D.Paper Towel Dispenser
P.T.W.Pressure Treated Wood
PTN Partition
QT Quarry Tile
(R)Remove
RAD Radius
R.D.Roof Drain
RECMND Recommendation
REF Reference/Refrigerator
REINF Reinforce/Reinforcing
REQ'D Required
RET Retain/Retained
REV Revisions
R.F.Resilient Flooring
RM Room
R.O.Rough Opening
RTG Rating
S.C.Solid Core
SCHED Schedule
S.C.W.Solid Core Wood
S.D.Soap Dispenser
SECT Section
S.F.Square Feet
S.F.C.Special Floor Coating
S.G.T.Structural Glazed Tile
SHWR Shower
SHT Sheet
SHTG Sheathing
SIM Similar
SPECS Specifications
SQ Square
S.S.Stainless Steel
STD Standard
STL Steel
STOR Storage
STRUCT Structural
SUSP Suspended
S.W.C.Special Wall Coating
TEL Telephone
TEMP Tempered
T.O.BM.Top of Beam
T.O.C.Top of Concrete
T.O.F.Top of Footing
TOIL Toilet
T.O.J.Top of Joist
T.O.M.Top of Masonry
T.O.S.Top of Steel
T.P.D.Toilet Paper Dispenser
TRANS.
FG. PNL.
Translucent Fiberglass
Panel
TRTD Treated
TYP Typical
U.G.Underground
U.L.Underwriters Laboratory
UNEXC Unexcavated
UNFIN Unfinished
U.N.O.Unless Noted Otherwise
U.S.Underside
(V)Verify
V.C.T.Vinyl Composition TIle
VENT Ventilation/Ventilator
VERT Vertical
V.I.F.Verify in Field
VISQ.V.B.Visqueen Vapor Barrier
V.S.G.Vinyl Sheet Goods
V.T.R.Vent Thru Roof
VWC Vinyl Wallcovering
W/With
W.C.Water Closet
WD Wood
WDO Window
W/O Without
W.P.Waterproof
XX.X
X
X
X
X
X
XX.X
X
XX.X
X
XX.X
XX.X
XXX
X
XXX
XX
X
X'-X"CX
XXX
KEY TO SYMBOLSSTANDARD ABBREVIATIONS
VICINITY MAP
BUILDING DATA
INDICATES CENTER LINE
EXTERIOR ELEVATION NUMBER
DETAIL NUMBER
BUILDING SECTION LETTER
WALL SECTION NUMBER
SHEET DRAWN ON
GROUT IN SECTION
RIGID INSULATION IN
SECTION
ACOUSTICAL TILE IN
SECTION
DRYWALL OR PLASTER
IN SECTION
E.I.F.S. IN SECTION
SOUNDBOARD IN
SECTION
PLYWOOD IN SECTION
FINISHED WOOD IN
SECTION
METAL IN SECTION
BRICK IN SECTION
CONCRETE BLOCK IN
LARGE SCALE SECTION
CONCRETE BLOCK IN
SMALL SCALE SECTION
CONCRETE IN SMALL
SCALE SECTION
CONCRETE IN LARGE
SCALE SECTION
GRAVEL IN SECTION
EARTH IN SECTION
STUD WALL
BATT INSULATION
WALL TYPE
LETTER
TOILET ACCESSORY
DEMOLITION KEYED
NOTE & BORROWED LITE
TAG
CEILING TYPE TAG
EXTERIOR WINDOW LETTER
& BORROWED LITE TAG
ROOM NUMBER
KEYED NOTE
NUMBER
INTERIOR & EXTERIOR
DOOR OR GATE NUMBER
SHEET DRAWN ON
SHEET DRAWN ON
SHEET DRAWN ON
INTERIOR ELEVATION NUMBER
SHEET DRAWN ON
INDEX TO DRAWINGS
RCP Reflected Ceiling Plan
PROJECT TEAM
X
PROJECT SUMMARY
CONSTRUCTION DOCUMENTS
ACCESS. Accessory
1/
2
9
/
2
0
2
0
5
:
0
0
:
5
9
P
M
GRAND PEAKS RENOVATION
REXBURG, IDAHO
CO
L
L
E
G
E
A
V
E
CARLSON AVE
E 1ST S
S
1
S
T
E
CO
L
L
E
G
E
A
V
E
CARLSON AVE
E 1ST S
S
1
S
T
E
ADD. NO.
10/09/2019
1
ADD. NO.
10/11/2019
2
CRC
11/8/2019
1
no. description date
1 ADDENDUM #1 10/09/2019
2 ADDENDUM #2 10/11/2019
3 CITY REVIEW
COMMENTS
11/8/2019
9 PR #5 01/29/2020
PR NO.
01/29/2020
5
2
735 SF GROSS
STORAGE
3 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
141
429 SF GROSS
WAITING
5 OCCUPANT(S)
BUSINESS
AREAS
100 GROSS
102
120 SF GROSS
(E) OPERATORY
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A205
121 SF GROSS
(E) OPERATORY
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A206
121 SF GROSS
(E) OPERATORY
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A207
120 SF GROSS
(E) OPERATORY
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A208
117 SF GROSS
OPERATORY
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
137
121 SF GROSS
OPERATORY
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
136
46 SF GROSS
(E) IT
1 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A212
165 SF GROSS
EXAM
2 OCCUPANT(S)
OTUPATIENT
AREAS
100 GROSS
138
95 SF GROSS
(E) EXAM
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A216
142 SF GROSS
(E) XRAY
2 OCCUPANT(S)
OUTPATIENT
AREA
100 GROSS
A218
77 SF GROSS
ELEC
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
132
174 SF GROSS
(E) PROCEDURE
2 OCCUPANT(S)
INSTITUTIONAL
AREA
100 GROSS
A225
91 SF GROSS
(E) EXAM
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A226
90 SF GROSS
(E) EXAM
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A227
99 SF GROSS
(E) EXAM
1 OCCUPANT(S)
OUTPATIENT
AREA
100 GROSS
A228
97 SF GROSS
(E) EXAM
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
A229
120 SF GROSS
(E) NURSE STATION
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A230
118 SF GROSS
(E) RECEPTION
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A231
124 SF GROSS
(E) PHARMACY
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A232
449 SF GROSS
(E) WAITING/RECEPTION
5 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A233
90 SF GROSS
(E) STORAGE
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
A235
109 SF GROSS
EXAM
2 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
139
90 SF GROSS
OPERATORY
1 OCCUPANT(S)
OUTPATIENT
AREAS
100 GROSS
140
161 SF GROSS
(E) LAB
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A244
81 SF GROSS
(E) KID ROOM
1 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
A249
527 SF GROSS
CONFERENCE
6 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
119
253 SF GROSS
BREAKROOM
3 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
118
136 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
116
138 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
114
138 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
109
138 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
107
132 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
127
330 SF GROSS
PLAY THERAPY
4 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
106
115 SF GROSS
MECH/ELEC
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
124 119 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
110120 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
123
122 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
122
121 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
113
121 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
115
122 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
121
125 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
STORAGE
100 GROSS
126
254 SF GROSS
MEDICAL STORAGE
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
133
76 SF GROSS
DENTAL STORAGE
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
134
98 SF GROSS
LAB STORAGE
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
130
143 SF GROSS
LAB
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
129
138 SF GROSS
OFFICE
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
111
48 SF GROSS
MECH
1 OCCUPANT(S)
ACCESSORY
STORAGE
300 GROSS
142
109 SF GROSS
RECEPTION
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
105
84 SF GROSS
DENTAL RECEPTION
2 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
143
2
2
2
2
2
3
6
4
2 2
2
2
1
2
2
1
2
1
3
2
1 1 1
1
2
211
1
2 2
2
2222222
2
1
2
21
1
4
20
11
11
22
19
440 SF GROSS
DENTAL WAITING
4 OCCUPANT(S)
BUSINESS
AREA
100 GROSS
144
PR NO.
01/29/2020
5
AREA OF OCCUPANCY
(SQUARE FEET)
OCCUPANCY LOAD FACTOR
(IBC TABLE 1004.1.2)
ROOM NAME AND NUMBER
CLASSROOM
C104
CLASSROOM
AREA 20 NET
714 SF NET
35 OCCUPANTS
7
EXIT
NUMBER OF OCCUPANTS
DEPICTION OF AND
MEASUREMENT OF DIAGONAL
DISTANCE OF AREA
107 1/8"
ALTERNATE EXIT ROUTE
FUNCTION OF SPACE
(IBC TABLE 1004.1.2)
NUMBER OF OCCUPANTS
(AREA/OCC. LOAD FACTOR)
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
5
1
P
M
CR1.1
CODE REVIEW
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"CR1.1
1 CODE REVIEW PLAN
NORTH
NO. NAME
GROSS
AREA
FUNCTION OF
SPACE
OCCUPANCY
LOAD FACTOR
NO. OF
OCCUPANTS
101 VESTIBULE 75 SF CIRCULATION 0 0
102 WAITING 429 SF BUSINESS AREA 100 GROSS 5
103 VEST. 27 SF CIRCULATION 0 0
104 TOILET 81 SF CIRCULATION 0 5
105 RECEPTION 109 SF BUSINESS AREA 100 GROSS 1
106 PLAY THERAPY 330 SF BUSINESS AREA 100 GROSS 4
107 OFFICE 138 SF BUSINESS AREA 100 GROSS 2
108 RESTROOM 54 SF CIRCULATION 0 0
109 OFFICE 138 SF BUSINESS AREA 100 GROSS 2
110 OFFICE 119 SF BUSINESS AREA 100 GROSS 2
111 OFFICE 138 SF BUSINESS AREA 100 GROSS 2
112 CORR. 444 SF CIRCULATION 0 0
113 OFFICE 121 SF BUSINESS AREA 100 GROSS 2
114 OFFICE 138 SF BUSINESS AREA 100 GROSS 2
115 OFFICE 121 SF BUSINESS AREA 100 GROSS 2
116 OFFICE 136 SF BUSINESS AREA 100 GROSS 2
117 RESTROOM 73 SF CIRCULATION 0 0
118 BREAKROOM 253 SF BUSINESS AREA 100 GROSS 3
119 CONFERENCE 527 SF BUSINESS AREA 100 GROSS 5
120 CORR. 153 SF BUSINESS AREA 100 GROSS 2
121 OFFICE 122 SF BUSINESS AREA 100 GROSS 2
122 OFFICE 122 SF BUSINESS AREA 100 GROSS 2
123 OFFICE 120 SF BUSINESS AREA 100 GROSS 2
124 MECH/ELEC 115 SF ACCESSORY
STORAGE
300 GROSS 1
125 CORR. 520 SF CIRCULATION 0 0
126 OFFICE 125 SF BUSINESS AREA 100 GROSS 2
127 OFFICE 132 SF BUSINESS AREA 100 GROSS 2
128 RESTROOM 61 SF CIRCULATION 0 0
129 LAB 143 SF BUSINESS AREA 100 GROSS 2
130 LAB STORAGE 98 SF ACCESSORY
STORAGE
300 GROSS 1
131 CORR 76 SF CIRCULATION 0 0
132 ELEC 77 SF ACCESSORY
STORAGE
300 GROSS 1
133 MEDICAL
STORAGE
254 SF ACCESSORY
STORAGE
300 GROSS 1
134 DENTAL
STORAGE
76 SF ACCESSORY
STORAGE
300 GROSS 1
135 CORR 99 SF CIRCULATION 0 0
136 OPERATORY 121 SF OUTPATIENT AREAS 100 GROSS 2
137 OPERATORY 117 SF OUTPATIENT AREAS 100 GROSS 2
138 EXAM 165 SF OUTPATIENT AREAS 100 GROSS 2
139 EXAM 109 SF OUTPATIENT AREAS 100 GROSS 1
140 OPERATORY 90 SF OUTPATIENT AREAS 100 GROSS 1
141 STORAGE 735 SF ACCESSORY
STORAGE
300 GROSS 3
142 MECH 48 SF ACCESSORY
STORAGE
300 GROSS 1
143 DENTAL
RECEPTION
84 SF BUSINESS AREA 100 GROSS 2
144 DENTAL
WAITING
440 SF BUSINESS AREA 100 GROSS 4
A205 (E)
OPERATORY
120 SF OUTPATIENT AREAS 100 GROSS 1
A206 (E)
OPERATORY
121 SF OUTPATIENT AREAS 100 GROSS 1
A207 (E)
OPERATORY
121 SF OUTPATIENT AREAS 100 GROSS 1
A208 (E)
OPERATORY
120 SF OUTPATIENT AREAS 100 GROSS 1
A212 (E) IT 46 SF BUSINESS AREA 100 GROSS 1
A215 (E) HALL 427 SF CIRCULATION 0 0
A216 (E) EXAM 95 SF OUTPATIENT AREAS 100 GROSS 1
A218 (E) XRAY 142 SF OUTPATIENT AREAS 100 GROSS 2
A225 (E)
PROCEDURE
174 SF OUTPATIENT AREAS 100 GROSS 2
A226 (E) EXAM 91 SF OUTPATIENT AREAS 100 GROSS 1
A227 (E) EXAM 90 SF OUTPATIENT AREAS 100 GROSS 1
A228 (E) EXAM 99 SF OUTPATIENT AREAS 100 GROSS 1
A229 (E) EXAM 97 SF OUTPATIENT AREAS 100 GROSS 1
A230 (E) NURSE
STATION
120 SF OUTPATIENT AREAS 100 GROSS 2
A231 (E) RECEPTION 118 SF BUSINESS AREA 100 GROSS 2
A232 (E) PHARMACY 124 SF BUSINESS AREA 100 GROSS 2
A233 (E)
WAITING/RECE
PTION
449 SF BUSINESS AREA 100 GROSS 5
A235 (E) STORAGE 90 SF ACCESSORY
STORAGE
300 GROSS 1
A236 (E) HALL 75 SF CIRCULATION 0 0
A240 (E) CORR. 259 SF CIRCULATION 0 0
A244 (E) LAB 161 SF BUSINESS AREA 100 GROSS 2
A247 (E) RESTROOM 40 SF CIRCULATION 0 0
A248 (E) RESTROOM 37 SF CIRCULATION 0 0
A249 (E) KID ROOM 81 SF BUSINESS AREA 100 GROSS 1
A250 (E) VESTIBULE 361 SF CIRCULATION 0 0
A251 (E) WAITING Not Placed BUSINESS AREA 100 GROSS 3
A253 Room Not Placed
A254 Room Not Placed
OCCUPANCY SCHEDULE
CODE REVIEW PLAN LEGEND
CRC
11/8/2019
1
no. description date
3 CITY REVIEW
COMMENTS
11/8/2019
9 PR #5 01/29/2020
PR NO.
01/29/2020
5
X
X
X
X
X
X XXX X
X
X
X
X
X
XX XXXXX
X
X
X
X XX
EXISTING GRAND PEAKS DENTAL & MEDICAL TO BE RENOVATED
EXISTING BUILDING TO BE RENOVATED
EXISTING BUILDING(S)
EXISTING BUILDING(S)
EXISTING BUILDING
EXISTING BUILDING
EXISTING BUILDING
EXISTING BUILDING
41 EXISTING
SPACES
6 SPACES
NEW VESTIBULE
ADDITION
E 1ST E
S
1
S
T
E
CO
L
L
E
G
E
A
V
E
.
024119.09
024119.09
024119.09
321104
321104
321104
321104
TYP.
321216
321313
329300
321216
321313.10
321105.10
321105.20
2'-6"9'-0"15'-0"20'-6"5'-0"
22
'
-
0
"
22
'
-
0
"
2 0 '-0 "
9'-0"
CRC
11/8/2019
1
015000
015000
19'-10 11/16"
NEW WAITING ROOM ADDITION
PR NO.
01/29/2020
5
RENOVATED BUILDING
NEW CONCRETE
NEW ASPHALT
NEW PAINT STRIPING
PROPERTY LINE
EXSISTING BUILDING
EXSISTING CONCRETE
EXISITING ASPHALT
EXISTING GRASSNEW 3/4" CUT ROCK MULCH
EXISTING PAINT
STRIPING
FENCE LINE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
4
6
P
M
AS1.1
SITE PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1" = 20'-0"AS1.1
1 OVERALL SITE PLAN
1. CONTRACTOR TO VERIFY ALL UNDERGROUND UTILITIES PRIOR TO COMMENCEMENT OF
WORK.
2. ITEMS NOT SPECIFICALLY NOTED OR IDENTIFIED AS EXISTING ARE TO BE CONSIDERED
NEW.
