HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00542 - 410 W 1st N - Carriage Cove Short Stay RehabilitationPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Issued Date: 02/10/2014 Permit Inspection Statistics 60Total Inspections Completed: 51Total Inspections Passed: Inspection Pass Rate: 85.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 05/02/2013PassDale PickeringFire Underground Inspection 0935 200psi 1135 200psi Ok to cover Inspector Comments: 05/22/2014PassJoel GrayPublic Works Final Inspection OKInspector Comments: 02/13/2015PassNatalie PowellPlanning and Zoning Final Inspection Building Inspection Type 06/07/2013PassQuinton OwensFooting Inspection 5/2,QO: SE corner around North side to West courtyard. All #5 (2 cont. and across at 12" oc) 5/6,QO: South ftg reinforced as per plans. 5/8,QO: SE (final exterior section) reinforced per plans. 5/21,QO Interior courtyard reinforced per plans 5/31,QO: Interior footings 5/22,QO: Stair ftg done as per plans. 5/31,QO: West end interior ftgs and spot footings reinforced per plans. 6/6,QO: Some interior spot footings and int. wall footings at admin offices and by NE corner of courtyard. 6/7,QO: Several Spot footings done most 5 #5 rebar each way. Inspector Comments: 09/24/2013PassQuinton OwensFoundation Inspection 5/3,QO: #5 rebar at 12" oc ea way w/ 2 in top and bottom 5/6, QO: NW section Reinforced per plans 5/7,QO: Partial Fnd. ok to pour. 5/8,QO: SE (final exterior) section reinforced per plans. 5/22,QO: Interior courtyard and stair foundation rebar as per plans 6/7,QO: Interior Foundation walls by admin. offices and off NE corner of courtyard. 6/27,QO: Concrete - slab only (int ftgs dome) *did not inspect* AP 9/24,QO: Replaced conc.entry across street (needed to access underground hookups). Inspector Comments: Page 1 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary 12/18/2013Fail Insulation Inspection insulate around windows need some headers repaired. u .33 solar heat gain .25 Inspector Comments: 12/20/2013PassQuinton OwensCommercial Insulation Inspection Reinspection of steel frame headers and window perimeters.Inspector Comments: 01/16/2014FailQuinton OwensFraming/Structure Inspection fire blocking in walls over 10'. Tighten anchor bolts (various locations int. walls) Not all penetrations protected as needed. Inspector Comments: 01/23/2014PassTed DyeFraming/Structure Inspection General Progress Reinspect - Grid 1-5 fire caulks in hall complete. Bolts tightened. Inspector Comments: 01/29/2014PassQuinton OwensSheetrock/Drywall Inspection NW wing ok to tape (patient rooms done) cw8a (int walls) #5 vert 14"o.c. ea way 2 #5 top & bottom cw14a (outside N&E) #4 at 10" o.c. (each face) ea way (2) #6 top & bottom cw16a (nw corner) vert #5 at 10"o.c. vert ins face out face #4 at 10" o.c. hor #4 at 9" o.c. each face 2#6 top & bottom Inspector Comments: 02/05/2014PassQuinton OwensSheetrock/Drywall Inspection 2/5/14 - Drywall Screw - Drywall in patient rooms. East side of north wing approved for taping. Hallway grid 1-5 North Ok to hang drywall on clg's. Inspector Comments: 02/11/2014PassQuinton OwensSheetrock/Drywall Inspection Drywall West end of North wing corridor and patient rooms on East end of North wing. Approved for taping. Inspector Comments: 02/21/2014PassQuinton OwensSheetrock/Drywall Inspection North East section Drywall (mech room, laundry, custodial, etc.). Add missing screws as indicated (exterior wall by door to last room, and in custodial closet). Some penetrations in firewalls still to be firecaulked and will be inspected later. Inspector Comments: 04/14/2014FailQuinton OwensFraming/Structure Inspection Fire Barriers have several penetrations not fire rated throughout building.Inspector Comments: 04/17/2014FailQuinton OwensFraming/Structure Inspection Inspection of all Fire barriers: Fire caulked most penetrations in NE corner Fire barriers. Large vacant opening between storage and Mechanical room. Fire dampers missing on 2 ducts between 130 & 126. Fire caulk penetrations in 325, 213, 211, 116, 108, 123 (Reception), and above Fire