HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00546 - 51 S 1st E - Legacy AptsPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Issued Date: 08/18/2014 Permit Inspection Statistics 25Total Inspections Completed: 21Total Inspections Passed: Inspection Pass Rate: 84.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 12/04/2012PassQuinton OwensResidential Footing Inspection Existing buildingInspector Comments: 12/04/2012PassQuinton OwensFoundation Inspection Existing buildingInspector Comments: 04/01/2013PassQuinton OwensResidential Framing/Structure Inspection 1/29: North side of West end- Fix Ceiling Insulation falling out. Bath exhaust fans need correction. 1/31: North side of west end ok for drywall. 2-05: Ceiling Framing and solid metal ducts ok to cover. 2-07: Framing in East wing 2nd floor ok to cover. 2-15: Fireblocking in 2 west units on 1st floor with firecaulking on interior wall and at Tub wall ok. 3/4: 2 units on North side of East wing- notched top chord of TJI. Large open gaps between top plates and drywall at rated ceiling.Firecaulk appropriate penetrations. (Fixed 3/6). 3/13: South wing hallway & fire partitions ok to cover 1 side for insulation. 3/22: South wing main floor- 3 units have holes in bearing wall that are too large. 2 notched joists.(3/25: fixed 1 secured to intersecting wall for support and headers attached at other locations) 4/1: South wing Bottom floor -ceiling not rated above Ducts in dropped ceiling NW unit -Reinspect required before covering (fixed and inspected 4/4) Inspector Comments: 04/01/2013PassQuinton OwensResidential Insulation Inspection 3/22/13 - 3 units have holes in bearing wall too large. 2 notched joists. (1 supported by stud with intersecting wall. 2 had headers put in to support joist. Joists with notches added plywood to side) 3/26/13 - 1st level on south wing - Insulation ok. Missing fire separation in NW unit above ducts in bdrm and dropped ceiling behind closet (inspection needed). Inspections done typically with framing reinspects. (Exterior building shell existing) Inspector Comments: Page 1 of 6 (Continued) Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Inspection Summary 04/04/2013FailQuinton OwensResidential Building Final North wing- Rating protection at cleanouts on party walls. Rm 106 - west bdrm smk det. not interconnected. Grab bars in accessible bathroom. Dryer vent in 111 missing. Rm 108- Smk det not interconnected (east bdrm). Firecaulk penetrations above mech units in apartments. Stairs to roof: lights not working and firecaulk sprinkler. Rm 209 Bath Fan on north side not working. Rm 211 - Fire sprinkler patch needed. Rm 205 - Lights & fans in bthrm not working. Exit sign needed at bottom of stairs. Building address numbers. Inspector Comments: 04/11/2013PassQuinton OwensSidewalk Inspection ExistingInspector Comments: 05/09/2013FailQuinton OwensResidential Building Final South Wing - 5/8" drywall in storage room on corridor wall. Smk Det interconnection error in 212. Firecaulk under lav's in 215 and 112. Handrail at stairs & return to wall. Maintain rating at attic access in hall. Need medal cleanout cover under lav. in 112. Smk det not installed (116). Fix grab bars in 116. Inspector Comments: 05/20/2013PassQuinton OwensResidential Building Final 4/11/13: North portion building final approved. 5/20/13: South portion approved (south exterior window replaced with 5/8" type x exterior drywall for 1 hour rating - rest of wall CMU). Inspector Comments: 06/14/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection 2-07: ceiling drywall double layer approved. 2-09: East wing 2nd floor OK to cover except south side unit which needs firecaulking around duct penetration in ceiling. 2/19: 2 units in west wing on 1st floor. Flex duct penetrating above rated ceiling disapproved. Firecaulk penetrations in rated ceiling. Add screws at back closet corner and by window in corner of West unit, west bdrm. 2/27: 2 west units of east wing 1st floor. Drywall inspection approved and previous unit items OK. 3/11: Last units on north side of east wing. OK 3/13: Entry area and south unit on East wing. 3/15: South wing Upper floor- East units OK. South unit needs 5/8" on wall common with corridor. West side not ready. 3/20: Upper flr south unit done (5/8" added to wall against corridor). West side units approved. 4/1: OK bottom floor east and south end. NW unit needs fire rating above ductwork (flex ducts) in closet and above door to bedroom. 4/3: Covered areas in NW unit of south wing were to be reinspected. (done 4-4). Missed screws in NE unit on wall facing bathroom sinks (done 4-4). Inspector Comments: Page 2 of 6 (Continued) Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Inspection Summary Electrical Inspection Type 03/12/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 1/25/13 - Approved for cover in the west units upstairs from the middle stairway to the west end only, not including the corridor. 1/30/13 - SE unit needs receptacle just inside door on wall between door and closet-contractor made corrections while on site, Approved for cover-last six units on the second floor-as per Jane Shaw. 2/11/13 - Approved for cover in the bottom level west two units only. 2/15/13 - Approved for cover in the 4 north east units on the bottom level only-inspected the fire alarm wiring in these units also. 2/19/13 - Approved for cover in the hallways on the first and second floors and the laundry room on the second floor-first floor is not done on the middle portion of the building, the second floor is done from the east to the west entirely. This does not include the south portion of the building. 