3. ALL CURBS AND WALKS SHALL CONFORM TO LOCAL CODES AND ORDINANCES. WHERE
APPARENT DISCREPANCIES OCCUR, CONTACT ARCHITECT FOR CLARIFICATION.
4. SLOPE ALL WALKS, FILLS AND PAVED AREAS AWAY FROM BUILDING, DO NOT EXCEED
CROSS SLOPE OF 2% ON WALKS.
5. LIMIT CONSTRUCTION ACTIVITIES TO AREA'S WITHIN CONSTRUCTION FENCE.
GENERAL NOTES
KEYED NOTES
SITE LEGEND
NORTH
015000 CONSTRUCTION FENCE
024119.09 SELECTIVE DEMOLITION - REMOVE FENCE
321104 PERMANENT PAVEMENT MARKINGS
321105.10 PERMANENT TRAFFIC SIGNING "ONE WAY DO NOT ENTER" - BUILDING MOUNTED
321105.20 PERMAENT TRAFFIC SIGN "RESERVED PARKING VAN ACCESSIBLE" W/ HANDICAP
SYMBOL - POLE MOUNTED
321216 NEW ASPHALT - SLOPE AWAY FROM BUILDING
321313 NEW CONCRETE PAVEMENT - SLOPE AWAY FROM BUILDING
321313.10 NEW VERICAL CURB - 6" WIDE, 12" BELOW GRADE, 8" ABOVE GRADE
329300 NEW ROCK MULCH & SNOW STORAGE AREA
CRC
11/8/2019
1
no. description date
3 CITY REVIEW
COMMENTS
11/8/2019
9 PR #5 01/29/2020
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) IT
(E)
EXAM
(E)
(E) HALL
(E)
(E) EXAM(E)
(E) XRAY(E)
ELEC
(E)
RESTROOM
(E)
(E) PROCEDURE
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) NURSE STATION
(E)
(E) RECEPTION
(E)
(E) PHARMACY
(E)
(E) WAITING/RECEPTION
(E)
(E) STORAGE
(E)
(E) HALL
(E)
(E) CORR.
(E)
EXAM
(E)
OPERATORY
(E)
(E) LAB
(E)
(E) RESTROOM
(E)
(E) RESTROOM
(E)
(E) KID ROOM
(E)
STORAGE
(E)
CORR
(E)
LAB
(E)
CORR
(E)
OFFICE
(E)
BREAK
(E)
OFFICE (E)
OFFICE
(E)
LAB
STORAGE
(E)
LAB
STORAGE
(E)
RESTROOM
1
1
AA
B
C
2
2 3
3
DD
4
4 5
5
1
A5.1
________
1
A5.1
________
2
A5.1
________
3
A5.1
________
4
A5.1
________
5
A5.1
________
024119.01
024119.03
±
5
'
-
6
"
024119.03024119.03
024119.01
024119.01
024119.03
024119.01
024119.01
024119.03024119.03
024119.03024119.03
024119.01
024119.03
024119.01 024119.03
024119.03
024119.02
024119.03
024119.01
024119.03024119.03
024119.03024119.03
024119.01 024119.03024119.03 024119.03
024119.03024119.03
024119.03024119.03024119.03
024119.01
024119.03
024119.01
024119.03
024119.03024119.03024119.03
024119.01
024119.02
024119.04
024119.08
024119.04
024119.11 024119.12024119.12024119.12
024119.10
024119.10
024119.10
024119.10
024119.10
024119.13
024119.13
024119.01
024119.01
024119.01
024119.01
024119.14
024119.14
024119.14
024119.03
024119.03024119.03024119.03
024119.04
024119.03
024119.03
024119.01
024119.12
CRC
11/8/2019
1
CRC
11/8/2019
1
PR NO.
01/29/2020
5
024119.02024119.02
024119.02024119.02
024119.03
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
5
2
P
M
D1.1
DEMOLITION
FLOOR PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"D1.1
1 DEMOLTION FLOOR PLAN
KEYED NOTES
024119.01 SELECTIVE DEMOLITION - REMOVE DOOR, HARDWARE & FRAME
024119.02 SELECTIVE DEMOLITION - REMOVE CASEWORK
024119.03 SELECTIVE DEMOLITION - REMOVE WALL OR PORTION OF WALL AS DIMENSIONED
024119.04 SELECTIVE DEMOLITION - REMOVE SINK & FAUCET
024119.08 SELECTIVE DEMOLITION - REMOVE TOILET
024119.10 SELECTIVE DEMOLITION - REMOVE FLOORING
024119.11 SELECTIVE DEMOLITION - REMOVE FLOORING & SALVAGE FOR RE-USE
024119.12 SELECTIVE DEMOLITION - REMOVE CEILING
024119.13 SELECTIVE DEMOLITION - REMOVE (E) INFILL
024119.14 SELECTIVE DEMOLITION - REMOVE (E) VINYL SIDING, REPAIR (E) CMU AS REQ'D.
FOR NEW FINISH
1. TAKE PROPER PRECAUTIONS DURING DEMOLITION TO PROTECT EXISTING STRUCTURES
AND FINISHES WHICH ARE TO REMAIN. REPAIR ANY MATERIALS DAMAGED BY
CONSTRUCTION ACTIVITIES.
2. SOME UNKNOWN CONDITIONS MAY EXIST. THE CONTRACTOR SHALL VISIT THE SITE TO
BECOME FAMILIAR WITH EXISTING CONDITIONS AND WITH THE EXTENT OF THE WORK.
3. ITEMS IDENTIFIED FOR OWNER REUSE OR SALVAGE SHALL BE CAREFULLY REMOVED,
CLEANED, AND STORED NEATLY AND SECURELY FOR REUSE OR OWNER'S BENEFIT.
4. OWNER RETAINS FIRST RIGHT OF SALVAGE FOR ALL REMOVED ITEMS.
5. COORDINATE DEMOLITION WORK WITH ALL NEW WORK TO BE DONE. ADDITIONAL
DEMOLITION, OTHER THAN THAT SHOWN ON THESE DRAWINGS, MAY BE REQUIRED FOR
COMPLETION OF NEW WORK.
6. DEMOLISHED MATERIALS AND DEBRIS NOT SALVAGED FOR REUSE OR OWNER BENEFIT
SHALL BE REMOVED FROM THE PROJECT SITE AND DISPOSED OF IN A SAFE AND LAWFUL
MANNER.
7. THE EXTENT AND TYPE OF CONSTRUCTION IN CONCEALED SPACES TO BE DEMOLISHED IS
UNKNOWN. CONTRACTOR TO ASSUME FOR BIDDING THAT THE TYPE OF CONCEALED
CONSTRUCTION IS SIMILAR TO ADJACENT TYPICAL TYPES OF CONSTRUCTION.
8. CONTRACTOR TO PROVIDE PROPER SHORING OF LOAD BEARING ELEMENTS DURING
DEMOLITION. COORDINATE WITH STRUCTURAL ENGINEER.
9. AREA OF DEMOLITION, INDICATED THUS:
DEMOLITION NOTES
NORTH
no. description date
3 CITY REVIEW
COMMENTS
11/8/2019
9 PR #5 01/29/2020
REF.
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) OPERATORY(E)
(E) OPERATORY
(E)
(E) IT
EXAM
138
(E)
(E) HALL
(E)
(E) EXAM
(E)
(E) XRAY
ELEC
132
RESTROOM
128
(E)
(E) PROCEDURE (E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) NURSE STATION
(E)
(E) RECEPTION
(E)
(E) PHARMACY
(E)
(E) WAITING/RECEPTION
(E)
(E) KID ROOM
(E)
(E) HALL
(E)
(E) CORR.
EXAM
139
OPERATORY
140
(E)
(E) LAB
(E)
(E) RESTROOM
(E)
(E) RESTROOM
(E)
(E) STORAGE
6'-9"6'-8"6'-3"8'-11"3'-7"12'-9"6'-5"
CONFERENCE
119
BREAKROOM
118
RESTROOM
117
OFFICE
116
OFFICE
114
OFFICE
107
OFFICE
127
PLAY
THERAPY
106
MECH/ELEC
124RESTROOM
108
OFFICE
110
OFFICE
123
OFFICE
122
OFFICE
113
OFFICE
115
OFFICE
121
OFFICE
126
STORAGE
141
117
116
114
111
109
107
121
122
123
124
118
119
126
127
133
128
MEDICAL
STORAGE
133
DENTAL
STORAGE
134
CORR
131
LAB STORAGE
130 LAB
129
CORR
135
OPERATORY
137
4
A3.1
1
1
AA
B
C
2
2 3
3
DD
4
4 5
53
A3.1
A8.1
2
A8.1
11 A8.1
A8.1 16
A8.1 15
14
A8.1
21
A8.1
18
OFFICE
111
OFFICE
109
8'
-
3
"
±
3
7
'
-
3
"
14
'
-
8
"
4'
-
6
"
5'
-
2
"
11
'
-
6
"
11
'
-
6
"
11
'
-
6
"
11
'
-
6
"
11
'
-
6
"
1'
-
8
"
4'
-
1
0
"
13
'
-
1
0
"
13'-5"6'-3"12'-8"12'-6"6'-6"
± 20'-4"± 32'-4"± 23'-9"± 68'-3"
± 144'-8"
13
'
-
1
0
"
4'
-
1
0
"
6'
-
6
"
10
'
-
8
"
9'
-
9
"
11
"
3'
-
5
"
7'
-
1
"
7'
-
9
"
13
'
-
0
"
2'
-
0
"
2'
-
7
"
8'
-
1
"
11
'
-
8
"
±
6
9
'
-
1
0
"
±
1
3
'
-
7
"
±
1
9
'
-
5
"
±
1
0
2
'
-
1
0
"
±
1
0
2
'
-
1
0
"
E2
W2
W2
W2
W2
W2
W5
W2
W2
W5
W2
W2
W2
W2
W2
W2
W2
E1
W1
W1
W2
W5
W1
E2
W3
W2
W5
W2
W2
W5
W2
1
A3.1
MECH
142
RECEPTION
105
OPERATORY
136
VESTIBULE
101
WAITING
102
VEST.
103
TOILET
104
± 1'-9"6'-0"6'-0"6'-0"7"2'-2"10'-5"3'-0"6'-0"5'-11"3'-4"1'-6"± 16'-9"± 1'-8"± 5'-4"± 9'-2"± 1'-8"± 14'-6"± 1'-8"± 14'-10"± 1'-8"± 16'-2"± 6'-4"2'-3"
± 144'-8"
2
A3.1
CORR.
112
CORR.
120
CORR.
125
1
A5.1
________
1
A5.1
________
2
A5.1
________
3
A5.1
________
4
A5.1
________
5
A5.1
________
E1E1
E1
E1
E3E3E3E3E3E3E3E3E3E3E3E3E3E1E2
E1
E4 E4
E5E5
E3E3E3
E1
E1
W2
W3
W2W2
W5
W5
E1
W5
W5
W5
W2
W2
W2
W2
W6W3W5
W2
W3
W2
W3
W2W2
W5
E6
E6
E6
E6
W1
W1
W1
9'-4"
6'
-
0
"
± 7'-7 1/8"3'-5"3'-1"4'-3"± 3'-5"
W1
W4
W4
W7
W7
W7
W8
W8
W1
W5
123623.13064116
064116.10064116.10064116.10
123640123640
123640
123623.13
123640
123623.13
W1
123623.13
123623.13
123623.13123623.13
123623.13123623.13
087100087100
260000
113100.10
113100.30
113100.20
220000220000
260000
079500
079500
079500079500
079500
011000.20
E1
101
102
104
106
108
110
113
115
E3
E2
131
134
142
220000.10
E4
079500
079500
079500
E5
A
A
13
1917
20
A8.1 5
A8.1
3
4
A8.1
6
________1
A8.1
A8.1
14
15
087100
±
3
7
'
-
3
"
± 52'-8"± 92'-0"
1'-9"
E8
B
W8
SIM.
123623.13123623.13
064116064116
064116.10
064116
064113
W2
064113
________1
A8.1
SIM.
________1
A8.1
A8.116
A8.1
14
DENTAL
RECEPTION
143
(E)
(E) WAITING/RECEPTION
(E)
(E) VESTIBULE
CRC
11/8/2019
1
CRC
11/8/2019
1
PR NO.
12/03/2019
1
A
104413
RFI NO.
12/09/2019
4
104413
104413
RFI NO.
12/09/2019
4
RFI NO.
12/09/2019
4
12
PR NO.
1/06/2020
2
PR NO.
1/06/2020
2
PR NO.
1/06/2020
3
PR NO.
1/06/2020
2
PR NO.
1/06/2020
2
22
A8.1 23
PR NO.
1/06/2020
2
A8.1
24
144
260000
8"
064113.20
PR NO.
01/29/2020
5
A
E9
A8.2 2
1 DENTAL
WAITING
144
± 5'-0"
±1:12
RFI NO.
1/15/2020
9
±1:12
± 5'-0"
RFI NO.
1/15/2020
9
DN
DN
A8.2
3
4
W8
W8
SIM.
E1
W1
5/8" TYPE "X" G.W.B.
EACH SIDE
2X4 WOOD STUD W/
FULL BATT INSULATION
W4
5/8" TYPE "X" G.W.B.
EACH SIDE
2X6 WOOD STUD W/
FULL BATT INSULATION
W2
2 LAYERS 5/8" TYPE
"X" G.W.B. EACH SIDE
2X4 WOOD STUD W/
FULL BATT INSULATION
W3
2 LAYERS 5/8" TYPE
"X" G.W.B.
2X4 WOOD STUD W/
FULL BATT INSULATION
5/8" TYPE "X" G.W.B.
W5
2 LAYERS 5/8" TYPE
"X" G.W.B. EACH SIDE
2X6 WOOD STUD W/
FULL BATT INSULATION
EXTERIOR WALL TILE
W6
2 LAYERS 5/8" TYPE
"X" G.W.B.
2X6 WOOD STUD W/
FULL BATT INSULATION
5/8" TYPE "X" G.W.B.
MORTAR SETTING BED
EXISTING CMU
1 1/2" RIGID INSULATION
2X4 WOOD STUD W/ FULL
BATT INSULATION
VAPOR BARRIER
CEMENTITIOUS BOND COAT
WATERPROOF MEMBRANE
CEMENT BACKER BOARD
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
5/8" TYPE "X" G.W.B.
MANUFACTURED STONE
VENEER
E3
FINISH COAT
MORTAR SETTING BED
EXISTING CMU
1/2" BROWN COAT
1/4" SCRATCH COAT
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
MANUFACTURED STONE
VENEER
E2
EXTERIOR WALL TILE
MORTAR SETTING BED
8" CMU
1 1/2" RIGID INSULATION
2X4 WOOD STUD W/ FULL
BATT INSULATION
VAPOR BARRIER
CEMENTITIOUS BOND COAT
WATERPROOF MEMBRANE
CEMENT BACKER BOARD
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
5/8" TYPE "X" G.W.B.
MANUFACTURED STONE
VENEER
E4
FINISH COAT
MORTAR SETTING BED
8" CMU
1/2" BROWN COAT
1/4" SCRATCH COAT
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
MANUFACTURED STONE
VENEER
MORTAR, BOND COAT
MORTOR, SCRATCH COAT
1 1/2" RIGID INSULATION
SHEATHING
2X6 WOOD STUD W/
FULL BATT INSULATION
VAPOR BARRIER
MANUFACTURED STONE
VENEER
5/8" TYPE "X" G.W.B.
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
E5
1 1/2" RIGID INSULATION
2X4 WOOD STUD W/
FULL BATT INSULATION
VAPOR BARRIER
5/8" TYPE "X" G.W.B.
NOTE: REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
E6
8" CMU
E7 MORTAR SETTING BED
8" CMU
MANUFACTURED STONE
VENEER
W7
2X6 WOOD STUD W/
FULL BATT INSULATION
5/8" TYPE "X" G.W.B.
EXISTING CMU
W8
2X6 WOOD STUD W/
FULL BATT INSULATION
5/8" TYPE "X" G.W.B.
EXISTING CMU
8" CMU
E8
8" CMU
E9
FINISH COAT
MORTAR SETTING BED
2" RIGID INSULATION
1/2" BROWN COAT
1/4" SCRATCH COAT
MANUFACTURED
STONE VENEER
8" CMU
VAPOR BARRIER
GAP AS NEEDED TO
ALIGN W/ ADJ. (E) WALL
METAL STUD WALL
W/ FULL THICKNESS
BATT INSULATION
5/8" TYPE 'X' G.W.B.