doors by 125 and corridor C02-A. Inspector Comments: Page 2 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary 04/29/2014FailQuinton OwensBuilding Final Smoke partitions under sink penetrations to be sealed: 102, 103, 104, 106, 108, 110, 111, 113, 115, 218, 219, 222, 227,228, Under sink pipe protection missing in all patient bathrooms (except 101) Sprinkler head in "soiled linen" & Bathroom in kitchen area not trimmed out. Bathroom door in 233 catches on floor, opening width may not be enough. Dryer vents not done in Clean linen, 136. Lock control from inside walk in freezer for egress? Maxitrol R500S regulator not vented outside, not horizontal (need one or the other). 2nd fire damper between custodian room 130 & room 126 (duct through fire barrier). uncover sprinkler over stairway. Finish seal on Aluminum Grease duct cover on roof Fire caulk duct penetrations in North fire barrier wall in Attic room, A03 Duct not sealed around sensor rod through duct in Attic, A01. West wall of 108 designated as fire barrier- is window above door rated? Maximum reach height for items above bathroom counters is 44" above floor. Handicap bathroom door closer (only one installed so far) by dining closes too fast. Inspector Comments: 05/07/2014FailQuinton OwensBuilding Final Maxitrol regulators not vented outside, not horizontal (need one or the other).Behind cooking range & dryers. Finish sealing exterior grease duct cover on roof. Handicap bathroom door closer by dining closes too fast (only one of two installed so far). Inspector Comments: 05/09/2014PassQuinton OwensBuilding Final Final Building items complied with.Inspector Comments: Page 3 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary Electrical Inspection Type 01/29/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover in room units only in section A, 5 to 7 (7 units), for electrical and fire alarm wiring and conduits. Inspector Comments: 11/13/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 12/02/2013FailBret StoddardCommercial Electrical Rough-in Need to install "green" MC cable for all patient care areas as specified in the electrical plans-(lighting below 7'6"), nail plates and K.O. seals needed throughout, call for a re-inspect when ready. Inspector Comments: 12/18/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover in gridline 5 to the west in the assisted living wing for electrical and fire alarm wiring and conduit. Inspector Comments: 12/23/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover in the south side from gridline 5 to 7(assisted living portion) for electrical and fire alarm wiring/conduit. Inspector Comments: 01/08/2014PassBret StoddardCommercial Electrical Rough-in Approved for cover in the exterior walls only in the 7 north west end units.Inspector Comments: 01/16/2014PassBret StoddardCommercial Electrical Rough-in Approved for cover for electrical and fire alarm wiring in the areas from 0-5 lines on the north portion (skilled nursing wing) in all units, soffits in the 0-7 line (assist. living wing), and room 250 between the two wings hallway. Also approved for cover upstairs in the communications room-all other areas upstairs were fished in the walls after sheetrock was installed. Inspector Comments: 02/05/2014PassBret StoddardCommercial Electrical Rough-in Approved for cover in resident room #301, hair salon 126, library 124, multipurpose room 122, toilet room 120 and 118, 107, 105, 103, 102, 106, and 104 for electrical and fire alarm wiring/conduit. Inspector Comments: 02/11/2014PassBret StoddardCommercial Electrical Rough-in 02/18/2014PassBret StoddardCommercial Electrical Rough-in 02/24/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 02/26/2014PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 04/21/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved to install the ceiling tiles in all corridors and rooms with grid ceilings.Inspector Comments: 04/23/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final in the north wing-skilled nursing only-electrical.Inspector Comments: Page 4 