HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00520 - Summerfield Townhomes #12Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/28/2020 9:52 am
Permit Details Permit Number: 12-00520
Summerfield Townhomes #12
913 S 2400 W
New Single Family Residence
Permit Issued Date: 08/13/2014
Permit Inspection Statistics
21Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 80.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
11/15/2012PassQuinton OwensResidential Footing Inspection
2 #4 rebar cont. supported. Ufer ground installed at both ends of building.Inspector Comments:
11/16/2012PassQuinton OwensFoundation Inspection
OK to pour.Inspector Comments:
03/14/2013FailQuinton OwensResidential Framing/Structure Inspection
Fire caulk or drywall over gap behind top plate at firewall.Inspector Comments:
03/18/2013PassQuinton OwensResidential Framing/Structure Inspection
Ext Sheething good.
*approved.
Inspector Comments:
03/18/2013PassQuinton OwensResidential Insulation Inspection
Windows = .34 U-factor.
Blown fibergalss in exterior & floor over garage. Windows/ Doors sealed. Vent
baffles installed.
Inspector Comments:
04/02/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection
OK to tape drywallInspector Comments:
05/03/2013PassTed DyeSidewalk Inspection
approved at time of finalInspector Comments:
05/03/2013FailTed DyeResidential Building Final
house number missing
grade away from building
landscaping left to do
Inspector Comments:
05/07/2013PassTed DyeResidential Building Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00520
Summerfield Townhomes #12
913 S 2400 W
New Single Family Residence
Permit Status of (Open) as of Report Date: 02/28/2020 9:52 am
Permit
Inspection
Summary
Electrical Inspection Type
02/20/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-entire building 6 pack-inspected
the entire service, inspection ticket is in permit #12-515.
Inspector Comments:
03/13/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-inspected unit # 913, 921, and 929, (10, 11, 12) all on the
same inspection and wrote only one inspection ticket for all three.
Inspector Comments:
05/02/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical Inspection Type
03/14/2013PassQuinton OwensHVAC Rough-in
Some supply runs ducts have only an R-6 value (r-8 required). Ducts will need to
be covered with insulation and inspected.
Inspector Comments:
04/30/2013FailDon AllenHVAC Final Inspection
Need gas line to water heater. Need clearance in front of furnace (nothing in
front)
Inspector Comments:
05/16/2013PassDon AllenHVAC Final Inspection
all good for the c/o
approved 5/1 and 5/2
Inspector Comments:
Plumbing Inspection Type
11/29/2012PassDon AllenPlumbing Sewer
sewer and water are good to cover.Inspector Comments:
11/29/2012PassDon AllenPlumbing Water
sewer and water are good to cover.Inspector Comments:
12/14/2012PassDon AllenPlumbing Underground Inspection
04/09/2013PassDon AllenPlumbing Rough-in
all good to coverInspector Comments:
04/30/2013FailDon AllenPlumbing Final Inspection
No water to kitchen sink.Inspector Comments:
05/16/2013PassDon AllenPlumbing Final Inspection
all good for the c/o
Approved 5/1 and 5/2
Inspector Comments:
Page 2 of 2