PR NO.
01/29/2020
5
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
2
6
P
M
A1.1
FLOOR PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A1.1
1 FLOOR PLAN
NORTH
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL HANDRAILS, GRAB BARS, TOILET
ACCESSORIES, CASEWORK, ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL,
STRUCTURAL, MECHANICAL OR ELECTRICAL DRAWINGS, CONTACT ARCHITECT FOR
CLARIFICATION.
3. SEE PLUMBING PLANS FOR EXACT LOCATION OF FLOOR DRAINS. SLOPE ALL CONCRETE
SLABS TOWARDS DRAINS.
4. ALL G.W.B. TO BE 5/8" TYPE 'X', EXCEPT AS NOTED.
5. USE WATER RESISTANT G.W.B. IN ALL WET AREAS INDICATED TO RECIEVE G.W.B. -
JANITOR AREAS & TOILET ROOMS @ FIXTURE WALLS ONLY.
6. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
7. DIMENSIONS ARE TO FACE OF BLOCK, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
8. LOCATE DOOR R.O. 4 1/2" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
9. SEE A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A7 SERIES FOR ENLARGED PLANS.
11. SEE A8 FOR INTERIOR ELEVATIONS FOR TRIM, CASEWORK, TOILET ACCESSORIES, ETC.
12. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
13. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
14. ALL VAPOR BARRIER IN LOCATIONS NOT COVERED WITH G.W.B. MUST MEET FLAME
SPREAD 25 - SEE SPECS. ALL VAPOR BARRIER MUST BE SEALED OR TAPED AT ALL
PENETRATIONS & OPENINGS.
GENERAL NOTES
KEYED NOTES
011000.20 EXISTING POWER POLE TO REMAIN
064113 WOOD-VENEER-FACED ARCHITECTURAL CABINETS TO MATCH (E)
064113.20 WOOD-VENEER-FACED PANEL - SMART SCREEN BOX CABINET W/ ACCESS PANEL
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS TO MATCH (E)
064116.10 MELAMINE SHELVING - PROVIDE BRACKETS FOR SUPPORT AS REQUIRED
079500 EXPANSION CONTROL
087100 DOOR HARDWARE - ADA HANDICAP ACTUATOR
104413 FIRE PROTECTION CABINET
113100.10 RESIDENTIAL APPLAINCE - REFRIGERATOR 35" X 32" - O.F.O.I.
113100.20 RESIDENTIAL APPLIANCE - DISHWASHER - O.F.O.I.
113100.30 RESIDENTIAL APPLIANCE - MICROWAVE - O.F.O.I.
123623.13 PLASTIC-LAMINATE-CLAD COUNTERTOPS TO MATCH (E)
123640 GRANITE COUNTERTOPS TO MATCH (E)
220000 PLUMBING FIXTURE OR EQUIPMENT - SEE PLUMBING
220000.10 PLUMBING FIXTURE OR EQUIPMENT - RELOCATED SINK & ACCESSORIES
260000 ELECTRICAL EQUIPMENT - TV - O.F.O.I.
WALL TYPES
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1 ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
ADD. NO.
10/09/2019
1
SIM.
no. description date
1 ADDENDUM #1 10/09/2019
3 CITY REVIEW
COMMENTS
11/8/2019
5 PR #1 12/03/2019
6 RFI #4 12/09/2019
7 PR #2 1/06/2020
8 PR #3 1/06/2020
9 PR #5 01/29/2020
12 RFI #9 1/15/2020
DOUBLE 2X WOOD BLOCKING FOR
WALL CABINETS, GRAB BARS AND
LARGER ITEMS
SINGLE 2X6 WOOD BLOCKING FOR
ALL MOUNTED TOILET
ACCESSORIES, LOWER CASEWORK
AND SMALLER ITEMS
CA
B
.
H
T
.
CA
B
.
H
T
.
CA
B
.
H
T
.
1
1
/
2
"
C L
1
1
/
2
"
1
1
/
2
"
C L
C L
1
1
/
2
"
C L
SEE DETAIL 3/A2.1
FOR BACKING PLATES
WITHIN WALL
INSTALL BASE AT
CABINETS -SEE
RM. FINISH SCHED.
WALL CABINET -
SEE INT. ELEV.
SEE DETAIL 3/A2.1
FOR BACKING PLATES
WITHIN WALL
BASE CABINET -
SEE INT. ELEV.
INSTALL BASE AT
CABINETS -SEE
RM. FINISH SCHED.
FIRE EXTINGUISHER CABINET
FULL THICKNESS BATT
INSULATION
5/8" TYPE 'X' G.W.B. EA. SIDE
SEE FLOOR PLAN FOR WALL TYPE
PROVIDE FULL PERIMETER
FRAMING
SEMI RECESSED
NOTE:SIMILAR CONDITION FOR ELECTRICAL
PANELS & VALVE BOXES
4'
-
0
"
A
.
F
.
F
.
T
O
C
E
N
T
E
R
O
F
H
A
N
D
L
E
INTERIOR TRIM PACKAGE - TO MATCH (E)
1X6 1X6
1X4 1X4
1X4
1X4
1X6
MDF TRIM
MDF TRIM
1/2"
1/2"1/2"
5"
3"
1X4
2'
-
9
1
/
4
"
NUMBER NAME FLOOR BASE
WALLS CEILING
REMARKSNORTH EAST SOUTH WEST FINISH HEIGHT (+/-)
101 VESTIBULE F5 B1 W1 W1 W1 W1 C1 10'-0"
102 WAITING F1 B1 W1 W1 W1 W1 C1 12'-0" 2
103 VEST. F1 B1 W1 W1 W1 W1 C3 8'-0"
104 TOILET F4 B2 W2, W3 W2, W3 W2, W3 W2, W3 C2 8'-0"
105 RECEPTION F1 B1 W1 W1 W1 W1 C1 9'-0"
106 PLAY THERAPY F1 B1 W1 W1 W1 W1 C1 9'-0" 2
107 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
108 RESTROOM F4 B2 W2, W3 W2, W3 W2, W3 W2, W3 C2 8'-0"
109 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
110 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
111 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
112 CORR. F1 B1 W1 W1 W1 W1 C1 9'-0"
113 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
114 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
115 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
116 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
117 RESTROOM F4 B2 W2, W3 W2, W3 W2, W3 W2, W3 C1 8'-0"
118 BREAKROOM F2 B1 W1 W1 W1 W1 C1 10'-0"
119 CONFERENCE F1 B1 W1 W1 W1 W1 C1 12'-0" 2
120 CORR. F1 B1 W1 W1 W1 W1 C1 9'-0"
121 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
122 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
123 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
124 MECH/ELEC F3 B3 W1 W1 W1, W4 W1, W4 C5 STRUCT.
125 CORR. F1 B1 W1 W1 W1 W1 C1 9'-0"
126 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
127 OFFICE F1 B1 W1 W1 W1 W1 C1 9'-0"
128 RESTROOM - B1 W1 - - W1 C3, C5 EXIST. 1
129 LAB - - - - - W1 C5 EXIST.
130 LAB STORAGE F2 B3 W1 W1 W1 W1 C3 EXIST.
131 CORR F1 B1 W1 W1 W1 W1 C5 EXIST.
132 ELEC - - - - - - - EXIST.
133 MEDICAL STORAGE F2 B3 W1 W1 W1 W1 C5 EXIST.
134 DENTAL STORAGE F2 B3 W1 W1 W1 W1 C5 EXIST.
135 CORR F1 B1 W1 W1 W1 W1 C3 EXIST.
136 OPERATORY F2 B1 W1 W1 W1 W1 C3 EXIST. 2
137 OPERATORY F2 B1 W1 W1 W1 W1 C3 EXIST. 2
138 EXAM F2 B1 W1 W1 W1 W1 C3, C5 EXIST. 2
139 EXAM F2 B1 W1 W1 W1 W1 C3, C5 EXIST. 2
140 OPERATORY F2 B1 W1 W1 W1 W1 C5 EXIST.
141 STORAGE F3 B3 W1 W1 W1 W1 C3, C5 EXIST.
142 MECH F3 B3 W1 W1 W1 W1 C5 EXIST.
143 DENTAL RECEPTION F1 B1 W1 W1 W1 W1 C3 EXIST. 2
144 DENTAL WAITING F1 B1 W1 W1 W1 W1 C3 EXIST., 9'-0" 2
CEILING
C1 24" X 24" ACOUSTIC TILE & GRID SYSTEM
- SEE SPECS
C2 EPOXY PAINTED, TEXTURED, TYPE 'X'
GYPSUM WALL BOARD
C3 PAINTED, TEXTURED, TYPE 'X' GYPSUM
WALL BOARD
C4 OPEN TO ABOVE
C5 (E) CEILING TO REMAIN, PAINT
WALL
W1 TEXTURED AND PAINTED TYPE 'X'
GYPSUM BOARD
W2 TEXTURED AND EPOXY PAINTED TYPE 'X'
GYPSUM BOARD
W3 CERAMIC TILING
W4 PLASTIC PANELING
BASE
B1 5" MDF BASE TO MATCH (E)
B2 NO BASE
B3 RUBBER BASE
FLOOR
F1 TILE CARPETING
F2 WOOD PLANK LVT
F3 (E) CONCRETE - SEALED
F4 CERAMIC TILING
F5 TILE CARPETING - WALK-OFF
1. PROVIDE DESIGNATED BASE FROM ROOM FINISH SCHEDULE AROUND BOTTOM OF
CABINETS, UNLESS OTHERWISE NOTED.
2. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
3. SEE A8 FOR INTERIOR ELEVATIONS FOR CASEWORK, TOILET ACCESSORIES, ETC.
4. PROVIDE FLOOR FILLER AS REQUIRED TO PREPARE SLABS FOR FINISH FLOORING.
5. USE WATER RESISTANT G.W.B. IN ALL WET AREAS INDICATED TO RECIEVE G.W.B. -
JANITOR AREAS & TOILET ROOMS @ FIXTURE WALLS ONLY.
6. PROVIDE IN-WALL BLOCKING/BACKING FOR WALL MOUNTED ITEMS - SEE DETAIL 1/A2.1.
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. BUTTS AGAINST DISSIMILAR MATERIAL
EXCEOT STONE.
8. PROVIDE BACKER BOARD BEHIND ALL TILE WALL FINISHES - DELETE G.W.B.
9. SEE PLUMBING PLANS FOR EXACT LOCATION OF FLOOR DRAINS. SLOPE ALL CONCRETE
SLABS TOWARDS DRAINS.
GENERAL NOTES
ROOM FINISH SCHEDULE LEGEND
ROOM FINISH SCHEDULE
1. RE-USE SALVAGED TILE FOR FLOOR
2. PROVIDE CHAIR RAIL TO MATCH (E)
FINISH SCHEDULE REMARKS
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
2
8
P
M
A2.1
BUILDING
DETAILS
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
NOT TO SCALEA2.1
1 WOOD STUD BACKING DETAIL
NOT TO SCALEA2.1
2 CABINET SECTION @ STUD WALL
1 1/2" = 1'-0"A2.1
3 TYP. FIRE EXTINGUISHER
DOOR NUMBER NAME ROOM NUMBER ACTUAL NAME ON SIGN
NUMBER OF
SIGNS
102 WAITING 102 WAITING ROOM 1
104 TOILET 104 RESTROOM 1
106 PLAY THERAPY 106 PLAY THERAPY 1
107 OFFICE 107 OFFICE 1
108 RESTROOM 108 RESTROOM 1
109 OFFICE 109 OFFICE 1
110 OFFICE 110 OFFICE 1
111 OFFICE 111 OFFICE 1
113 OFFICE 113 OFFICE 1
114 OFFICE 114 OFFICE 1
115 OFFICE 115 OFFICE 1
116 OFFICE 116 OFFICE 1
117 RESTROOM 117 RESTROOM 1
118 BREAKROOM 118 BREAKROOM 1
119 CONFERENCE 119 CONFERENCE ROOM 1
121 OFFICE 121 OFFICE 1
122 OFFICE 122 OFFICE 1
123 OFFICE 123 OFFICE 1
124 MECH/ELEC 124 JANITOR 1
136 OFFICE 126 OFFICE 1
127 OFFICE 127 OFFICE 1
128 RESTROOM 128 RESTROOM 1
133 MEDICAL STORAGE 133 STORAGE 1
134 DENTAL STORAGE 134 STORAGE 1
OPERATORY 136 OPR - VERIFY W/ OWNER 1
OPERATORY 137 OPR - VERIFY W/ OWNER 1
EXAM 138 EXAM 1
EXAM 139 EXAM 1
OPERATORY 140 OPR - VERIFY W/ OWNER 1
DENTAL RECEPTION 143
DENTAL WAITING 144
SIGN SCHEDULE
INFORMATION SHOWN IN THE SIGN SCHEDULE IS FOR REFERENCE ONLY. THE CONTRACTOR SHALL VERIFY THE
INFORMATION TO BE PLACED ON THE SIGNS WITH THE ARCHITECT PRIOR TO ORDERING THE SIGNS. SIGNS TO
MATCH EXISTING.
1/4" = 1'-0"A2.1
4 TRIM PACKAGE
RESTROOM 1
KEEP THIS DOOR CLOSED 1
PR NO.
1/03/2020
4
PR NO.
01/29/2020
5
no. description date
9 PR #5 01/29/2020
10 PR #4 1/03/2020
GROUND FLOOR
ELEV.100' -0"
345
092400
047300
T.O. WALL
±
011000.20
E4 E3
PR NO.
01/29/2020
5
092400
047300
092400.10
076200
GROUND FLOOR
ELEV.100' -0"
ABCD2
A5.1
________3
A5.1
________4
A5.1
________5
A5.1
________
047300
092400
047300
099113099113
011000.20
092400.10
230000
E5 B
2
A4.2
_____
PR NO.
01/29/2020
5
076200
092400
047300
GROUND FLOOR
ELEV.100' -0"
1 2 3 4 5
±
4
'
-
1
0
"
1
A5.1
________
047300
047300
047300
093013093013047300
092400.10
092400.10 092400.10
092400.10092400.10
092400.10
079500 092400
047300
092400.10
011000.20230000TYP.
087100
101419
086223086223
A E1 A
E2
ELEV. 111' - 9"±
T.O. WALL
092400.10
5
A4.2
_____
ADD. NO.
10/11/2019
2
A
092400.10
PR NO.
12/03/2019
1
GROUND FLOOR
ELEV.100' -0"
D2
A5.1
________
092400
047300
047300
092400.10
086223
092400.10
ELEV. 119' - 0"
T.O. WALL
±
T.O. WALL
±
T.O. WALL
±
CRC
11/8/2019
1
CRC
11/8/2019
1
ELEV. 104' - 10"
092400.10
ELEV. 116' - 8"
092400.10
RFI NO.
12/03/2019
2
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
3
2
P
M
A3.1
EXTERIOR
ELEVATIONS
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1. SEE A5 SERIES FOR BUILDING SECTIONS.
2. SEE A8 SERIES FOR INTERIOR ELEVATIONS.
3. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
4. ALL VAPOR BARRIERS MUST BE SEALED OR TAPED AT ALL PENETRATIONS & OPENINGS.
5. COORDINATE THE INSTALLATION OF ALL MATERIALS WITH OTHER TRADES. SEE
STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR
REQUIREMENTS.
GENERAL NOTES
1/8" = 1'-0"A3.1
1 NORTH ELEVATION
1/8" = 1'-0"A3.1
2 EAST ELEVATION
1/8" = 1'-0"A3.1
3 SOUTH ELEVATION
1/8" = 1'-0"A3.1
4 WEST ELEVATION
KEYED NOTES
011000.20 EXISTING POWER POLE TO REMAIN
047300 MANUFACTURED STONE VENEER TO MATCH (E)
076200 GUTTER & DOWNSPOUT
079500 EXPANSION CONTROL
086223 CURB MOUNTED TUBULAR SKYLIGHTS - SEE DETAIL 6/A4.2
087100 DOOR HARDWARE - ADA HANDICAP ACTUATOR
092400 STUCCO TO MATCH (E)
092400.10 STUCCO TRIM TO MATCH (E)
093013 CERAMIC TILING TO MATCH (E)
099113 EXTERIOR PAINTING - PAINT (E) CMU
101419 DIMENSIONAL LETTER SIGNAGE
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
RFI #3:
EXCEPTIONS: A PARAPET NEED NOT BE PROVIDED ON AN EXTERIOR WALL WHERE ANY OF THE
FOLLOWING CONDITIONS EXIST:
3. WALL THAT TERMINATE AT ROOFS OF NOT LESS THAN 2-HOUR FIRE-RESISTANCE-RATED
CONSTRUCTION OR WHERE THE ROOF, INCLUDING THE DECK OR SLAB AND SUPPORTING
CONSTRUCTION, IS CONSTRUCTED ENTIRELY OF NON-COMBUSTIBLE MATERIALS.
no. description date
2 ADDENDUM #2 10/11/2019
3 CITY REVIEW
COMMENTS
11/8/2019
4 RFI #2 12/03/2019
5 PR #1 12/03/2019
9 PR #5 01/29/2020
4
A3.1
1
1
AA
B
C
2
2 3
3
DD
4
4 5
53
A3.1
1
A3.1
2
A3.1
1
A5.1
________
1
A5.1
________
2
A5.1
________
3
A5.1
________
4
A5.1
________
5
A5.1
________
086223086223
086223086223
086223086223
086223
086223
086223
086223
086223
086223
086223086223
086223086223
086223
086223086223
086223
086223086223
1/8" / 12"
1/8" / 12"
1/8" / 12"
1/
8
"
/
1
2
"
±
±
±
011000.30
011000.30
011000.30
011000.30
011000.30
011000.30
011000.30
011000.30
230000
230000
230000
075419
075419
075419
011000.20
230000230000230000
230000230000
230000230000230000
2
A4.2
_____
079500
079500
079500
5
A4.2
_____
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
2
A4.2
_____
ADD. NO.
10/11/2019
2
3
A4.2
_____
4
A4.2
_____
ADD. NO.
10/11/2019
2
1
2
1
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
086223
RFI NO.
1/13/2020
7
RFI NO.
01/29/2020
5 9
A4.2
_____
SIM.
076200
3
A4.2
_____
SIM.
8
A4.2
_____
SIM.
2
10
A4.2
_____
FULLY ADHERED MEMBRANE
OVER 1/2" COVER BOARD
OVER 2 LAYERS BOARD INSULATION
OVER (E) CONCRETE T'S
1 LOW SLOPE MEMBRANE ROOF OVER (E) CONCRETE T'S
VAPOR BARRIER
FULLY ADHERED MEMBRANE
OVER 1/2" COVER BOARD
OVER 2 LAYERS BOARD INSULATION
OVER 2X STRUCTURE -SEE STRUCTURAL
2 LOW SLOPE MEMBRANE ROOF
VAPOR BARRIER
OVER SHEATHING -SEE STRUCTURAL
1/8" = 1'-0"A4.1
1 ROOF PLAN
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
3
4
P
M
A4.1
ROOF PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. LOW SLOPE ROOF: MIN. ROOF SLOPE IS 1/4" PER FOOT. MIN. ROOF CRICKET SLOPE 1/2"
PER FOOT UNLESS NOTED OTHERWISE.
2. REFER TO MECHANICAL DRAWINGS FOR NUMBER AND LOCATION OF V.T.R.'s, EXHAUST
VENTS, ROOF DRAINS, MISC. ROOF PENETRATIONS AND ADDITIONAL INFORMATION.
PROVIDE CRICKETS BEHIND CURBS ON SLOPED ROOFS.
3. VERIFY EXACT NUMBER OF V.T.R.'s AND OTHER ROOF MOUNTED EQUIPMENT WITH
MECHANICAL DRAWINGS. NOT ALL ARE SHOWN.
4. ROOFING CONTRACTOR TO USE APPROPRIATE MANUFACTURER'S DETAILS @ V.T.R.'s,
MECH. CURBS, ETC. TO OBTAIN/MAINTAIN ROOF WARRANTIES. FOLLOW ROOFING MFR.
SYSTEM REQUIREMENTS FOR ALL TERMINATIONS AND SEAMS.
5. WHERE VAPOR BARRIER IS PENETRATED AND AT PERIMETERS OF VAPOR BARRIER,
ENSURE VAPOR BARRIERS ARE SEALED TIGHT.
6. REFER TO ELECTRICAL DRAWINGS FOR ALL CONDUIT PENETRATIONS REQUIRED AT
ROOF.
7. REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING MEMBERS AND DETAILS.
8. PROVIDE MIN. 12" WIDE SPLICE PLATE BENEATH ALL JOINTS IN PARAPET COPING
011000.20 EXISTING POWER POLE TO REMAIN
011000.30 EXISTING WOOD FRAMED OPENINGS
075419 POLYVINYL-CHLORIDE (PVC) ROOFING - REMOVE (E) BALLAST & INSULATION DOWN
TO (E) CONCRETE T'S & REPLACE.
076200 GUTTER & DOWNSPOUT
079500 EXPANSION CONTROL
086223 CURB MOUNTED TUBULAR SKYLIGHTS - SEE DETAIL 6/A4.2
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
KEYED NOTES
ROOF SYSTEMS
NORTH
ADD. NO.
10/11/2019
2
ADD. NO.
10/11/2019
2
no. description date
2 ADDENDUM #2 10/11/2019
9 PR #5 01/29/2020
11 RFI #7 1/13/2020
CUT IN REGLET
ROOF SEALANT
TERMINATION BAR FASTENED 6" O.C.
COUNTER FLASHING
BONDING ADHESIVE
SINGLE PLY MEMBRANE
SPECIFIED SECUREMENT
HOT-AIR WELD
ROOF SYSTEM #1 -SEE ROOF PLAN
SEALANT
18
"
M
I
N
1
2'
-
0
"
M
I
N
.
REGLET - SEE DETAIL 1/A4.2
EXISTING STRUCTURE
EXPANSION CONTROL - SEE SPECS.
WRAP FULLY ADHERE MEMBRANE UP WALL
FULLY ADHERED 2X BUILT-UP CURB
EXISTING STRUCTURE
ROOF SYSTEM #1 - SEE ROOF PLAN
2 1/2" WELDABLE FLASHING W/ DRIP EDGE
PRE-FINISHED METAL FLASHING W/ DRIP
EDGE
FULLY ADHERED BUILT-UP CURB
ROOF SYSTEM #1 - SEE ROOF PLAN
EXISTING STRUCTURE
2X STUD WALL W/ FULL THICKNESS BATT
INSULATION
EXISTING WALL STRUCTURE
REGLET DETAIL - SEE DETAIL 1/A4.2
1'
-
6
"
M
I
N
.
WRAP FULLY ADHERE MEMBRANE UP WALL
EXPANSION CONTROL - SEE SPECS.
BUILT-UP CURB AS REQ'D.
EXISTING MEMBRANE - REPAIR AS REQ'D.
EXISTING STRUCTURE
EXISTING STRUCTURE
1/8" / 12"
1/8" / 12"
2 1/2" WELDABLE FLASHING W/ DRIP EDGE
2X STUD WALL - SEE WALL TYPES
SHEATHING
WRAP FULLY ADHERED MEMBRANE OVER STUCCO TRIM
ROOF SYSTEM #2 - SEE ROOF PLAN
STRUCTURAL FRAMING - SEE STRUCTURAL
STUCCO BUILT-UP CORNICE TO MATCH (E)
(E) STRUCTURE
VAPOR BARRIER, SEE SPECS
SEE SHEET A4.1 FOR ROOF
SYSTEM
INSULATION AS PER
ROOFING SYSTEM
MEMBRANE ROOFING
SEAM SEAL
HOT-AIR WELD
MEMBRANE ROOFING
NOTE:
-SEE SHEET A4.1 FOR SPECIFIC ROOF CONDITIONS AND TYPES.
-ALL ROOF PENETRATIONS TO BE SEALED WITH ICE & WATER SHIELD MATERIAL.
8"
M
I
N
.
COUNTER FLASHING FROM
H.V.A.C. UNIT ( SEE
MECHANICAL DRAWINGS)
OR TUBULAR SKYLIGHT
FASTENED 12" O.C.
BONDING ADHESIVE
INSULATED CURB BY MECH.
ROOF MFR. PLATE FASTENER
INTO & SUPPORT BLOCKING,
INTO DECKING
SINGLE PLY MEMBRANE
ROOFING
ROOF SYSTEM 1 -SEE
PLAN
VARIES
ROOF MANUFACTURER PRE-
MOLDED PIPE SEAL W/
INTEGRAL INTACT RIB
ROOF SEALANT
S.S. DRAW BAND
HOT-AIR WELD
ROOF SEALANT
INSULATION -AS PER
ROOFING SYSTEM
STRUCTURAL FRAMING - SEE STRUCTURAL
ROOF SYSTEM #2 - SEE ROOF PLAN
ROOF SYSTEM #1 - SEE ROOF PLAN
FULLY ADHERE MEMBRANE - SEE SPECS.
EXISTING STRUCTURE
EXISTING STRUCTURE
ROOF SYSTEM #1 - SEE ROOF PLAN
2 1/2" WELDABLE FLASHING W/ DRIP EDGE
EXTEND COVER BOARD & FULLY ADHERED
MEMBRANE OVER STUCCO TRIM
EXTERIOR WALL TILE
CEMENTITIOUS BOND COAT
WATERPROOF MEMBRANE
CEMENT BACKER BOARD
STUCCO BUILT-UP CORNICE TO MATCH (E)
INSULATION AS PER
ROOFING SYSTEM
MEMBRANE ROOFING
SEAM SEAL
HOT-AIR WELD
MEMBRANE ROOFING
ROOF MFR. PLATE FASTENER
INTO & SUPPORT BLOCKING,
INTO DECKING
EXISTING ROOF MEMBRANE &
STRUCTURE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
3
5
P
M
A4.2
ROOF DETAILS
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
3" = 1'-0"A4.2
1 REGLET DETAIL
1" = 1'-0"A4.2
2 ROOF TO (E) WALL
1 1/2" = 1'-0"A4.2
3 (E) WITH NEW ROOF
1 1/2" = 1'-0"A4.2
4 EXPANSION JOINT DETAIL
1" = 1'-0"A4.2
5 NEW ROOF DETAIL
1 1/2" = 1'-0"A4.2
6 MECHANICAL CURB DETAIL
1 1/2" = 1'-0"A4.2
7 VTR DETAIL
1 1/2" = 1'-0"A4.2
8 NEW TO (E) ROOF
1 1/2" = 1'-0"A4.2
9 ROLL OVER W/ TRIM
ADD. NO.
10/11/2019
2
no. description date
2 ADDENDUM #2 10/11/2019
9 PR #5 01/29/2020
1 1/2" = 1'-0"A4.2
10 NEW TO (E) ROOF
PR NO.
01/29/2020
5
9"
6"
2'
-
6
"
123640
092600
064023.20EQ1'-4"1'-4"EQ
2'
-
6
"
6"
9"
123640
064023.20
123640
092600
064113
3'
-
0
"
9"
123640123640
064113.10
EQ EQ EQ EQ EQ
3'
-
0
"
9"
144
064113.10
123640
064023.20
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
3
7
P
M
A8.2
INTERIOR
ELEVATIONS
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
no. description date
9 PR #5 01/29/2020
GENERAL NOTES
1. SEE SHEET A2.1 FOR WALL TYPES & ROOM FINISH SCHEDULE.
2. SEE A10.1 FOR DOOR & WINDOW SCHEDULE.
3. SEE A11.1 FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL,
STRUCT., MECH. OR ELEC. DWGS., CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8" TYPE 'X', EXCEPT AS NOTED.
6. SEE STRUCT. DWGS. FOR CONTROL JOINTS IN FLOOR SLABS.
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MAT'L
8. DIMENSIONS ARE TO FACE OF STUD, FACE OF BLOCK, OR GRID LINE U.N.O.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL HANDRAILS, GRAB BARS, TOILET
ACCESSORIES & OTHER WALL MOUNTED ITEMS.
10. SEE A7.1 FOR TOILET ACCESSORY MOUNTING HEIGHTS.
064023.20 MDF BASE TRIM TO MATCH (E)
064113 WOOD-VENEER-FACED ARCHITECTURAL CABINETS TO MATCH (E)
064113.10 WOOD-VENEER-FACED PANELS FOR CASEWORK TO MATCH (E)
092600 GYPSUM BOARD ASSEMBLIES
123640 GRANITE COUNTERTOPS TO MATCH (E)
KEYED NOTES
1/4" = 1'-0"A8.2
1 DENTAL RECEPTION 143
1/4" = 1'-0"A8.2
2 DENTAL RECEPTION 143
1/4" = 1'-0"A8.2
3 DENTAL WAITING 144
1/4" = 1'-0"A8.2
4 DENTAL WAITING 144
PR NO.
01/29/2020
5
2"
1'
-
8
"
2"
6'
-
4
"
8"
9'
-
0
"
2"1'-4"2"SEE SCH.2"1'-4"2"
9'-4"
A ALUMINUM STOREFRONT
A EXTERIOR ALUMINUM
STOREFRONT
E INTERIOR ALUMINUM
STOREFRONT
2"
SE
E
S
C
H
.
7'
-
2
"
B ALUMINUM CLAD WOOD
B EXTERIOR ALUMINUM CLAD
WOOD
C EXTERIOR ALUMINUM CLAD
WOOD
D EXTERIOR OVERHEAD SECTIONAL DOOR F INTERIOR COMPOSITE DOOR
TO MATCH (E)
C WOOD FRAME TO MATCH (E)
TO
M
A
T
C
H
(
E
)
±
6
'
-
8
"
SEE SCH.
8"
6'
-
4
"
2"
2'
-
6
"
2"
±
9
'
-
1
0
"
2"2'-8"2"6'-0"2"2'-8"2"
± 12'-0"
BATO MATCH (E)
±
4
'
-
8
"
±
2
'
-
4
"
2'-0"2'-0"2'-0"
± 6'-0"
DOOR
NUMBER DOOR TYPE FRAME TYPE DESCRIPTION WIDTH HEIGHT
GLASS TYPE HEAD
DETAIL JAMB DETAIL
THRESHOLD/SILL
DETAIL HARDWARE REMARKS
Exterior
E1 A A ALUMINUM STOREFRONT 6' - 0" 7' - 0"1
E2 B B ALUMINUM CLAD WOOD DOOR 3' - 0" 7' - 0"3
E3 C B ALUMINUM CLAD WOOD DOOR 3' - 0" 7' - 0"4
E4 D N/A OVERHEAD GARAGE DOOR 10' - 0" 7' - 0"12
E5 B B ALUMINUM CLAD WOOD DOOR 3' - 0" 7' - 0"3
Interior
101 E A ALUMINUM STOREFRONT 6' - 0" 7' - 0"2
102 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"8
104 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"9
106 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"10 1
107 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
108 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"9 1
109 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"9 1
110 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
111 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
113 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
114 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
115 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
116 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
117 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"9 1
118 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"10
119 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"10
121 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
122 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
123 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
124 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"5
126 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
127 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"7 1
128 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"11 1
131 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"11
133 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"6
134 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"6
142 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"5
144 F C COMPOSITE DOOR W/ WOOD FRAME 3' - 0" 6' - 8"6
GL. 1 CLEAR ANNEALED FLOAT GLASS
GL. 2 CLEAR FULLY TEMPERED FLOAT GLASS
GL. 3 LOW-E-COATED, TINTED INSULATING GLASS
GL. 4 LOW-E-COATED, TINTED INSULATING GLASS
GL. 5 LOW-E-COATED, TINTED INSULATING GLASS
GLASS TYPES
1. FIELD VERIFY ALL ROUGH OPENINGS PRIOR TO FABRICATION OF DOOR & WINDOW
FRAMES.
2. PROVIDE SEALANT ENTIRE PERIMETER OF ALL DOOR & WINDOW FRAMES, BOTH SIDES.
3. PROVIDE ADEQUATE BARRIER AGAINST CORROSION BETWEEN DIFFERENT TYPES OF
MATERIALS THAT MAY COME INTO CONTACT.
4. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE FOR WALL & FLOOR FINISHES.
GENERAL NOTES
DOOR SCHEDULE
WINDOW TYPES
DOOR TYPES
DOOR FRAME TYPES
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
4
0
P
M
A10.1
DOOR &
WINDOW
SCHEDULES
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1. PROVIDE HOOK ON BACK OF DOOR
REMARKS
ADD. NO.
10/09/2019
1
CLARIFICATION: STOREFRONTS PROPOSED AS NON-THERMALLY BROKEN TRULITE
SYSTEM W/ 0.41 U-FACTOR
PR NO.
1/06/2020
3
no. description date
1 ADDENDUM #1 10/09/2019
8 PR #3 1/06/2020
9 PR #5 01/29/2020
PR NO.
