Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Issued Date: 08/18/2014
Permit Inspection Statistics
25Total Inspections Completed:
21Total Inspections Passed:
Inspection Pass Rate: 84.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
12/04/2012PassQuinton OwensResidential Footing Inspection
Existing buildingInspector Comments:
12/04/2012PassQuinton OwensFoundation Inspection
Existing buildingInspector Comments:
04/01/2013PassQuinton OwensResidential Framing/Structure Inspection
1/29: North side of West end- Fix Ceiling Insulation falling out. Bath exhaust fans
need correction.
1/31: North side of west end ok for drywall.
2-05: Ceiling Framing and solid metal ducts ok to cover.
2-07: Framing in East wing 2nd floor ok to cover.
2-15: Fireblocking in 2 west units on 1st floor with firecaulking on interior wall
and at Tub wall ok.
3/4: 2 units on North side of East wing- notched top chord of TJI. Large open
gaps between top plates and drywall at rated ceiling.Firecaulk appropriate
penetrations. (Fixed 3/6).
3/13: South wing hallway & fire partitions ok to cover 1 side for insulation.
3/22: South wing main floor- 3 units have holes in bearing wall that are too large.
2 notched joists.(3/25: fixed 1 secured to intersecting wall for support and
headers attached at other locations)
4/1: South wing Bottom floor -ceiling not rated above Ducts in dropped ceiling
NW unit -Reinspect required before covering (fixed and inspected 4/4)
Inspector Comments:
04/01/2013PassQuinton OwensResidential Insulation Inspection
3/22/13 - 3 units have holes in bearing wall too large. 2 notched joists. (1
supported by stud with intersecting wall. 2 had headers put in to support joist.
Joists with notches added plywood to side)
3/26/13 - 1st level on south wing - Insulation ok. Missing fire separation in NW
unit above ducts in bdrm and dropped ceiling behind closet (inspection needed).
Inspections done typically with framing reinspects. (Exterior building shell
existing)
Inspector Comments:
Page 1 of 6
(Continued)
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit
Inspection
Summary
04/04/2013FailQuinton OwensResidential Building Final
North wing- Rating protection at cleanouts on party walls. Rm 106 - west bdrm
smk det. not interconnected. Grab bars in accessible bathroom. Dryer vent in 111
missing. Rm 108- Smk det not interconnected (east bdrm). Firecaulk penetrations
above mech units in apartments. Stairs to roof: lights not working and firecaulk
sprinkler. Rm 209 Bath Fan on north side not working. Rm 211 - Fire sprinkler
patch needed. Rm 205 - Lights & fans in bthrm not working. Exit sign needed at
bottom of stairs. Building address numbers.
Inspector Comments:
04/11/2013PassQuinton OwensSidewalk Inspection
ExistingInspector Comments:
05/09/2013FailQuinton OwensResidential Building Final
South Wing - 5/8" drywall in storage room on corridor wall. Smk Det
interconnection error in 212. Firecaulk under lav's in 215 and 112. Handrail at
stairs & return to wall. Maintain rating at attic access in hall. Need medal
cleanout cover under lav. in 112. Smk det not installed (116). Fix grab bars in
116.
Inspector Comments:
05/20/2013PassQuinton OwensResidential Building Final
4/11/13: North portion building final approved.
5/20/13: South portion approved (south exterior window replaced with 5/8" type
x exterior drywall for 1 hour rating - rest of wall CMU).
Inspector Comments:
06/14/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection
2-07: ceiling drywall double layer approved.
2-09: East wing 2nd floor OK to cover except south side unit which needs
firecaulking around duct penetration in ceiling.
2/19: 2 units in west wing on 1st floor. Flex duct penetrating above rated ceiling
disapproved. Firecaulk penetrations in rated ceiling. Add screws at back closet
corner and by window in corner of West unit, west bdrm.
2/27: 2 west units of east wing 1st floor. Drywall inspection approved and
previous unit items OK.
3/11: Last units on north side of east wing. OK
3/13: Entry area and south unit on East wing.
3/15: South wing Upper floor- East units OK. South unit needs 5/8" on wall
common with corridor. West side not ready.
3/20: Upper flr south unit done (5/8" added to wall against corridor). West side
units approved.
4/1: OK bottom floor east and south end. NW unit needs fire rating above
ductwork (flex ducts) in closet and above door to bedroom.
4/3: Covered areas in NW unit of south wing were to be reinspected. (done 4-4).
Missed screws in NE unit on wall facing bathroom sinks (done 4-4).
Inspector Comments:
Page 2 of 6
(Continued)
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit
Inspection
Summary
Electrical Inspection Type
03/12/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
1/25/13 - Approved for cover in the west units upstairs from the middle stairway
to the west end only, not including the corridor.
1/30/13 - SE unit needs receptacle just inside door on wall between door and
closet-contractor made corrections while on site, Approved for cover-last six units
on the second floor-as per Jane Shaw.
2/11/13 - Approved for cover in the bottom level west two units only.
2/15/13 - Approved for cover in the 4 north east units on the bottom level
only-inspected the fire alarm wiring in these units also.
2/19/13 - Approved for cover in the hallways on the first and second floors and
the laundry room on the second floor-first floor is not done on the middle portion
of the building, the second floor is done from the east to the west entirely. This
does not include the south portion of the building.