3/8/13 - Approved for cover in the main lobby area only-not ready for a final in the upstairs units. 3/13/13 - Approved for cover in the south units of the complex. Also inspected the north units on the second floor for a final-southeast unit AFCI tripping for the bedroom and kitchen cabinet does not have a receptacle for it (wider than 12"), unit by stairs range receptacle not installed and KO seal missing, bath receptacle reverse polarity and kitchen missing receptacle for counter top in south unit, breaker blanks needed in a few units (3), receptacles in west unit on south wall labeled for source, call for a re-inspect when ready. Inspector Comments: Page 3 of 6 (Continued) Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Inspection Summary 05/10/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 3/13/13 - Approved for a final and C.O. in the two west units downstairs in the north portion of the building and the entire upstairs units in the north portion of the building as well, no hallways or corridors are included in this. Items were corrected from prior inspection. 3/28/13 - Approved for a final and C.O. in the two west units downstairs in the north portion of the building and the entire upstairs units in the north portion of the building as well, no hallways or corridors are included in this. Items were corrected from prior inspection. 4/4/13 - Electrician on site to install breaker lockouts on water heater-as per Jane Shaw-north portion of building only. 5/10/13 - Approved for a final and C.O.-last 10 units in the south portion-breaker lock for heater in storage room, breaker blank needed in the south unit on the 2nd level-will re-inspect these items on the fire alarm final inspection. Inspector Comments: Page 4 of 6 (Continued) Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Inspection Summary Fire Inspection Type 02/06/2013PassDale PickeringFire Sprinkler Rough-in 1/24/13 - Approved for cover on west end of 2nd floor 1/31/13 - East end of 2nd floor and west end of 1st floor approved for cover. 2/6/13 - 1st floor east end OK to cover. 3/18 All of the north building is approved for cover. DP Inspector Comments: 03/18/2013PassDale PickeringFire Underground Inspection Flush - OKInspector Comments: 03/18/2013PassDale PickeringFire Sprinkler Hydro 3/18 Underground hydro (200# / 2 hours) and flush is approved. DPInspector Comments: 04/08/2013FailBret StoddardFire Alarm Final Inspection Weight room, units 107, 108, 109, and upstairs hallway have horn strobes that are either not working or not installed, call for a re-inspect when ready. Inspector Comments: 05/17/2013PassBret StoddardFire Alarm Final Inspection 4/11/13 - Approved for a final-fire alarm-north wing only. 4/12/13 - Witnessed flow switch operation for notification-40 seconds until fire alarm system operated. 5/17/13 - Approved for a final and C.O. in the south portion-this completes the entire building for a fire alarm final-witnessed 24 hour 5 minute test, inspection ticket is stapled to the fire alarm contractors test report. Inspector Comments: 05/20/2013PassDale PickeringFire Sprinkler Final Inspection Thrust Block: Pass 3/5/13 5/20/13 - 113 Sprinkler trim. 215 FE and two others west interior needs repair. 201 FE in west end. Will reinspect in 1 week. *signed off with CO Inspector Comments: Page 5 of 6 (Continued) Permit Details Permit Number: 12-00546 51 S 1st E - Legacy Apts 51 S 1st E New Multi-Family Residence Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am Permit Inspection Summary Mechanical Inspection Type 04/01/2013PassQuinton OwensHVAC Rough-in 1-31: 4 units on North side of West end. Exhaust fan and ducting all metal - OK to cover with Fire rated ceiling. Fans exhausts from each units connected, but separated per unit as required and approved. Remaining mechanical placed below rated ceiling. 2/05: East wing 2nd floor ok. 2/13: West wing 1st floor ok. East and South wing rough in was inspected and approved with framing inspections. Inspector Comments: 04/04/2013FailQuinton OwensHVAC Final Inspection Boiler room: Furnace needs comb. air. (boiler tied to damper electrically to operate when needed. Other furnace will also need comb air when damper is closed (may be run as direct vent). Inspector Comments: 05/09/2013PassQuinton OwensHVAC Final Inspection 4/11/13, QO: North end - Mechanical room at west end and furnace units under stairs. Penetrations rated and ductwork penetrations are metal all the way to equipment. Final approved. 5/9/13,QO: South wing approved. Inspector Comments: Plumbing Inspection Type 01/04/2013PassDon AllenPlumbing Underground Inspection 12/14/12 - All good to cover 1st 3 on the east side. 12/21/12 - Partial underground - *approved 1/2/13 - All good to cover underground. Inspector Comments: 02/08/2013PassDon AllenPlumbing Sewer 11/30/12 - Sewer Main - All good to cover.Inspector Comments: 02/08/2013PassDon AllenPlumbing Rough-in all is good to cover still need to see test 2/4/13 - All good to cover. 3/22/13 - Wall - All good to cover Roughin. Inspector Comments: 05/16/2013PassDon AllenPlumbing Water 05/16/2013PassDon AllenPlumbing Final Inspection All good for the C/OInspector Comments: Page 6 of 6