01/29/2020
5
4
A3.1
1
1
AA
B
C
2
2 3
3
DD
4
4 5
53
A3.1
1
A3.1
2
A3.1
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) OPERATORY
(E)
(E) OPERATORYOPERATORY
137
OPERATORY
136
(E)
(E) IT
EXAM
138
(E)
(E) EXAM
(E)
(E) XRAY
ELEC
132
RESTROOM
128
(E)
(E) PROCEDURE
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) EXAM
(E)
(E) RECEPTION
(E)
(E) PHARMACY
(E)
(E) WAITING/RECEPTION
(E)
(E) STORAGE
(E)
(E) HALL
(E)
(E) CORR.
EXAM
139
OPERATORY
140
(E)
(E) LAB
(E)
(E) RESTROOM
(E)
(E) RESTROOM
(E)
(E) KID ROOM
CONFERENCE
119
BREAKROOM
118
RESTROOM
117
OFFICE
116
OFFICE
114
OFFICE
109
OFFICE
107
OFFICE
127
PLAY
THERAPY
106
MECH/ELEC
124RESTROOM
108
OFFICE
110
OFFICE
123
OFFICE
122
OFFICE
113
OFFICE
115
OFFICE
121
OFFICE
126
STORAGE
141
MEDICAL
STORAGE
133
DENTAL
STORAGE
134
CORR
131
LAB STORAGE
130
LAB
129
CORR
135
12' - 0"C1
9' - 0"C1
9' - 0"C1
9' - 0"C1
9' - 0"C19' - 0"C1
9' - 0"C19' - 0"C1
9' - 0"C1
9' - 0"C1 9' - 0"C1
9' - 0"C19' - 0"C1
9' - 0"C1
10' - 0"C1
12' - 0"C1
9' - 0"C1
VESTIBULE
101
OFFICE
111
WAITING
102
MECH
142
9' - 0"C1
9' - 0"C1
RECEPTION
105
TOILET
104
VEST.
103
9' - 0"C1
10' - 0"C1
CORR.
112
CORR.
120
CORR.
125
1
A5.1
________
1
A5.1
________
2
A5.1
________
3
A5.1
________
4
A5.1
________
5
A5.1
________
9' - 0"C1
0795002
A11.1
_____
2
A11.1
_____2
A11.1
_____
8' - 0"C2
8' - 0"C3
8' - 0"C2
8' - 0"C2
14' - 8"C5 STRUCT
9' - 0"C5
9' - 0"C3
9' - 0"C5
9' - 0"C5
9' - 0"C3
9' - 0"C5
9' - 0"C3
8' - 0"C3
9' - 0"C5
9' - 0"C3
9' - 0"C5
9' - 0"C5
9' - 0"C5 9' - 0"C5
EXIST.
EXIST.
9' - 0"C3 EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
EXIST.
9' - 0"C5EXIST.EXIST.EXIST.
8' - 0"C3 EXIST.
EXIST.
EXIST.
EXIST.
8' - 0"C3 EXIST.
079500
2
A4.2
_____
5
A4.2
_____
RFI NO.
1/13/2020
7
PR NO.
01/29/2020
5
(E)
DENTAL RECEPTION
9' - 0"C5 9' - 0"C5
9' - 0"C5
DENTAL
WAITING
144
HANGER WIRE
MAIN TEE
STRUCTURE
SPLAY WIRE SECURED
TO STRUCTURE
SPLAYED WIRE BRACING CONSISTS OF SETS OF FOUR 12 GAGE WIRES, ALL ATTACHED TO THE MAIN BEAM WITHIN 2"
OF A CROSS TEE/MAIN BEAM INTERSECTION. THESE WIRES ARE TO BE ARRAYED 90 DEGREES FROM ONE ANOTHER
AND MAY BE NO MORE THAN 45 DEGREES FROM HORIZONTAL. A VERTICAL POST OR STRUT, CAPABLE OF RESISTING
THE LOAD IMPOSED BY SEISMIC FORCES ACTING ON THE SPLAYED WIRES, IS TO BE ATTACHED TO THE MAIN AT THE
CENTER OF THE WIRE ARRAY. THE FIRST BRACING LOCATION IS TO BE LOCATED AT THE CROSS TEE/MAIN BEAM
INTERSECTION NOT MORE THAN SIX FEET FROM THE PERIMETER OF THE GRID IN EACH DIRECTION. THE BRACING
PATTERN IS TO BE REPEATED EVERY 12 FEET IN EACH DIRECTION.
SUSPENDED ACT CEILING
HEADER
5/8" G.W.B. OVER METAL STUD
6"
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
TUBULAR SKYLIGHT
C1 24" X 24" ACOUSTIC TILE & GRID SYSTEM - SEE SPECS
C2 EPOXY PAINTED, TEXTURED, TYPE 'X' GYPSUM WALL BOARD
C3 PAINTED, TEXTURED, TYPE 'X' GYPSUM WALL BOARD
C4 OPEN TO ABOVE
C5 (E) CEILING TO REMAIN, PAINT
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
1/
2
9
/
2
0
2
0
5
:
0
0
:
4
4
P
M
A11.1
REFLECTED
CEILING PLAN &
DETAILS
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A11.1
1 OVERALL REFLECTED CEILING PLAN
NORTH
1. CENTER LIGHT FIXTURES, ETC., IN CEILING TILES OR AS SHOWN.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
LIGHT GAUGE METAL FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C.
5. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
6. PROVIDE SEISMIC BRACING FOR ALL SUSPENDED CEILINGS - SEE DETAIL 3/A11.1
GENERAL NOTES
KEYED NOTES
079500 EXPANSION CONTROL
1" = 1'-0"A11.1
3 TYP. SEISMIC BRACING
1 1/2" = 1'-0"A11.1
2 HEADER DETAIL
CEILING LEGEND
CEILING TYPES
no. description date
9 PR #5 01/29/2020
11 RFI #7 1/13/2020
MARK
H
O
L
D
O
W
N
SHEARWALL END POST UNO ON PLANALTERNATE HOLDOWNSHEARWALL HOLDOWN SCHEDULE SIMPSON STHD14
(
2
)
2
x
S
T
U
D
S
N
/
A
A
JT JT
/
W
1
W
F
1
8
/
W
1
W
F
1
8
/
W
1
WF
1
8
6.
6.
AA
AA
1
1
4"
C
O
N
C
R
E
T
E
S
L
A
B
O
N
G
R
A
D
E
W/
#
3
A
T
1
8
"
O
.
C
.
E
A
C
H
W
A
Y
CE
N
T
E
R
E
D
I
N
S
L
A
B
T
H
I
C
K
N
E
S
S
OV
E
R
C
O
M
P
A
C
T
E
D
F
I
L
L
.
(S
E
E
G
S
N
)
10
1
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
2
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
1
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
'
-
5
"
88888
8
1 1
A
A
B
B
C
C
2 2
33
D
D
44
5 5
W
F
1
8
/
W
1
WF
1
8
/
W
1
W
F
1
8
4"
C
O
N
C
R
E
T
E
S
L
A
B
O
N
G
R
A
D
E
W/
#
3
A
T
1
8
"
O
.
C
.
E
A
C
H
W
A
Y
CE
N
T
E
R
E
D
I
N
S
L
A
B
T
H
I
C
K
N
E
S
S
OV
E
R
C
O
M
P
A
C
T
E
D
F
I
L
L
.
(S
E
E
G
S
N
)
11
1
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
11
0
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
11
0
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
(
F
I
E
L
D
V
E
R
I
F
Y
)
1
4
'
-
7
1
/
8
"
(F
I
E
L
D
V
E
R
I
F
Y
)
17
'
-
4
"
2
1
/
2
"
2
"
1
3
'
-
5
3
/
8
"
1
'
-
1
3
/
4
"
This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces . It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimension s, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans.PROJECT MANAGER:
C
A
D
O
P
E
R
A
T
O
R
:
JOB NO.:fax: 208.227.84051020 E. Lincoln Road Idaho Falls, ID 834016WUXFWXUDO(QJLQHHULQJ phone: 208.227.8404 FRQWDFW#IURVWVWUXFWXUDOFRPGTCDBPIF19-322SURMHFWGDWHUHYLVLRQV'UDZLQJVDQGVSHFLILFDWLRQVDVLQVWUXPHQWVRISURIHVVLRQDOVHUYLFHDUHDQGVKDOOUHPDLQWKHSURSHUW\RIWKHDUFKLWHFW7KHVHGRFXPHQWVDUHQRWWREHXVHGLQZKROHRULQSDUWIRUDQ\SURMHFWRUSXUSRVHVZKDWVRHYHUZLWKRXWWKHSULRUVSHFLILFZULWWHQDXWKRUL]DWLRQRI*3&$UFKLWHFWV3//&2ZQHUVKLS 8VHRI'RFXPHQWV VKHHW10DLQ6W6WH'ULJJV,GDKRZZZJSFDUFKLWHFWVFRP
3
0
6)281'$7,21 3/$1*5$1'3($.65(129$7,21 5(;%85*,'$+2
NO
R
T
H
WALL (W) SCHEDULE TYPE
M
A
T
E
R
I
A
L
T
H
I
C
K
N
E
S
S
VERTICAL REINFORCINGHORIZONTAL REINFORCING REMARKS W1
C
O
N
C
R
E
T
E
8
"
#
4
A
T
1
8
"
O
.
C
.
#
4
A
T
1
2
"
O
.
C
.
-
-
-
W2
M
A
S
O
N
R
Y
8
"
#
5
A
T
3
2
"
O
.
C
.
#
5
A
T
4
8
"
O
.
C
.
-
-
-
FOOTING SCHEDULE MARK
L
E
N
G
T
H
W
I
D
T
H
THICKN ESS REINFORCING
R
E
M
A
R
K
S
WF18
C
O
N
T
1
8
"
1
0
"
(
2
)
#
4
C
O
N
T
B
O
T
T
O
M
S
T
R
I
P
F
O
O
T
I
N
G
Keynotes 1
A
T
T
A
C
H
N
E
W
F
O
O
T
I
N
G
/
W
A
L
L
T
O
E
X
I
S
T
I
N
G
F
O
U
N
D
A
T
I
O
N
W
/
#4 x 24" LONG EPOXY DOWELS, MATCH FOOTING AND WALL HORIZONTAL BAR SPACING 8
I
N
F
I
L
L
B
E
T
W
E
E
N
E
X
I
S
T
I
N
G
B
U
I
L
D
I
N
G
S
,
S
E
E
T
Y
P
I
C
A
L
MASONRY INFILL WALL DETAIL AND COORDINATE W/ ARCHFOUNDATION PLAN NOTES A.
V
E
R
I
F
Y
A
L
L
D
I
M
E
N
S
I
O
N
S
W
I
T
H
A
L
L
A
R
C
H
I
T
E
C
T
U
R
A
L
DRAWINGS.B.
A
L
L
S
C
H
E
D
U
L
E
D
M
A
R
K
D
E
S
I
G
N
A
T
I
O
N
S
M
A
Y
N
O
T
NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT.C.
T
H
E
D
E
P
T
H
O
F
F
O
O
T
I
N
G
D
I
M
E
N
S
I
O
N
I
N
D
I
C
A
T
E
D
I
N
T
H
E
G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS.D.
.
W
A
L
L
S
W
I
T
H
S
O
L
I
D
L
I
N
E
S
D
E
S
I
G
N
A
T
E
D
STRUCTURAL (BEARING) WALLS.E.
.
W
A
L
L
S
W
I
T
H
D
A
S
H
E
D
L
I
N
E
S
D
E
S
I
G
N
A
T
E
NON-STRUCTURAL (NON-BEARING) WALLS..F.
.
,
,
,
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH..G.
.
,
,
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION..H.
W
1
,
W
2
,
E
T
C
.
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION.I.
W
F
1
8
,
W
F
2
4
,
E
T
C
.
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION.J.
A
L
L
E
X
T
E
R
I
O
R
W
A
L
L
S
S
H
A
L
L
B
E
C
O
N
S
T
R
U
C
T
E
D
W
I
T
H
TYPE "5" SHEARWALLS, UNO.K.
V
E
R
I
F
Y
E
X
A
C
T
S
I
Z
E
A
N
D
L
O
C
A
T
I
O
N
O
F
D
E
P
R
E
S
S
E
D
AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS.L.
F
O
R
S
I
D
E
W
A
L
K
A
N
D
L
A
N
D
I
N
G
L
O
C
A
T
I
O
N
S
,
S
E
E
ARCHITECTURAL DRAWINGS.565 AB
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
FO
U
N
D
A
T
I
O
N
P
L
A
N
7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES.6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS.5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL...4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE.3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS.2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM.1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS.NOTES:SHEARWALL TYPE SCHEDULE MARK
S
H
E
A
T
H
I
N
G
M
A
T
E
R
I
A
L
E
D
G
E
N
A
I
L
I
N
G
F
I
E
L
D
N
A
I
L
I
N
G
B
O
T
T
O
M
P
L
A
T
E
A
T
T
A
C
H
M
E
N
T
5
7
/
1
6
"
A
P
A
R
A
T
E
D
SHEATHING (BLOCKED)ONE SIDE OF WALL8d COMMON AT 6" O.C.8d COMMON AT 12" O.C.CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C.CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C.WOOD: 16d STAGGERED AT 6" O.C.6.
7
/
1
6
"
A
P
A
R
A
T
E
D
SHEATHING (BLOCKED)ONE SIDE OF WALL8d COMMON AT 4" O.C.8d COMMON AT 12" O.C.CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C.CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C.WOOD: 16d STAGGERED AT 4" O.C.QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
Jan. 23, 2020
PR
0
5
QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
PR 05 1/23/2020
JT
B1
P1
P1
WJ
1
6.
6.
7/
1
6
"
A
P
A
R
A
T
E
D
R
O
O
F
S
H
E
A
T
H
I
N
G
W/
8
d
C
O
M
M
O
N
N
A
I
L
S
A
T
6
"
O
.
C
.
A
T
PA
N
E
L
E
D
G
E
S
/
B
O
U
N
D
A
R
Y
A
N
D
A
T
12
"
O
.
C
.
I
N
T
H
E
F
I
E
L
D
.
10
5
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
3
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
3
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
10
4
S3
.
0
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
4
3
5
22
4
4
9
6
6
4 88
8
4 88
8
7
7
1 1
A
A
B
B
C
C
2 2
33
D
D
44
5 5
7
11 11
11
11 10
10
11
6
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
11
2
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
11
3
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
W8
x
1
8
11
5
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
11
4
S3
.
1
_____
_
_
_
_
_
_
_
_____
_
_
_
_
_
_
_
W
2
W2
W
2
5/
8
"
A
P
A
R
A
T
E
D
F
I
R
E
T
R
E
A
T
E
D
RO
O
F
S
H
E
A
T
H
I
N
G
W
/
#
8
S
C
R
E
W
S
AT
6
"
O
.
C
.
A
T
P
A
N
E
L
E
D
G
E
S
/
BO
U
N
D
A
R
Y
A
N
D
A
T
1
2
"
O
.
C
.
I
N
T
H
E
FI
E
L
D
.
A
T
2
4
"
O
.
C
.
(2
)
6
0
0
S
1
6
2
-
5
4
(
B
A
C
K
-
T
O
-
B
A
C
K
)
M
L
1
M
L
1
MASONRY LINTEL (L) SCHEDULE MARK ML1SIZE 16" DEEPREINFORCING (1) #5 TOP AND BOTTOM This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces . It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimension s, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans.PROJECT MANAGER:
C
A
D
O
P
E
R
A
T
O
R
:
JOB NO.:fax: 208.227.84051020 E. Lincoln Road Idaho Falls, ID 834016WUXFWXUDO(QJLQHHULQJ phone: 208.227.8404 FRQWDFW#IURVWVWUXFWXUDOFRPGTCDBPIF19-322SURMHFWGDWHUHYLVLRQV'UDZLQJVDQGVSHFLILFDWLRQVDVLQVWUXPHQWVRISURIHVVLRQDOVHUYLFHDUHDQGVKDOOUHPDLQWKHSURSHUW\RIWKHDUFKLWHFW7KHVHGRFXPHQWVDUHQRWWREHXVHGLQZKROHRULQSDUWIRUDQ\SURMHFWRUSXUSRVHVZKDWVRHYHUZLWKRXWWKHSULRUVSHFLILFZULWWHQDXWKRUL]DWLRQRI*3&$UFKLWHFWV3//&2ZQHUVKLS 8VHRI'RFXPHQWV VKHHW10DLQ6W6WH'ULJJV,GDKRZZZJSFDUFKLWHFWVFRP
3
0
6522))5$0,1*3/$1*5$1'3($.65(129$7,21 5(;%85*,'$+2
NO
R
T
H
POST (P) SCHEDULE MARK
S
I
Z
E
S
P
E
C
I
E
S
A
N
D
G
R
A
D
E
C
O
N
N
E
C
T
I
O
N
P1
(
2
)
2
x
6
D
F
#
2
WOOD JOIST (WJ) SCHEDULE MARK
J
O
I
S
T
F
A
C
E
M
O
U
N
T
H
A
N
G
E
R
T
O
P
F
L
A
N
G
E
H
A
N
G
E
R
WJ1
2
x
8
A
T
1
6
"
O
.