3/8/13 - Approved for cover in the main lobby area only-not ready for a final in
the upstairs units.
3/13/13 - Approved for cover in the south units of the complex. Also inspected
the north units on the second floor for a final-southeast unit AFCI tripping for the
bedroom and kitchen cabinet does not have a receptacle for it (wider than 12"),
unit by stairs range receptacle not installed and KO seal missing, bath receptacle
reverse polarity and kitchen missing receptacle for counter top in south unit,
breaker blanks needed in a few units (3), receptacles in west unit on south wall
labeled for source, call for a re-inspect when ready.
Inspector Comments:
Page 3 of 6
(Continued)
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit
Inspection
Summary
05/10/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
3/13/13 - Approved for a final and C.O. in the two west units downstairs in the
north portion of the building and the entire upstairs units in the north portion of
the building as well, no hallways or corridors are included in this. Items were
corrected from prior inspection.
3/28/13 - Approved for a final and C.O. in the two west units downstairs in the
north portion of the building and the entire upstairs units in the north portion of
the building as well, no hallways or corridors are included in this. Items were
corrected from prior inspection.
4/4/13 - Electrician on site to install breaker lockouts on water heater-as per Jane
Shaw-north portion of building only.
5/10/13 - Approved for a final and C.O.-last 10 units in the south portion-breaker
lock for heater in storage room, breaker blank needed in the south unit on the
2nd level-will re-inspect these items on the fire alarm final inspection.
Inspector Comments:
Page 4 of 6
(Continued)
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit
Inspection
Summary
Fire Inspection Type
02/06/2013PassDale PickeringFire Sprinkler Rough-in
1/24/13 - Approved for cover on west end of 2nd floor
1/31/13 - East end of 2nd floor and west end of 1st floor approved for cover.
2/6/13 - 1st floor east end OK to cover.
3/18 All of the north building is approved for cover. DP
Inspector Comments:
03/18/2013PassDale PickeringFire Underground Inspection
Flush - OKInspector Comments:
03/18/2013PassDale PickeringFire Sprinkler Hydro
3/18 Underground hydro (200# / 2 hours) and flush is approved. DPInspector Comments:
04/08/2013FailBret StoddardFire Alarm Final Inspection
Weight room, units 107, 108, 109, and upstairs hallway have horn strobes that
are either not working or not installed, call for a re-inspect when ready.
Inspector Comments:
05/17/2013PassBret StoddardFire Alarm Final Inspection
4/11/13 - Approved for a final-fire alarm-north wing only.
4/12/13 - Witnessed flow switch operation for notification-40 seconds until fire
alarm system operated.
5/17/13 - Approved for a final and C.O. in the south portion-this completes the
entire building for a fire alarm final-witnessed 24 hour 5 minute test, inspection
ticket is stapled to the fire alarm contractors test report.
Inspector Comments:
05/20/2013PassDale PickeringFire Sprinkler Final Inspection
Thrust Block: Pass 3/5/13
5/20/13 - 113 Sprinkler trim. 215 FE and two others
west interior needs repair.
201 FE in west end.
Will reinspect in 1 week. *signed off with CO
Inspector Comments:
Page 5 of 6
(Continued)
Permit Details Permit Number: 12-00546
51 S 1st E - Legacy Apts
51 S 1st E
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 03/04/2020 10:50 am
Permit
Inspection
Summary
Mechanical Inspection Type
04/01/2013PassQuinton OwensHVAC Rough-in
1-31: 4 units on North side of West end. Exhaust fan and ducting all metal - OK
to cover with Fire rated ceiling. Fans exhausts from each units connected, but
separated per unit as required and approved. Remaining mechanical placed
below rated ceiling.
2/05: East wing 2nd floor ok.
2/13: West wing 1st floor ok.
East and South wing rough in was inspected and approved with framing
inspections.
Inspector Comments:
04/04/2013FailQuinton OwensHVAC Final Inspection
Boiler room: Furnace needs comb. air. (boiler tied to damper electrically to
operate when needed. Other furnace will also need comb air when damper is
closed (may be run as direct vent).
Inspector Comments:
05/09/2013PassQuinton OwensHVAC Final Inspection
4/11/13, QO: North end - Mechanical room at west end and furnace units under
stairs. Penetrations rated and ductwork penetrations are metal all the way to
equipment. Final approved.
5/9/13,QO: South wing approved.
Inspector Comments:
Plumbing Inspection Type
01/04/2013PassDon AllenPlumbing Underground Inspection
12/14/12 - All good to cover 1st 3 on the east side.
12/21/12 - Partial underground - *approved
1/2/13 - All good to cover underground.
Inspector Comments:
02/08/2013PassDon AllenPlumbing Sewer
11/30/12 - Sewer Main - All good to cover.Inspector Comments:
02/08/2013PassDon AllenPlumbing Rough-in
all is good to cover still need to see test
2/4/13 - All good to cover.
3/22/13 - Wall - All good to cover Roughin.
Inspector Comments:
05/16/2013PassDon AllenPlumbing Water
05/16/2013PassDon AllenPlumbing Final Inspection
All good for the C/OInspector Comments: