HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00444 - 55 E 1st N - RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/10/2020 1:24 pm Permit Details Permit Number: 11-00444 55 E 1st N - Remodel 55 E 1st N New Single Family Residence Permit Issued Date: 05/05/2014 Permit Inspection Statistics 15Total Inspections Completed: 8Total Inspections Passed: Inspection Pass Rate: 53.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/21/2012PassQuinton OwensFraming/Structure Inspection Already started work before brought to bldg. dept's attention. Need header above bathroom door on east unit. Mostly non-bearing partitions. Need to obtain bldg permit due to occupancy change and CUP for duplex in LDR2 zone. Header at bathroom approved 2/21, QO Inspector Comments: 02/21/2012FailQuinton OwensSheetrock/Drywall Inspection Bathroom partywall approved. closet in living room missing 5/8" drywall. 1/2" drywall on some ceilings other areas have plaster. Add 5/8" to 1/2". Need to obtain rating on plaster. Inspector Comments: 02/22/2012N/AQuinton OwensSheetrock/Drywall Inspection Fire occurred in basement of home. Will wait to hear from owner on plans for building. Inspector Comments: 11/28/2012FailQuinton OwensSheetrock/Drywall Inspection 5/8" drywall required at party wall in closet around elec. panel. Bathroom party wall not yet drywalled. Inspector Comments: 06/14/2013FailQuinton OwensBuilding Final Address #'s to be contrasting colors with wall (both). CO detector outside bedrooms (both units). Metal plate cover over clean out on party wall (west unit). Fire separation in crawl space/basement. Finish nailing holes in joist hangers. CUP required for duplex (no dormitory housing allowed & driveway paved). Heat supply in west unit bathroom? Inspector Comments: 09/22/2014PassQuinton OwensCommercial Sheetrock/Drywall Inspection 09/22/2014PassQuinton OwensCommercial Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 11-00444 55 E 1st N - Remodel 55 E 1st N New Single Family Residence Permit Status of (Open) as of Report Date: 03/10/2020 1:24 pm Permit Inspection Summary Electrical Inspection Type 11/16/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the front room of the east unit where the fire was, wires were burned and replaced for new. Inspector Comments: 04/10/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Dishwashers need breaker locks-hard wired, GFCI protection required in kitchens for counter top receptacles, GFCI protection required for all bathroom receptacles, tamper resistant receptacles required throughout both units entirely, AFCI protection required in all bedrooms circuits, junction box cover needed in the crawl space, switch and connector needed for the furnace in the crawl space, 8/3 wire in the crawl space needs to be terminated, open ground in the bath GFCI's in both units, blanks needed in the panel in the front unit, breaker locks needed for the water heaters in both units, disposal in front unit hard wired and cord is cut off-not listed and no disconnect for unit, call for a re-inspect when ready. Inspector Comments: 09/03/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-both units, items from previous inspection done, water heaters were existing. Inspector Comments: Mechanical Inspection Type 04/10/2013FailQuinton OwensHVAC Final Inspection No Condensate drainage. Support furnace exhaust. No supply vent allowed to west uinit (East side only). Inspector Comments: 09/22/2014PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 02/09/2012PassDon AllenPlumbing Rough-in all good to coverInspector Comments: 05/28/2013FailDon AllenPlumbing Final Inspection 4/10/13 DA: Disposal kit need for kit. sink. Need auto vent in 2 bath sink. Need auto vent in kitchen need to put t&p drops in water heater. Inspector Comments: 09/22/2014PassDon AllenPlumbing Final Inspection Page 2 of 2