C
.
-
-
-
P
F
2
8
B
BEAM (B)SCHEDULE MARK
S
I
Z
E
B1
(
2
)
1
3
/
4
x
9
1
/
2
L
V
L
Keynotes 2
N
E
W
W
I
N
D
O
W
O
P
E
N
I
N
G
I
N
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
,
S
E
E
DETAIL 107 FOR REINFORCING REQUIREMENT 3
N
E
W
W
I
N
D
O
W
O
P
E
N
I
N
G
I
N
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
,
S
E
E
DETAIL 109 FOR REINFORCING REQUIREMENT 4
N
E
W
D
O
O
R
O
P
E
N
I
N
G
I
N
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
,
S
E
E
DETAIL 106 FOR REINFORCING REQUIREMENT 5
N
E
W
O
P
E
N
I
N
G
I
N
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
,
S
E
E
D
E
T
A
I
L
1
0
8
FOR REINFORCING REQUIREMENT 6
E
N
D
S
T
U
D
T
O
B
E
P
R
E
S
S
U
R
E
T
R
E
A
T
E
D
A
N
D
A
T
T
A
C
H
E
D
T
O
THE EXISTING MASONRY WALL W/ 5/8" DIA x 6' LONG TITEN HD AT 24" O.C.7
I
N
F
I
L
L
E
X
I
S
T
I
N
G
D
O
O
R
O
P
E
N
I
N
G
,
S
E
E
T
Y
P
I
C
A
L
M
A
S
O
N
R
Y
INFILL WALL DETAIL 8
I
N
F
I
L
L
B
E
T
W
E
E
N
E
X
I
S
T
I
N
G
B
U
I
L
D
I
N
G
S
,
S
E
E
T
Y
P
I
C
A
L
MASONRY INFILL WALL DETAIL AND COORDINATE W/ ARCH 9
I
N
F
I
L
L
E
X
I
S
T
I
N
G
O
V
E
R
H
E
A
D
D
O
O
R
O
P
E
N
I
N
G
A
N
D
ACCOMMODATE NEW WINDOW OPENING, SEE TYPICAL MASONRY INFILL WALL DETAIL, STEEL ANGLE REINFORCING IS NOT REQUIRED (CONTRACTOR TO PROVIDE TEMPORARY SHORING FOR WINDOW AS REQUIRED)10
A
T
E
N
D
O
F
W
A
L
L
P
R
O
V
I
D
E
(
2
)
#
5
F
U
L
L
-
H
E
I
G
H
T
V
E
R
T
I
C
A
L
BARS IN LAST CELL, PROVIDE #4 HORIZONTAL HAIRPIN (24"LONG LEGS) AND ALL REINFORCED BOND BEAMS, SEE DETAIL 115 11
(
1
)
#
5
F
U
L
L
-
H
E
I
G
H
T
V
E
R
T
I
C
A
L
J
A
M
B
B
A
R
S
565ROOF FRAMING PLAN NOTES A.
V
E
R
I
F
Y
A
L
L
D
I
M
E
N
S
I
O
N
S
W
I
T
H
A
L
L
A
R
C
H
I
T
E
C
T
U
R
A
L
DRAWINGS.B.
A
L
L
S
C
H
E
D
U
L
E
D
M
A
R
K
D
E
S
I
G
N
A
T
I
O
N
S
M
A
Y
N
O
T
NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT.C.
.
W
A
L
L
S
W
I
T
H
S
O
L
I
D
L
I
N
E
S
D
E
S
I
G
N
A
T
E
D
STRUCTURAL (BEARING) WALLS.D.
.
W
A
L
L
S
W
I
T
H
D
A
S
H
E
D
L
I
N
E
S
D
E
S
I
G
N
A
T
E
NON-STRUCTURAL (NON-BEARING) WALLS..E.
.
,
,
,
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH.F.
I
F
D
O
U
B
L
E
T
O
P
P
L
A
T
E
I
S
N
O
T
C
H
E
D
,
S
T
E
P
P
E
D
O
R
BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY.G.
T
Y
P
I
C
A
L
B
E
A
R
I
N
G
W
A
L
L
F
R
A
M
I
N
G
S
H
A
L
L
B
E
(
2
)
2
x
6
STUDS AT 16" O.C. UNO.I.
B
1
,
B
2
,
E
T
C
.
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
B
E
A
M
O
R
HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION.J.
W
J
1
,
W
J
2
,
E
T
C
.
-
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
W
O
O
D
JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION.K.
P
1
,
P
2
,
E
T
C
.
A
S
S
H
O
W
N
O
N
P
L
A
N
I
N
D
I
C
A
T
E
S
A
W
O
O
D
POST. SEE POST SCHEDULE FOR MORE INFORMATION.T.
T
I
E
E
A
C
H
R
O
O
F
J
O
I
S
T
A
T
B
E
A
R
I
N
G
L
O
C
A
T
I
O
N
S
W
I
T
H
(
1
)
H2.5A CLIP, UNO.Z.
A
L
L
E
X
T
E
R
I
O
R
W
A
L
L
S
S
H
A
L
L
B
E
C
O
N
S
T
R
U
C
T
E
D
W
I
T
H
TYPE "5" SHEARWALLS, UNO.7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES.6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS.5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL...4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE.3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS.2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM.1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS.NOTES:SHEARWALL TYPE SCHEDULE MARK
S
H
E
A
T
H
I
N
G
M
A
T
E
R
I
A
L
E
D
G
E
N
A
I
L
I
N
G
F
I
E
L
D
N
A
I
L
I
N
G
B
O
T
T
O
M
P
L
A
T
E
A
T
T
A
C
H
M
E
N
T
5
7
/
1
6
"
A
P
A
R
A
T
E
D
SHEATHING (BLOCKED)ONE SIDE OF WALL8d COMMON AT 6" O.C.8d COMMON AT 12" O.C.CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C.CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C.WOOD: 16d STAGGERED AT 6" O.C.6.
7
/
1
6
"
A
P
A
R
A
T
E
D
SHEATHING (BLOCKED)ONE SIDE OF WALL8d COMMON AT 4" O.C.8d COMMON AT 12" O.C.CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C.CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C.WOOD: 16d STAGGERED AT 4" O.C.
SC
A
L
E
:
1
/
8
"
=
1
'
-
0
"
RO
O
F
F
R
A
M
I
N
G
P
L
A
N
QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
WALL (W) SCHEDULE TYPE
M
A
T
E
R
I
A
L
T
H
I
C
K
N
E
S
S
VERTICAL REINFORCINGHORIZONTAL REINFORCING REMARKS W1
C
O
N
C
R
E
T
E
8
"
#
4
A
T
1
8
"
O
.
C
.
#
4
A
T
1
2
"
O
.
C
.
-
-
-
W2
M
A
S
O
N
R
Y
8
"
#
5
A
T
3
2
"
O
.
C
.
#
5
A
T
4
8
"
O
.
C
.
-
-
-
Jan. 23, 2020
PR
0
5
QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
PR 05 1/23/2020
KEYNOTES:3"CLR3"CLR2'-6"LAP MIN 2'-0"LAP MIN1.MASONRY WALL, SEE PLAN 2. #5 DOWEL TO MATCH VERTICAL WALL REINFORCING 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.
M
I
N
I
M
U
M
F
O
O
T
I
N
G
D
E
P
T
H
,
S
E
E
GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 8 7 6812543 KEYNOTES:2'-6"LAP MIN 10"8"6"1'-6"1.
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
2.#5 x 48" LONG EPOXY DOWEL AT 18" O.C.3.EXISTING CONCRETE SLAB ON GRADE 4.EXISTING FOUNDATION SYSTEM 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.
C
O
N
C
R
E
T
E
F
O
O
T
I
N
G
,
S
E
E
P
L
A
N
7.CONCRETE SLAB ON GRADE, SEE PLAN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.MASONRY WALL, SEE PLAN 51273 48869
KE
Y
N
O
T
E
S
:
1.
F
R
T
R
O
O
F
S
H
E
A
T
H
I
N
G
,
S
E
E
P
L
A
N
2.
S
/
H
G
A
M
1
0
C
L
I
P
A
T
E
A
C
H
J
O
I
S
T
3.
BO
U
N
D
A
R
Y
F
A
S
T
E
N
E
R
,
S
E
E
P
L
A
N
4.
CO
N
T
3
3
M
I
L
F
A
S
C
I
A
T
R
A
C
K
W
/
#
1
0
SC
R
E
W
S
A
T
E
A
C
H
J
O
I
S
T
,
T
O
P
&
BO
T
T
O
M
5.
MA
S
O
N
R
Y
W
A
L
L
,
S
E
E
P
L
A
N
6.
6
"
L
O
N
G
3
3
M
I
L
T
R
A
C
K
P
I
E
C
E
,
AT
T
A
C
H
T
O
J
O
I
S
T
W
/
(
4
)
#
1
0
SC
R
E
W
S
7.
R
O
O
F
J
O
I
S
T
,
S
E
E
P
L
A
N
3
4
1
7
5
2
6
KE
Y
N
O
T
E
S
:
1.
F
R
T
R
O
O
F
S
H
E
A
T
H
I
N
G
,
S
E
E
P
L
A
N
2.
BO
U
N
D
A
R
Y
F
A
S
T
E
N
E
R
,
S
E
E
P
L
A
N
3.
MA
S
O
N
R
Y
W
A
L
L
,
S
E
E
P
L
A
N
4.
C
O
N
T
3
3
M
I
L
L
E
D
G
E
R
T
R
A
C
K
W
/
#
1
0
SC
R
E
W
S
A
T
E
A
C
H
B
L
O
C
K
,
T
O
P
&
BO
T
T
O
M
5.
S
/
H
G
A
M
1
0
C
L
I
P
A
T
1
6
"
O
.
C
.
6.
6
0
0
S
1
6
2
-
5
4
B
L
O
C
K
A
T
1
6
"
O
.
C
.
7.
RO
O
F
J
O
I
S
T
,
S
E
E
P
L
A
N
1
2
3
4
5
6
7
KE
Y
N
O
T
E
S
:
1.
F
R
T
R
O
O
F
S
H
E
A
T
H
I
N
G
,
S
E
E
P
L
A
N
2.
10
d
x
1
1 /2 "
L
O
N
G
N
A
I
L
S
S
T
4
"
O
.
C
.
3.
E
X
I
S
T
I
N
G
R
O
O
F
S
T
R
U
C
T
U
R
E
4.
CO
N
T
2
x
W
/
5 /8 "
D
I
A
T
H
R
E
A
D
E
D
ST
U
D
S
W
/
W
A
S
H
E
R
A
T
3
2
"
O
.
C
.
(C
O
U
N
T
E
R
S
I
N
K
A
S
R
E
Q
U
I
R
E
D
)
5.
ST
E
E
L
B
E
A
M
,
S
E
E
P
L
A
N
6.
S
I
M
P
S
O
N
S
/
H
J
C
T
H
A
N
G
E
R
7.
RO
O
F
J
O
I
S
T
,
S
E
E
P
L
A
N
8.
LT
P
4
C
L
I
P
A
T
2
4
"
O
.
C
.
9.
A3
4
C
L
I
P
A
T
2
4
"
O
.
C
.
10
.
S
O
L
I
D
B
L
O
C
K
A
S
R
E
Q
U
I
R
E
D
1
2
3
4
5
6
7
9 8
10
NO
T
E
:
KE
Y
N
O
T
E
S
:
3/
1
6
3
3
3/
1
6
A.
O
T
H
E
R
F
R
A
M
I
N
G
N
O
T
S
H
O
W
N
F
O
R
CL
A
R
I
T
Y
1.
ST
E
E
L
B
E
A
M
,
S
E
E
P
L
A
N
2.
HA
I
R
P
I
N
A
R
O
U
N
D
H
E
A
D
E
D
S
T
U
D
S
AN
D
V
E
R
T
I
C
A
L
B
A
R
S
,
S
E
E
P
L
A
N
3.
M
A
S
O
N
R
Y
W
A
L
L
,
S
E
E
P
L
A
N
4.
VE
R
T
I
C
A
L
B
A
R
S
,
S
E
E
P
L
A
N
5.
8"
H
O
R
I
Z
O
N
T
A
L
B
O
N
D
B
E
A
M
W
/
(
1
)
#5
A
T
B
E
A
R
I
N
G
E
L
E
V
A
T
I
O
N
6.
1 /2 "
x
8
"
x
0
'
-
8
"
B
E
A
R
I
N
G
P
L
A
T
E
W
/
(
2
)
5 /8 "
D
I
A
x
6
"
L
O
N
G
H
E
A
D
E
D
S
T
U
D
S
1
4
3
5
2
6
KE
Y
N
O
T
E
S
:
1.
F
R
T
R
O
O
F
S
H
E
A
T
H
I
N
G
,
S
E
E
P
L
A
N
2.
10
d
N
A
I
L
S
A
T
4
"
O
.
C
.
3.
EX
I
S
T
I
N
G
R
O
O
F
S
T
R
U
C
T
U
R
E
4.
CO
N
T
3
3
M
I
L
T
R
A
C
K
W
/
#
1
0
SC
R
E
W
S
A
T
E
A
C
H
B
L
O
C
K
,
T
O
P
&
BO
T
T
O
M
A
N
D
#
1
0
S
C
R
E
W
A
T
4
"
O
.
C
.
IN
T
O
E
X
I
S
T
I
N
G
F
R
A
M
I
N
G
5.
E
X
I
S
T
I
N
G
M
A
S
O
N
R
Y
W
A
L
L
6.
MA
S
O
N
R
Y
W
A
L
L
,
S
E
E
P
L
A
N
7.
S/
H
G
A
M
1
0
C
L
I
P
A
T
2
4
"
O
.
C
.
8.
6
0
0
S
1
6
2
-
5
4
B
L
O
C
K
A
T
2
4
"
O
.
C
.
9.
R
O
O
F
J
O
I
S
T
,
S
E
E
P
L
A
N
1
2
8
9
3
5
7 6
4
This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces . It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimension s, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans.PROJECT MANAGER:
C
A
D
O
P
E
R
A
T
O
R
:
JOB NO.:fax: 208.227.84051020 E. Lincoln Road Idaho Falls, ID 834016WUXFWXUDO(QJLQHHULQJ phone: 208.227.8404 FRQWDFW#IURVWVWUXFWXUDOFRPGTCDBPIF19-322SURMHFWGDWHUHYLVLRQV'UDZLQJVDQGVSHFLILFDWLRQVDVLQVWUXPHQWVRISURIHVVLRQDOVHUYLFHDUHDQGVKDOOUHPDLQWKHSURSHUW\RIWKHDUFKLWHFW7KHVHGRFXPHQWVDUHQRWWREHXVHGLQZKROHRULQSDUWIRUDQ\SURMHFWRUSXUSRVHVZKDWVRHYHUZLWKRXWWKHSULRUVSHFLILFZULWWHQDXWKRUL]DWLRQRI*3&$UFKLWHFWV3//&2ZQHUVKLS 8VHRI'RFXPHQWV VKHHW10DLQ6W6WH'ULJJV,GDKRZZZJSFDUFKLWHFWVFRP
3
0
6'(7$,/6*5$1'3($.65(129$7,21 5(;%85*,'$+2 QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
SCALE: NTS 110 MASONRY WALL AT FOUNDATION SCALE: NTS 111 MASONRY WALL AT FOUNDATION
SC
A
L
E
:
N
T
S
11
2
RO
O
F
J
O
I
S
T
A
T
M
A
S
O
N
R
Y
W
A
L
L
SC
A
L
E
:
N
T
S
11
3
RO
O
F
J
O
I
S
T
A
T
M
A
S
O
N
R
Y
W
A
L
L
SC
A
L
E
:
N
T
S
11
4
RO
O
F
J
O
I
S
T
A
T
S
T
E
E
L
B
E
A
M
SC
A
L
E
:
N
T
S
11
5
ST
E
E
L
B
E
A
M
A
T
M
A
S
O
N
R
Y
W
A
L
L
SC
A
L
E
:
N
T
S
11
6
RO
O
F
J
O
I
S
T
A
T
M
A
S
O
N
R
Y
W
A
L
L
Jan. 23, 2020 PR 05 PR 05
PR
0
5
PR
0
5
PR
0
5
PR
0
5
PR
0
5
QR
G
H
V
F
U
L
S
W
L
R
Q
G
D
W
H
PR 05 1/23/2020
RE
F
.
