Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00518 - Summerfield Townhomes #10Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/28/2020 9:29 am Permit Details Permit Number: 12-00518 Summerfield Townhomes #10 929 S 2400 W New Single Family Residence Permit Issued Date: 05/23/2014 Permit Inspection Statistics 19Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 78.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/15/2012PassQuinton OwensFooting Inspection 2 #4 rebar cont. supported. Ufer ground installed at both ends of building.Inspector Comments: 11/16/2012PassQuinton OwensFoundation Inspection Ok to pourInspector Comments: 03/14/2013PassQuinton OwensFraming/Structure Inspection 2/14, QO: Sheathing and hold downs ok to cover Need inspection of Firewall between 10 & 11 at floor joist before drywalling units. 3/13 QO: Firecaulk or drywall behind top plate on north side o last firewall (gap in drywall). -North end unit has some supply ducts with R-6 insulation. (must cover with attic insulation). Inspector Comments: 03/18/2013PassQuinton OwensInsulation Inspection Windows = .34 U-factor. Blown fibergalss in exterior & floor over garage. Windows/ Doors sealed. Vent baffles installed. Inspector Comments: 03/27/2013PassQuinton OwensSheetrock/Drywall Inspection 3/25: Firewall at joist completed.- QO 3/27: 5/8" on fire walls and bottom of trusses. Inspector Comments: 04/30/2013FailTed DyeBuilding Final Smoke's not talking with each other hall to bedrooms.Inspector Comments: 05/02/2013FailTed DyeBuilding Final Grade away from building Landscaping left to do Hole in ceiling of pantry. Inspector Comments: 05/03/2013PassTed DyeSidewalk Inspection 05/07/2013PassTed DyeBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00518 Summerfield Townhomes #10 929 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 02/28/2020 9:29 am Permit Inspection Summary Electrical Inspection Type 02/20/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-entire building 6 pack-inspected the entire service, inspection ticket is in permit #12-515. Inspector Comments: 03/13/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-inspected unit # 913, 921, and 929, (10, 11, 12) all on the same inspection and wrote only one inspection ticket for all three. Inspector Comments: 04/19/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-units 953, 945, 937 and 929 only-inspected all these units on the same inspection and ticket. Inspector Comments: Mechanical Inspection Type 04/30/2013FailDon AllenHVAC Final Inspection Need to vent water heater Need proper clearance in front of furnace. Inspector Comments: 05/01/2013PassDon AllenHVAC Final Inspection all good for the c/o.Inspector Comments: Plumbing Inspection Type 11/29/2012PassDon AllenPlumbing Water water ok to coverInspector Comments: 11/29/2012PassDon AllenPlumbing Sewer Sewer ok to cover.Inspector Comments: 12/15/2012PassDon AllenPlumbing Underground Inspection 04/30/2013FailDon AllenPlumbing Final Inspection need cap on softener drain.Inspector Comments: 05/01/2013PassDon AllenPlumbing Final Inspection all good for the c/o.Inspector Comments: Page 2 of 2