Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00517 - Summerfield Townhomes #9Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/28/2020 9:03 am Permit Details Permit Number: 12-00517 Summerfield Townhomes #9 937 S 2400 W New Single Family Residence Permit Issued Date: 08/06/2014 Permit Inspection Statistics 20Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 80.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/15/2012PassQuinton OwensResidential Footing Inspection 2 #4 rebar cont. supported. Ufer ground installed at both ends of building.Inspector Comments: 11/16/2012PassQuinton OwensFoundation Inspection OK to pour.Inspector Comments: 03/07/2013FailQuinton OwensResidential Framing/Structure Inspection 2/14, QO: Sheathing and hold downs ok to cover Holes too large in bearing wall between kitchen and storage pantry. Keep firewall continuity at floor joist between #8 & #9. Overburn and inner firewall ok. Inspector Comments: 03/12/2013FailQuinton OwensResidential Insulation Inspection Seal duct around bottom truss chord penetration. Finish fire caulk in #8 above bathtub. Inspector Comments: 03/12/2013PassQuinton OwensResidential Insulation Inspection 03/14/2013PassQuinton OwensResidential Framing/Structure Inspection 03/20/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection OK to tape drywall.Inspector Comments: 05/01/2013FailTed DyeResidential Building Final Missing address on outside of building grade away from building .landscaping left to do ***plumbing and mech. left to pass off Inspector Comments: 05/03/2013PassTed DyeSidewalk Inspection 05/07/2013PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00517 Summerfield Townhomes #9 937 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 02/28/2020 9:03 am Permit Inspection Summary Electrical Inspection Type 02/20/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-entire building 6 pack-inspected the entire service, inspection ticket is in permit #12-515. Inspector Comments: 03/08/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 04/19/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-units 953, 945, 937 and 929 only-inspected all these units on the same inspection and ticket. Inspector Comments: Mechanical Inspection Type 03/07/2013FailQuinton OwensHVAC Rough-in Finish up rough-in. secure b-vent and provide clearances. Seal duct around bottom truss chord penetration. *Approved in Final Inspector Comments: 05/16/2013PassDon AllenHVAC Final Inspection all good for the c/oInspector Comments: Plumbing Inspection Type 11/29/2012PassDon AllenPlumbing Sewer sewer and water are good to cover.Inspector Comments: 11/29/2012PassDon AllenPlumbing Water sewer and water are good to cover.Inspector Comments: 12/14/2012PassDon AllenPlumbing Underground Inspection 03/26/2013PassDon AllenPlumbing Rough-in 05/16/2013PassDon AllenPlumbing Final Inspection 4/30/13 - Need to cap softner drain. all good for the c/o Inspector Comments: Page 2 of 2