1 1
A
A
B
B
C
C
2 2
33
D
D
44
5 5
(E
)
K
I
D
R
O
O
M
A2
4
9
(E
)
W
A
I
T
I
N
G
/
R
E
C
E
P
T
I
O
N
A2
3
3
(E
)
S
T
O
R
A
G
E
A2
3
5
(E
)
E
X
A
M
A2
2
7
(E
)
E
X
A
M
A2
2
6
(E
)
P
R
O
C
E
D
U
R
E
A2
2
5
LA
B
12
9
(E
)
N
U
R
S
E
S
T
A
T
I
O
N
A2
3
0
(E
)
R
E
C
E
P
T
I
O
N
A2
3
1
(E
)
R
E
S
T
R
O
O
M
A2
4
7
(E
)
P
H
A
R
M
A
C
Y
A2
3
2
(E
)
E
X
A
M
A2
2
9
(E
)
E
X
A
M
A2
1
6
EX
A
M
13
9
OP
E
R
A
T
O
R
Y
14
0
(E
)
L
A
B
A2
4
4
(E
)
H
A
L
L
A2
1
5
(E
)
E
X
A
M
A2
2
8
EX
A
M
13
8
(E
)
C
O
R
R
.
A2
4
0
(E
)
O
P
E
R
A
T
O
R
Y
A2
0
8
(E
)
O
P
E
R
A
T
O
R
Y
A2
0
7
(E
)
O
P
E
R
A
T
O
R
Y
A2
0
6
(E
)
O
P
E
R
A
T
O
R
Y
A2
0
5
ST
O
R
A
G
E
14
1
ME
C
H
14
2
OP
E
R
A
T
O
R
Y
13
7
OP
E
R
A
T
O
R
Y
13
6
DE
N
T
A
L
S
T
O
R
A
G
E
13
4
(E
)
I
T
A2
1
2
ME
D
I
C
A
L
S
T
O
R
A
G
E
13
3
(E
)
X
R
A
Y
A2
1
8
EL
E
C
13
2
(E
)
H
A
L
L
A2
3
6
CO
R
R
13
1
LA
B
S
T
O
R
A
G
E
13
0
RE
S
T
R
O
O
M
12
8
OF
F
I
C
E
12
7
OF
F
I
C
E
12
6
PL
A
Y
T
H
E
R
A
P
Y
10
6
ME
C
H
/
E
L
E
C
12
4
RE
S
T
R
O
O
M
10
8
RE
C
E
P
T
I
O
N
10
5
OF
F
I
C
E
10
7
OF
F
I
C
E
10
9
OF
F
I
C
E
11
1
OF
F
I
C
E
11
0
OF
F
I
C
E
12
3
OF
F
I
C
E
12
2
OF
F
I
C
E
12
1
OF
F
I
C
E
11
3
OF
F
I
C
E
11
5
CO
N
F
E
R
E
N
C
E
11
9
BR
E
A
K
R
O
O
M
11
8
RE
S
T
R
O
O
M
11
7
OF
F
I
C
E
11
6
OF
F
I
C
E
11
4
CD
-
1
27
5
CD
-
1
27
5
CD
-
1
15
0
CD
-
2
15
0
CD
-
3
10
0
CD
-
1
17
5
CD
-
1
17
5
CD
-
1
17
5
CD
-
1
17
5
CD
-
1
17
5
CD
-
3
10
0
CD
-
3
10
0
CD
-
2
15
0
CD
-
1
15
0
CD
-
1
25
0
CD
-
1
25
0
CD
-
1
15
0
CD
-
1
15
0
CD
-
1
15
0
CD
-
1
15
0
CD
-
1
15
0
CD
-
1
15
0
CD
-
1
35
0
CD
-
1
35
0
CD
-
1
30
0
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
1
RG
-
2
RG
-
3
2
EF 44
EF 3
4
EF 1
4
EF 2
4
T
1
8
"
x
1
4
"
1
8
"
x
1
0
"
1
8
"
x
1
0
"
1
8
"
x
1
4
"
1
8
"
x
1
0
"
18
"
x
1
0
"
1
8
"
x
1
4
"
12
"
x
1
2
"
12
"
x
1
0
"
1
8
"
x
1
2
"
16
"
x
1
2
"
12
"
x
6
"
18
"
x
1
4
"
3
3
3
3
3
3
3
3
3
3
3
3 2
2
2
RT 3
1
RT 2
1
RT 1
1
HD
HD
HD
HD
HDHD
HD
HDHDHD
HD
HDHD
HD
HD
HD
HD
HD
HD
HD
HD
HD
HD HD HD
HD
HD
WA
I
T
I
N
G
10
2
10
"
ø
6"
ø
10
"
ø
10
"
ø
10
"
ø
10
"
ø
10
"
ø
10
"
ø
10
"
ø
10
"
ø
18
"
x
1
2
"
12
"
x
1
0
"
12
"
x
6
"
12
"
x
1
0
"
14
"
x
1
0
"
CD
-
1
10
0
12
"
x
1
0
"
T
12
"
x
1
0
"
RG
-
1
3
RG
-
1
3
2
12
"
x
6
"
T
18
"
x
1
4
"
RG
-
1
3 12
"
x
3
"
12
"
x
1
0
"
RG
-
2
RG
-
2
12
"
x
1
2
"
RG
-
1
3
18
"
x
1
6
"
1
8
"
x
2
"
1
8
"
x
1
4
"
2
RG
-
1
3 RG
-
1
3
RT
-
1
RT
-
3
RT
-
2
12
"
x
1
0
"
7
CD
-
4
25
0
15
0
CF
M
7 15
0
CF
M
7 15
0
CF
M
7 15
0
CF
M
7 25
0
CF
M
7 15
0
CF
M
7 15
0
CF
M
7 12
0
CF
M
7 20
0
CF
M
7 25
0
CF
M
9
10
"
ø
8
8
PR
O
V
I
D
E
N
E
W
P
R
E
S
S
U
R
E
RE
G
U
L
A
T
O
R
I
N
E
X
I
S
T
I
N
G
G
A
S
L
I
N
E
ON
R
O
O
F
S
E
R
V
I
N
G
F
I
R
E
P
L
A
C
E
.
FI
E
L
D
V
E
R
I
F
Y
E
X
A
C
T
P
I
P
E
S
I
Z
E
A
N
D
MA
T
C
H
R
E
G
U
L
A
T
O
R
W
I
T
H
P
I
P
E
.
PROVIDE NEW PRESSURE REGULATOR IN EXISTING GAS LINE ON ROOF SERVING FIRE PLACE. FIELD VERIFY EXACT PIPE SIZE AND MATCH REGULATOR WITH PIPE.
T
EX
I
S
T
I
N
G
T
H
E
R
M
O
S
T
A
T
T
O
R
E
M
A
I
N
T 5 5 9 /2 7 /1 9GD A H W5762TA ENAYWSDDTEO C .I S D UFSREPROFNESGIEERTAISONLEEEKSOIREEN Engineered Systems Associates ESA JOB NUMBER 19060 project:date:revisionsDrawings and specifications, as instruments of professional service are and shall remain the prope rty of the architect. These documents are not to be us ed in whole or in part for any project or purposes whatsoever, without the prior specific written authorization of GPC Architects PLLC.Ownership & Use of Documents sheet:18 N. Main St., Ste. 200 Driggs, Idaho 83422 208.354.8036 www.gpcarchitects.com M1.1MECHANICALFLOOR PLAN190609/26/2019GRAND PEAKS RENOVATION REXBURG, IDAHOPLAN NOTES:1
ME
C
H
A
N
I
C
A
L
F
L
O
O
R
P
L
A
N
SC
A
L
E
:
1
/
8
"
=
1
'
-0"
NO
R
T
H
PROVIDE AND INSTALL NEW ROOF MOUNTED EQUIPMENT AS S PECIFIED. MOUNT OVER EXISTING SKYLIGHT OPENING SO THAT SUPPLY AND RETURN AIR DUCTS WILL PASS DOWN THROUGH EXISTING OPENINGS. CONTRACTOR TO FIELD VERIFY EXACT SIZES AND LOCATIONS OF EXISTING OPENINGS. MOUNT EQUIPMENT ON NEW ROOF CURB. REFER TO DETAIL J/M3.1 FOR TYPICAL CURB INSTALLATIO N.EXISTING SKYLIGHT OPENING THRU CONCRETE TEE ROOF. R EFER TO ARCHITECTURAL PLANS FOR PATCHING OF EXISTING OPENINGS. UTILIZE EX ISTING OPENINGS FOR ALL EXHAUST VENTS, PLUMBING VENTS, SUPPLY AND RETURN DU CTS, ETC. CONTRACTOR TO FIELD VERIFY EXACT SIZES AND LOCATIONS OF EXISTI NG OPENINGS. REFER TO ARCHITECTURAL PLANS FOR PATCHING EXISTING OPENINGS.PROVIDE AND INSTALL WALL MOUNTED RETURN GRILLE AS S PECIFIED. MOUNT GRILLE AT 6" ABOVE FLOOR AND CONNECT TO 12x3 (UN-LINED) DU CT IN WALL CAVITY. REFER TO DETAIL D/M3.1 FOR TYPICAL INSTALLATION.PROVIDE AND INSTALL CEILING MOUNTED EXHAUST FAN AS SPECIFIED. RUN 6" Dia. EXHAUST DUCT UP THRU EXISTING ROOF OPENING TO ROOF CAP. PROVIDE ROOF CURB AROUND DUCT AS REQUIRED BY MANUFACTURER.EXISTING ELECTRIC COVER HEATER ABOVE WINDOW AND WAL L MOUNTED THERMOSTAT TO REMAIN. PROTECT DURING CONSTRUCTION.EXISTING GAS FIRED FIRE PLACE, GAS PIPING, AND FLUE THRU ROOF TO REMAIN. PROTECT EQUIPMNET AND PIPING DURING CONSTRUCTION.EXISTING DUCTWORK AND CEILING DIFFUSERS TO REMAIN. RE-BALANCE EXISTING DIFFUSER TO CFM AS INDICATED.PROVIDE AND INSTALL NEW CEILING DIFFUSER AS SPECIFI ED. RUNNEW 10" Dia. DUCT THRU ROOF JOIST SPACE AND CONNECT TO EXISTING SUPPL Y AIR DUCT FROM EXISTING ROOF TOP UNIT. BALANCE TO CFM AS SHOWN.EXISTING ROOF TOP UNIT TO REMAIN. ALL ASSOCIATED D UCTWORK AND CONTROLS ARE TO REMAIN. RE-BALANCE EXISTING SYSTEM TO CMF A S INDICATED ATE EACH CEILING DIFFUSER FOR TOTAL OF 1980 CFM.2 3 4 no.
d
e
s
c
r
i
p
t
i
o
n
d
a
t
e
1
P
R
0
5
0
1
-
1
7
-
2
0
2
0
5 6 7 8 9 1 1
1 1
1
F
F
1
A
B
C
2 3
D
4 5
1
2
2
'A'
'DS-MAIN'
'B'
'C'
3
4
4 4
5
AIR
COMP.
DENTAL
VAC.
6
7
4
4
4
8
49
8
8
1
A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL
EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED.
WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR
NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C.
MAY UTILIZE THE EXISTING ROUGH-IN, ETC. IN LIEU OF INSTALLING
NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL
CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL
CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY
ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW
DEVICES AND COVERS.
B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS,
HOWEVER THE ABOVE INFORMATION APPLIES.
C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED
SWITCH/OUTLET/J-BOXES WHERE REQUIRED.
D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SHALL BE
ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL
DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.
E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING
ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR
SHALL COORDINATE DOWN-TIME WITH THE OWNER.
F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION,
DETAILS, ETC.
G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW
WORK.
H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEND AS
NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM
EQUIPMENT TO REMAIN.
I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-
INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION
OF EXISTING CIRCUITS OR WIRING.
J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANICAL
EQUIPMENT TO BE REMOVED OR RELOCATED.
K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN
ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.
L. CONTRACTOR TO PROVIDE MINIMUM WORKING CLEARANCES AS
PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR
CABINETS.
M. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE
COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITION AND
COMPLIES WITH SPECIFICATIONS.
N. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING
ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW
TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.
O. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN
FINISHED AREAS.
GENERAL NOTES:
KEY NOTES:#
1 ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT AND ETC WITHIN
EXISTING BUILDING IS TO BE REMOVED TO ACCOMMODATE
REMODEL, UNLESS SPECIFICALLY INDICATED OTHERWISE. REMOVE
ALL ASSOCIATED CONDUIT AND CONDUCTORS.
2 EXISTING ELECTRICAL DEVICES AND ETC WITHIN THIS AREA IS TO BE
REMOVED OR RELOCATED AS REQUIRED TO ACCOMMODATE
REMODEL, UNLESS SPECIFICALLY INDICATED OTHERWISE. REMOVE
ALL ASSOCIATED CONDUIT AND CONDUCTORS BACK TO SOURCE
WHEN NOT BEING REUSED. ELECTRICAL CONTRACTOR SHALL
MAINTAIN/RE-ESTABLISH CONTINUITY TO ALL DOWNSTREAM
EQUIPMENT/DEVICES THAT ARE TO REMAIN.
3 E.C. SHALL REMOVE EXISTING UNUSED PANEL AND ALL ASSOCIATED
CONDUIT AND CONDUCTORS THAT ARE NOT USED TO PROVIDE
SPACE FOR NEW DISCONNECT SWITCH. FIELD VERIFY THAT ALL
EXISTING CIRCUITS IN PANEL ARE ABANDONED. ANY CIRCUIT STILL
IN USE SHALL BE MOVED TO PANEL 'B'.
4 EXISTING LIGHTING IN THIS ROOM TO REMAIN, LOCATE AND
PROTECT DURING CONSTRUCTION. PROVIDE NEW CIRCUITING AND
CONTROLS AS INDICATED ON DRAWINGS.
5 EXISTING ELECTRICAL DEVICE TO BE RELOCATED; REFER TO NEW
DRAWINGS FOR NEW LOCATION. EXTEND EXISTING CIRCUITING TO
NEW LOCATION.
6 POWER FOR EXISTING DENTAL AIR COMPRESSOR AND VACCUM
SHALL BE RELOCATED TO NEW MECHANICAL ROOM. E.C. SHALL
PULLBACK EXISTING CIRCUITS AND EXTEND TO NEW LOCATION.
FIELD VERIFY EXISTING ROUTING.
7 EXISTING PANEL 'C' TO BE DISCONNECTED/REMOVED AND
REPLACED WITH NEW 200A PANEL AS INDICATED. REMOVE FEEDER
BACK TO SOURCE. EXISTING BRANCH-CIRCUITS TO BE
DISCONNECTED, PULLED BACK AND THEN RE-CONNECTED TO NEW
PANEL.
8 DISCONNECT AND REMOVE EXISTING DEVICE; REMOVE ASSOCIATED
CONDUIT AND CONDUCTORS BACK TO SOURCE.
MAINTAIN/RE-ESTABLISH CONTINUITY TO ALL DOWNSTREAM
EQUIPMENT/DEVICES THAT ARE TO REMAIN.
9 EXISTING DEVICE TO REMAIN; LOCATE AND PROTECT DURING
CONSTRUCTION.
13053
ST ATE O F I D A HOSHAWNA.M E A D O R R E G I S TEREDRP
O F E S S I O N AL ENGIN
E
E
R
Engineering Inc.
Consulting Engineers1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. JOB #1998
9/29/19
1/
1
5
/
2
0
2
0
1
:
5
2
:
5
9
P
M
E0.1
EXISTING
ELECTRICAL
PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
16'8'0"SCALE: 1/8" = 1'-0"1 EXISTING ELECTRICAL PLAN
no. description date
1 PR#05 01/15/20
1
REF.
