Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00520 - Summerfield Townhomes #12Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/28/2020 9:52 am Permit Details Permit Number: 12-00520 Summerfield Townhomes #12 913 S 2400 W New Single Family Residence Permit Issued Date: 08/13/2014 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/15/2012PassQuinton OwensResidential Footing Inspection 2 #4 rebar cont. supported. Ufer ground installed at both ends of building.Inspector Comments: 11/16/2012PassQuinton OwensFoundation Inspection OK to pour.Inspector Comments: 03/14/2013FailQuinton OwensResidential Framing/Structure Inspection Fire caulk or drywall over gap behind top plate at firewall.Inspector Comments: 03/18/2013PassQuinton OwensResidential Framing/Structure Inspection Ext Sheething good. *approved. Inspector Comments: 03/18/2013PassQuinton OwensResidential Insulation Inspection Windows = .34 U-factor. Blown fibergalss in exterior & floor over garage. Windows/ Doors sealed. Vent baffles installed. Inspector Comments: 04/02/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection OK to tape drywallInspector Comments: 05/03/2013PassTed DyeSidewalk Inspection approved at time of finalInspector Comments: 05/03/2013FailTed DyeResidential Building Final house number missing grade away from building landscaping left to do Inspector Comments: 05/07/2013PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00520 Summerfield Townhomes #12 913 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 02/28/2020 9:52 am Permit Inspection Summary Electrical Inspection Type 02/20/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-entire building 6 pack-inspected the entire service, inspection ticket is in permit #12-515. Inspector Comments: 03/13/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-inspected unit # 913, 921, and 929, (10, 11, 12) all on the same inspection and wrote only one inspection ticket for all three. Inspector Comments: 05/02/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 03/14/2013PassQuinton OwensHVAC Rough-in Some supply runs ducts have only an R-6 value (r-8 required). Ducts will need to be covered with insulation and inspected. Inspector Comments: 04/30/2013FailDon AllenHVAC Final Inspection Need gas line to water heater. Need clearance in front of furnace (nothing in front) Inspector Comments: 05/16/2013PassDon AllenHVAC Final Inspection all good for the c/o approved 5/1 and 5/2 Inspector Comments: Plumbing Inspection Type 11/29/2012PassDon AllenPlumbing Sewer sewer and water are good to cover.Inspector Comments: 11/29/2012PassDon AllenPlumbing Water sewer and water are good to cover.Inspector Comments: 12/14/2012PassDon AllenPlumbing Underground Inspection 04/09/2013PassDon AllenPlumbing Rough-in all good to coverInspector Comments: 04/30/2013FailDon AllenPlumbing Final Inspection No water to kitchen sink.Inspector Comments: 05/16/2013PassDon AllenPlumbing Final Inspection all good for the c/o Approved 5/1 and 5/2 Inspector Comments: Page 2 of 2