Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00516 - Summerfield Townhomes #8Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/28/2020 9:00 am Permit Details Permit Number: 12-00516 Summerfield Townhomes #8 945 S 2400 W New Single Family Residence Permit Issued Date: 08/12/2014 Permit Inspection Statistics 23Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 69.57% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/15/2012PassQuinton OwensResidential Footing Inspection 2 #4 rebar cont. supported. Ufer ground installed at both ends of building.Inspector Comments: 11/16/2012PassQuinton OwensFoundation Inspection OK to pour.Inspector Comments: 03/07/2013FailQuinton OwensResidential Framing/Structure Inspection 2/14, QO: Sheathing and hold downs ok to cover. Holes too large in bearing wall between kitchen and storage pantry. Keep firewall continuity at floor joist between #8 & #9. Overburn and inner firewall ok. Inspector Comments: 03/12/2013FailQuinton OwensResidential Framing/Structure Inspection Voids in firecaulk in #8 above bathtub. Need inspection of Firewall between 8 & 9 at floor joist before drywalling units. Inspector Comments: 03/12/2013FailQuinton OwensResidential Insulation Inspection Seal duct around bottom truss chord penetration. Finish fire caulk in #8 above bathtub. Inspector Comments: 03/12/2013PassQuinton OwensResidential Insulation Inspection 03/14/2013PassQuinton OwensResidential Framing/Structure Inspection 03/18/2013PassTed DyeResidential Sheetrock/Drywall Inspection patterns look good. 5/8 fire code rock where needed. OK to tape.Inspector Comments: 04/23/2013FailQuinton OwensResidential Building Final House 3s not installed. Finish front door installation (not sealed-temp door installed). Front concrete work not done. Inspector Comments: 04/29/2013FailTed DyeResidential Building Final smoke's not talking with each other hall to bedroom.Inspector Comments: 05/01/2013PassTed DyeSidewalk Inspection 05/02/2013FailTed DyeResidential Building Final grade away from building. Landscaping to do.Inspector Comments: 05/07/2013PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00516 Summerfield Townhomes #8 945 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 02/28/2020 9:00 am Permit Inspection Summary Electrical Inspection Type 02/20/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-entire building 6 pack-inspected the entire service, inspection ticket is in permit #12-515. Inspector Comments: 03/08/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 04/19/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-units 953, 945, 937 and 929 only-inspected all these units on the same inspection and ticket. Inspector Comments: Mechanical Inspection Type 03/07/2013FailQuinton OwensHVAC Rough-in Finish up rough-in. secure b-vent and provide clearances.Inspector Comments: 04/23/2013PassQuinton OwensHVAC Final Inspection Gas line connector for furnace crosses in front of access panel. Line should be place to allow service to furnace without disconnecting gas line. This one should be ok for removing panel and servicing. Inspector Comments: Plumbing Inspection Type 11/29/2012PassDon AllenPlumbing Sewer sewer and water are good to cover.Inspector Comments: 11/29/2012PassDon AllenPlumbing Water sewer and water are good to cover.Inspector Comments: 12/14/2012PassDon AllenPlumbing Underground Inspection 03/26/2013PassDon AllenPlumbing Rough-in all good to cover roughinInspector Comments: 05/16/2013PassDon AllenPlumbing Final Inspection all good for the c/oInspector Comments: Page 2 of 2