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
WD
D
S CD3
S CD3
S CD3
SPD
SCD3SCD6
S CD3
S CD3
S CD3
SP
D
WD
1
S CD6SCD6
WD
1
SCD3
SPD
S CD3
WP
1
D
D
S CD6
SCD6
S CD6
S CD6
S CD6
WD
1
WD
1
SPD
SCD2
F
F
F
1
A
B
C
2 3
D
4
5
(E) OPERATORY
A205
(E) OPERATORY
A206
(E) OPERATORY
A207
(E) OPERATORY
A208
OPERATORY
137
OPERATORY
136
(E) IT
A212
EXAM
138
(E) HALL
A215
(E) EXAM
A216
(E) XRAY
A218
ELEC
132
RESTROOM
128
(E) PROCEDURE
A225 (E) EXAM
A226
(E) EXAM
A227
(E) EXAM
A228
(E) EXAM
A229
(E) NURSE STATION
A230
(E) RECEPTION
A231
(E) PHARMACY
A232
(E) WAITING/RECEPTION
A233
(E) STORAGE
A235
(E) CORR.
A240
EXAM
139 OPERATORY
140
(E) LAB
A244
(E) RESTROOM
A247
(E) RESTROOM
A248
(E) KID ROOM
A249
CONFERENCE
119
BREAKROOM
118
RESTROOM
117
OFFICE
116
OFFICE
114
OFFICE
109
OFFICE
107
OFFICE
127
PLAY THERAPY
106
MECH/ELEC
124
OFFICE
110
OFFICE
123
OFFICE
122
OFFICE
113
OFFICE
115
OFFICE
121
OFFICE
126
STORAGE
141
MEDICAL STORAGE
133
CORR
131
LAB STORAGE
130
LAB
129
OFFICE
111
MECH
142
RECEPTION
105
(TYP)F2
(TYP)F3
F2E
F2E
(TYP)F2
(TYP)F2
F2E
F2E
(TYP)F2
F2E
(TYP)F2
(TYP)F2
(TYP)F2
F2E
(TYP)F3
(TYP)F3
(TYP)F3 (TYP)F3
(TYP)F3
(TYP)F3
F5EF5
(TYP)F3E
(TYP)F3
(TYP)F3
(TYP)F3
(TYP)F3
F2F2
F2E
F2E
(TYP)F2
(TYP)F3
(TYP)F3
F1
F1
F1
F1
F1
F1
NLF2E
TOILET
104
WAITING
102
(TYP)F3
'D'
F4
F4 F4FA1
FA1
F4
F2E
F3E
F2E
D-5
D-3
D-1
D-1
D-1
D-1
D-1
D-3
D-3
D-3
D-3
D-3
D-3
D-3
D-3D-3
D-3
D-3
D-5
D-5
D-5
D-5
D-5
D-5
D-5 D-1
D-1
D-5
D-5
D-5
D-5
D-1
D-5
D-1
D-1
D-3
F1
F5
(TYP)F4 (TYP)F4
F4 F4 F4
(TYP)F4
F4E
F4
F4
1
2
2 2
'A'
'DS-MAIN'
'B'
33
3
3
3
D-1
FA1
F4 F4
EF-1
EF-2
EF-3
4
F10
10' -0"
D-7
F10E
10' -0"
4 D-7
F10E
10' -0"
D-7
4
F10E
10' -0"
D-7
4
2
2
3
2
F4
F4 F4 F4
F4F4E
1
2
5
A. REFER TO SYMBOL SCHEDULES FOR GENERAL NOTES
ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM; LIGHTING,
POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC.
GENERAL NOTES:
KEY NOTES:#
1 NEW LOCATION OF RELOCATED DEVICE.
2 EXISTING LIGHTING IN THIS ROOM TO REMAIN, LOCATE AND
PROTECT DURING CONSTRUCTION. PROVIDE NEW CIRCUITING AND
CONTROLS AS INDICATED ON DRAWINGS.
3 CONNECT NEW LIGHTING TO EXISTING LIGHTING CIRCUIT WITHIN
AREA OF REMODEL; FIELD VERIFY HOMERUN LOCATION; PROVIDE
NEW CONTROLS AS INDICATED.
4 CIRCUIT VIA 8-RELAY LIGHTING CONTROL PANEL WITH
ASTRONOMICAL TIME CLOCK, LEVITON EZ-MAX PLUS MODEL
NO.RO8BD-### OR EQUAL. LOCATE ADJACENT TO PANEL WHERE
LIGHTING IS CIRCUITED, OR AS INDICATED OTHERWISE ON
DRAWINGS. PROVIDE RELAYS AS REQUIRED FOR CIRCUITS AND
PROGRAM PER OWNERS DIRECTION. PROVIDE ADDITIONAL
UNSWITCHED LEG AS NEEDED FOR CONNECTION TO BATTERY
PACKS OF EMERGENCY FIXTURES.
5 CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS; PROVIDE
ADDITIONAL UNSWITCHED LEG FOR CONNECTION TO EMERG.
FIXTURE BATTERY PACK. FIELD LOCATE EXISTING CIRCUIT
HOMERUN LOCATION.
13053
ST ATE O F I D A HOSHAWNA.M E A D O R R E G I S TEREDRP
O F E S S I O N AL ENGIN
E
E
R
Engineering Inc.
Consulting Engineers1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. JOB #1998
9/29/19
1/
1
5
/
2
0
2
0
1
:
5
3
:
0
4
P
M
E1.0
LIGHTING PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
SCALE: 1/8" = 1'-0"1 LIGHTING PLAN
16'8'0"
no. description date
1 PR#05 01/15/20
1
REF.
F
JJ
J
TV
AV
TV
J
J
F
F
1
A
B
C
2 3
D
4 5
(E) OPERATORY
A205
(E) OPERATORY
A206
(E) OPERATORY
A207
(E) OPERATORY
A208
OPERATORY
137
OPERATORY
136
(E) IT
A212
EXAM
138
(E) HALL
A215
(E) EXAM
A216
(E) XRAY
A218
ELEC
132
RESTROOM
128
(E) PROCEDURE
A225 (E) EXAM
A226
(E) EXAM
A227
(E) EXAM
A228
(E) EXAM
A229
(E) NURSE STATION
A230
(E) RECEPTION
A231
(E) PHARMACY
A232
(E) WAITING/RECEPTION
A233
(E) STORAGE
A235
(E) HALL
A236
(E) CORR.
A240
EXAM
139
OPERATORY
140
(E) LAB
A244
(E) RESTROOM
A247
(E) RESTROOM
A248
(E) KID ROOM
A249
CONFERENCE
119BREAKROOM
118
RESTROOM
117
OFFICE
116
OFFICE
114
OFFICE
109
OFFICE
107
OFFICE
127
PLAY THERAPY
106
MECH/ELEC
124
RESTROOM
108
OFFICE
110
OFFICE
123
OFFICE
122OFFICE
113
OFFICE
115
OFFICE
121
OFFICE
126
STORAGE
141
CORR
131
LAB STORAGE
130
LAB
129
CORR
135OFFICE
111
MECH
142
RECEPTION
105
AC AC
AC
AC
AC
AC
42"
TR
TRTR
TR
TR
TR
42"
WAITING
102
TOILET
104
CORR.
112
CORR.
120
CORR.
125
EWC
42"
'A'
'DS-MAIN'
'B'
'D'
'DS-D'
D-2
D-2
D-2
D-2
D-2
D-2
D-4
D-4
D-4
D-4
D-4
D-4
D-6
D-6
D-6
D-6 D-6
D-8
D-8
D-8
D-8
D-8
D-8
D-10
D-10
D-10
D-10
D-10
D-12D-12
D-12
D-12
D-12
D-12
D-10
D-14D-14
D-14
D-14
D-14D-14
1
D-16
D-16
D-16
D-16
D-16
1
D-18
D-18
D-18 D-18
D-20
D-20
2
D-35,37
#8'SD-11
D-11
D-11
D-11
D-11
D-11
D-13
D-13
D-13
D-13
D-13
D-17
D-17
D-17
D-17
D-17
D-15
D-15
D-15 D-15
D-15
D-15
D-19
D-19
D-19
D-19
D-21 D-21
D-21
D-21
D-21
D-23
D-23
D-23
D-23
D-22
D-22
D-22
D-22
D-22
D-24
D-24
D-24 D-24
3
AIR
COMP.
DENTAL
VAC.
4
ACAC
ACAC
AC
AC
AC
ACACACAC
ACAC
5
6
7
5
6
7
7
7 5
6
7
B-23
B-30
B-26B-22
B-24
B-24
B-24
B-24
8
8
8
8
B-28
B-28
B-28
B-28
B-32
B-32
B-32
B-32
B-32
B-32
B-34
B-34
B-34
B-34 B-34
B-34
9
D-16
D-6
D-14
10
D-16
11
(ON ROOF)
RT-3
(ON ROOF)
RT-2
(ON ROOF)
RT-1
12
12
D-25
13 D-27
DW R
D-26
EF-4
WP
14
WP
14
WP 14
D-4
D-13
D-10
WH-1
D-31,33
#10's
'C'
D-24D-24
15
15
RECIRC.
PUMP
CONNECT TO
EXISTING RECPT.
CIRCUIT
B-37
16
17
17
1
15
A. REFER TO SYMBOL SCHEDULES FOR GENERAL NOTES
ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM; LIGHTING,
POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC.
GENERAL NOTES:
KEY NOTES:#
1 PROVIDE AND INSTALL 2-GANG, CONCRETE FLOORBOX. PROVIDE
WITH DUPLEX RECEPTACLE AND DATA CONDUIT AS INDICATED ON
DRAWINGS. FLOORBOX SHALL BE HUBBELL SYSTEMONE SERIES:
CFB2G30CR, PROVIDE REQUIRED COVERPLATE TO MATCH NEW
FLOORING SYSTEM. E.C. SHALL SAW CUT AND PATCH EXISTING
FLOOR AS REQUIRED FOR INSTALLATION OF FLOORBOX;
COORINATE WITH G.C.
2 CONNECTION TO RANGE HOOD, COORDINATE CONNECTION WITH
EQUIPMENT PRIOR TO ROUGH-IN.
3 INSTALL 1 1/4" CONDUIT FROM FLOORBOX TO ABOVE ACCESSIBLE
CEILING FOR ROUTING LOW VOLTAGE CABLING.
4 POWER FOR EXISTING DENTAL AIR COMPRESSOR AND VACCUM
SHALL BE RELOCATED TO NEW MECHANICAL ROOM. E.C. SHALL
PULLBACK EXISTING CIRCUITS AND EXTEND TO NEW LOCATION.
FIELD VERIFY EXISTING ROUTING.
5 POWER AND TV OUTLET IN CEILING FOR TV; FIELD VERIFY LOCATION
WITH OWNER PRIOR TO ROUGH-IN.
6 POWER IN FLOOR FOR DENTAL CHAIR; FIELD VERIFY CONNECTION
REQUIREMENTS WITH EQUIPMENT, SAWCUT AND PATCH EXISTING
FLOOR AS REQUIRE TO INSTALL POWER TO CHAIR.
7 ALL 120V CIRCUITING FOR RECEPTACLES WITHIN EXAM OR
OPERATORY ROOMS SHALL BE PROVIDED WITH A REDUNDANT
GROUND OR MEDICAL GRADE MC CABLE. WIRING METHODS SHALL
CONFORM TO NEC ARTICLE 517.
8 CONNECT TO EXISTING RECEPTACLE CIRCUIT WITHIN AREA; FIELD
VERIFY.
9 (3) 2" CONDUIT SLEEVES FOR ROUTING OF LOW VOLTAGE
CABLING(BY OWNER). STUB CONDUITS FROM IT ROOM TO ABOVE
ACCESSIBLE CEILING IN HALLWAY OF NEW BUILDING. COORDINATE
WITH OWNER.
10 POWER FOR MOTORIZED SCREEN; COORDINATE LOCATION AND
CONNECTIONS WITH EQUIPMENT.
11 RECEPTACLE MOUNTED FLUSH IN CEILING FOR OVERHEAD
PROJECTOR, VERIFY EXACT LOCATION WITH OWNER PRIOR TO
ROUGH-IN. INSTALL J-BOX ABOVE CEILING MOUNTED TO STRUCTURE
WITH A 10FT MC CABLE WHIP TO RECEPTACLE.
12 CONNECTION TO AUTOMATIC ADA DOORS; FIELD VERIFY
CONNECTION LOCATION AND REQUIREMENTS WITH EQUIPMENT
INSTALLERS. PROVIDE ALL REQUIRED ROUGH-IN AND
CONNECTIONS TO PUSH-BUTTONS.
13 PROVIDE ELECTRICAL CONNECTION TO BUILDING MOUNTED
SIGNAGE; FIELD VERIFY EXACT ROUGH-IN AND CONNECTION
LOCATION WITH SIGN INSTALLER. ROUTE CIRCUIT THROUGH
LIGHTING CONTROL PANEL AND PROGRAM PER OWNER DIRECTION.
14 RECEPTACLE MOUNTED TO HVAC UNIT, COORDINATE MOUNTING
WITH M.C. PRIOR TO ROUGH-IN.
15 EXISTING DEVICE TO REMAIN; LOCATE AND PROTECT DURING
CONSTRUCTION.
16 PROVIDE NEW 20A/1P BREAKER IN EXISTING PANEL.
17 DEVICES MOUNTED IN MILLWORK, E.C SHALL COORINATE EXACT
PLACEMENT WITH MILLWORK INSTALLER PRIOR TO ROUGH-IN. STUB
RACEWAY FROM EACH TELE/DATA OUTLET TO NEAREST
ACCESSIBLE CEILING, PROVIDE PULL STRING.
13053
ST ATE O F I D A HOSHAWNA.M E A D O R R E G I S TEREDRP
O F E S S I O N AL ENGIN
E
E
R
Engineering Inc.
Consulting Engineers1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. JOB #1998
9/29/19
1/
1
5
/
2
0
2
0
1
:
5
3
:
0
5
P
M
E2.0
POWER/DATA
PLAN
1906
09/26/2019
G
R
A
N
D
P
E
A
K
S
R
E
N
O
V
A
T
I
O
N
R
E
X
B
U
R
G
,
I
D
A
H
O
SCALE: 1/8" = 1'-0"1 POWER/DATA PLAN
16'8'0"
MECHANICAL - ROOFTOP UNIT SCHEDULE
ID #VOLTS PH.MCA PANEL CIRCUIT FEEDER
DISCONNECT
SIZE
DISCONNECT
TYPE NOTES
RT 1 240 V 3 25 A C 8,10,12 3/4"C.,3#8+1#10G 60 A FUSED/NEMA 3R 2
RT 2 240 V 3 28 A C 13,15,17 3/4"C.,3#8+1#10G 60 A FUSED/NEMA 3R 2
RT 3 240 V 3 25 A C 14,16,18 3/4"C.,3#8+1#10G 60 A FUSED/NEMA 3R 2
1. ROUTE FAN CIRCUIT THROUGH 2ND RELAY OF ROOM LIGHTING OCCUPANCY SENSOR AND SET DELAY TO 30 MIN.
2. E.C. SHALL PROVIDE LOCAL DISCONNECT SWITCH FOR EQUIPMENT; SIZE AND TYPE AS INDICATED IN SCHEDULE. IF FUSED
DISCONNECT IS SPECIFIED FOR EQUIPMENT, FUSE PER EQUIPMENT NAMEPLATE RATING.
3. E.C. SHALL PROVIDE LOCAL DISCONNECT RATED, THERMAL-OVERLOAD SWITCH FOR EQUIPMENT; SWITCH RATING SHALL NOT BE
LESS THEN CIRCUIT BREAKER SUPPLYING EQUIPMENT.
4. EQUIPMENT IS FACTORY SUPPLYED WITH DISCONNECT AND CONVIENENCE OUTLET; E.C. SHALL PROVIDE ALL NECESSARY
CONNECTIONS.
MECHANICAL SCHEDULE NOTES:
MECHANICAL - EXHAUST FAN SCHEDULE
ID #VOLTS PH.WATTS PANEL CIRCUIT FEEDER CONTROL NOTES
EF 1 120 V 1 87 W D 5 1/2"C.,2#12+1#12G W/LIGHTS
EF 2 120 V 1 87 W D 1 1/2"C.,2#12+1#12G W/LIGHTS
EF 3 120 V 1 87 W D 5 1/2"C.,2#12+1#12G W/LIGHTS
EF 4 120 V 1 100 W D 18 1/2"C.,2#12+1#12G TIMER SWITCH
no. description date
1 PR#05 01/15/20
1