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary 04/24/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection GFCI protection required for all 125V receptacles in kitchen area.Inspector Comments: 04/25/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Fire Inspection Type 12/18/2013PassBret StoddardFire Alarm Rough-in Approved for cover in gridline 5 to the west in the assisted living wing for electrical and fire alarm wiring and conduit. Inspector Comments: 12/23/2013PassBret StoddardFire Alarm Rough-in Approved for cover in the south side from gridline 5 to 7(assisted living portion) for electrical and fire alarm wiring/conduit. Inspector Comments: 01/16/2014PassBret StoddardFire Alarm Rough-in Approved for cover for electrical and fire alarm wiring in the areas from 0-5 lines on the north portion (skilled nursing wing) in all units, soffits in the 0-7 line (assist. living wing), and room 250 between the two wings hallway. Inspector Comments: 02/05/2014PassBret StoddardFire Alarm Rough-in Approved for cover in resident room #301, hair salon 126, library 124, multipurpose room 122, toilet room 120 and 118, 107, 105, 103, 102, 106, and 104 for electrical and fire alarm wiring/conduit. Inspector Comments: 04/16/2014N/ABret StoddardFire Alarm Final Inspection 04/23/2014PassSAUREY AMANDAFire Sprinkler Rough-in 3/7 Underground flush, Pass, DD 4/7 #220 Hydro, wet, #210 @ 1130, #215 @ 1330 dry, #211 @ 1130, #210 @ 1330 Above grid wet & attic dry, OK to cover, DP Inspector Comments: 04/23/2014PassSAUREY AMANDAFire Sprinkler Final Inspection 04/23/2014PassBret StoddardFire Alarm Final Inspection 05/29/2014PassDale PickeringFire Department Final Inspection Page 5 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary Mechanical Inspection Type 01/16/2014PassQuinton OwensHVAC Rough-in north b wing - mech rough in good.Inspector Comments: 02/11/2014PassQuinton OwensHVAC Rough-in Ductwork over physical therapy area and connecting rooms. Sealed and approved. Inspector Comments: 02/20/2014PassQuinton OwensHVAC Rough-in Walk through for HVAC rough on North side rooms & hall. Approved (finish duct insulation) Inspector Comments: 03/10/2014PassQuinton OwensHVAC Rough-in Grease duct light test. Found 4 initial holes. 2 holes still found at re-inspection. All holes repaired during inspection and duct approved for wrap. Inspector Comments: 03/28/2014PassQuinton OwensHVAC Rough-in 3/25: Grease duct section above roof. Light bulb test in sunlight? or arrange different time. Visual inspection of welds showed potential holes and need to verify. 3/28: Reinspected. holes found (with sunlight outside and inspecting inside duct through access opening) and fixed. Did visual inspection to recheck. Approved Inspector Comments: 04/02/2014PassQuinton OwensHVAC Rough-in Grease duct above roof approved for cover. South portion of mech floor ducts sealed and ready for cover. Inspector Comments: 04/14/2014PassDon AllenHVAC Final Inspection All good for c/oInspector Comments: Page 6 of 7 (Continued) Permit Details Permit Number: 12-00542 410 W 1st N - Carriage Cove Short Stay Rehabilitation 410 W 1st N New Commercial Building Permit Status of (Open) as of Report Date: 03/04/2020 10:34 am Permit Inspection Summary Plumbing Inspection Type 06/07/2013PassDon AllenPlumbing Underground Inspection all good to cover groundworkInspector Comments: 06/27/2013PassDon AllenPlumbing Underground Inspection 07/11/2013PassDon AllenPlumbing Underground Inspection all good to cover ground workInspector Comments: 07/18/2013PassDon AllenPlumbing Underground Inspection good to cover ground work.Inspector Comments: 11/14/2013PassDon AllenPlumbing Rough-in 1/2 south b wing good to coverInspector Comments: 01/21/2014PassDon AllenPlumbing Rough-in north east wing all good to coverInspector Comments: 01/30/2014PassDon AllenPlumbing Rough-in all good on hallways done.Inspector Comments: 02/20/2014FailDon AllenPlumbing Rough-in 02/25/2014PassDon AllenPlumbing Rough-in all goodInspector Comments: 04/14/2014PassDon AllenPlumbing Final Inspection All good for c/oInspector Comments: Page 7 of 7