HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00515 - Summerfield Townhomes #7Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/28/2020 9:01 am
Permit Details Permit Number: 12-00515
Summerfield Townhomes #7
953 S 2400 W
New Single Family Residence
Permit Issued Date: 08/12/2014
Permit Inspection Statistics
21Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 71.43%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
11/15/2012PassQuinton OwensResidential Footing Inspection
Layout good. (per eng'r stakes)
2 #4 rebar cont. supported. Ufer ground installed at both ends of building.
Inspector Comments:
11/16/2012PassQuinton OwensFoundation Inspection
OK to pour.Inspector Comments:
03/07/2013FailQuinton OwensResidential Framing/Structure Inspection
2/14, QO: Sheathing and hold downs ok to cover
Holes too large in bearing wall between kitchen and storage pantry.
Overburn and inner firewall ok.
Inspector Comments:
03/12/2013PassQuinton OwensResidential Framing/Structure Inspection
03/12/2013FailQuinton OwensResidential Insulation Inspection
Seal duct around bottom truss chord penetration. Finish fire caulk in #8 above
bathtub.
Inspector Comments:
03/12/2013PassQuinton OwensResidential Insulation Inspection
03/18/2013PassTed DyeResidential Sheetrock/Drywall Inspection
Screw patterns good
5/8 fire code rock in proper locations
Ok to tape
Inspector Comments:
04/23/2013FailQuinton OwensResidential Building Final
4/23, QO: Finish ext. concrete. and install correct front door. (currently a temp
door)
Inspector Comments:
05/07/2013PassTed DyeResidential Building Final
Electrical Inspection Type
02/20/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-entire building 6 pack.Inspector Comments:
03/08/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover.Inspector Comments:
04/19/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-units 953, 945, 937 and 929 only-inspected all
these units on the same inspection and ticket.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00515
Summerfield Townhomes #7
953 S 2400 W
New Single Family Residence
Permit Status of (Open) as of Report Date: 02/28/2020 9:01 am
Permit
Inspection
Summary
Mechanical Inspection Type
03/07/2013FailQuinton OwensHVAC Rough-in
Finish up rough-in. secure b-vent and provide clearances.Inspector Comments:
03/12/2013FailQuinton OwensHVAC Rough-in
seal duct around bottom chord penetration.
1" clearance around B-vent (insulated ducts and roof sheathing)
Inspector Comments:
04/23/2013FailQuinton OwensHVAC Final Inspection
Secure gas line where penetrates floor in mech. room.Inspector Comments:
05/16/2013PassDon AllenHVAC Final Inspection
all good for the c/oInspector Comments:
Plumbing Inspection Type
11/29/2012PassDon AllenPlumbing Sewer
sewer and water are good to cover.Inspector Comments:
11/29/2012PassDon AllenPlumbing Water
sewer and water are good to cover.Inspector Comments:
12/14/2012PassDon AllenPlumbing Underground Inspection
02/26/2013PassDon AllenPlumbing Rough-in
All good to cover.Inspector Comments:
05/16/2013PassDon AllenPlumbing Final Inspection
all good for the c/oInspector Comments:
Page 2 of 2