Permit Status of (Open) as of Report Date: 02/25/2020 11:43 am
Permit Details Permit Number: 12-00469
Central Park Apts 2
450 W 4th S
New Multi-Family Residence
Permit Issued Date: 08/12/2014
Permit Inspection Statistics
29Total Inspections Completed:
20Total Inspections Passed:
Inspection Pass Rate: 68.97%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
12/07/2012PassQuinton OwensResidential Footing Inspection
11-19 (QO) Support wires being done. Clean any excess dirt off rebar. Eagle Rock
on site for special inspections. North, East, and partial South footing ready to
pour. 2- #4 cont.
12/7: Partial South & West ftg - 2 #4 rebar cont.OK to pour
3/7: Spot footings for exterior balcony. 4 #4 each way (middle and east
bldg).Approved.
3/12: Piers: OK to pour
3/29: Spot ftgs (west side) approved for pour.
7/17 East footing on west side rebar overlaps good, held off of ground Approved.
Inspector Comments:
12/12/2012PassQuinton OwensFoundation Inspection
11/30, QO: North Wall - West half. 3 horiz. cont. and vert. @ 18" oc (all #4).
12/12: South & West wall. 3 #4 horiz & Vert.#4 at 18" oc
3/12: Piers for balcony - 4 vert. #4 rebar & #3 rings (1 at bottom, 3 at top)
7/23/13: Storage bldg in west parking lot. (3 #4 horiz. & #4 vert. at 18" oc)
-approved.
Inspector Comments:
03/19/2013FailQuinton OwensResidential Framing/Structure Inspection
West end section sheathing: A few locations not nailed (marked with crayon)
3/19, QO: Oversized holes in bearing studs, Joists "destroyed" in middle 2 units
(2nd flr), oversized holes in kitchen (non-bearing) wall, some sheathing missed.
Inspector Comments:
03/28/2013FailQuinton OwensResidential Insulation Inspection
Doors and windows not sealed. Cut insulation batts to fit smaller stud cavities.
R30 batt layed flat does not fill depth of joist at ext.wall. weather barrier at
raised trusses to keep insulation in place and protect from wind through soffit.
Inspector Comments:
Page 1 of 4
(Continued)
Permit Details Permit Number: 12-00469
Central Park Apts 2
450 W 4th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/25/2020 11:43 am
Permit
Inspection
Summary
05/01/2013PassTed DyeResidential Framing/Structure Inspection
As per Quinton Owens
3/22, QO: Middle bldg reinspect approved for insulation.
4/10,QO: East section. Rating will be required behind washer hookups in laundry
room.
5/1 West end units passed (301through304) And(401 Through 404)
Inspector Comments:
05/06/2013PassQuinton OwensResidential Insulation Inspection
4/3, QO: Middle building approved for drywall. Windows/doors sealed. Vent
baffles installed in attic. Exterior floor cavities filled.
4/18,QO: East bldg ok to drywall. Walls=R19, Windows U.34, Floor=R30.
Window/doors sealed. Vent baffles installed for venting and containing insulation.
5/3,QO: West Section - Open top of vent baffles for ventilation, Top floor bath
vents not firecaulked. (Reinspected and approved 5/6) Metal covers needed on
non-rated boxes in fire partitions.
5/15: Storage rooms at stairs disapproved. Seal around doors. Insulate floor
joists at exterior. Void in attic insulation in back corner.
5/17: Storage rooms approved.
Inspector Comments:
05/15/2013FailQuinton OwensResidential Insulation Inspection
Storage Units: Seal around doors. Insulate ext. at floor joist. Void attic insul. at
back corner.
Inspector Comments:
05/22/2013FailQuinton OwensResidential Sheetrock/Drywall Inspection
5/22,QO: Last unit (used to store doors in) some locations without 1 hour rating.
Storage units also need 1hr on wall next to stairwell.
Inspector Comments:
06/26/2013FailQuinton OwensResidential Sheetrock/Drywall Inspection
6/26,QO: Laundry room and room above- Access opening required for regulator.
F.C. around pipe and dryer vents penetrating fire partition.OK to tape
Inspector Comments:
06/26/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection
4/24, QO: East end bldg, Fire partitions 1 hr as required. approved for taping
5/9, west section. non fire rated boxes in party walls and upper level ceilings
will require metal covers. OK for taping west wing.
5/23,QO: Wall fire rating fixed as required (last apt and storage rooms
approved).East wall in apt. has 5/8" regular drywall w/ sheathing (1 hr calculated
per IBC 721) Laundry room left to inspect.
Inspector Comments:
07/09/2013FailQuinton OwensResidential Building Final
Bathrm cabinets extend too far over toilets? Fire rating needed at Data/TV covers
(or rated box). Water hookups behind toilets to have metal escutcheons or
firecaulk. Firecaulking not done in mech room. Apt #'s missing.
Inspector Comments:
07/12/2013FailQuinton OwensResidential Building Final
All good EXCEPT laundry room, and storage/data room on east end (upper floor)
and storage rooms off stair wells and data line boxes in fire partitions.
Inspector Comments:
Page 2 of 4
(Continued)
Permit Details Permit Number: 12-00469
Central Park Apts 2
450 W 4th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/25/2020 11:43 am
Permit
Inspection
Summary
08/29/2014PassQuinton OwensResidential Building Final
Previous items completed.Inspector Comments:
08/29/2014PassQuinton OwensSidewalk Inspection
Electrical Inspection Type
03/22/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-slip couplings (expansion fittings)
installed (4).
Inspector Comments:
05/02/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
3/20/13 - Approved for cover in the three level section only-12 units-middle
portion.
4/15/13 - Approved for cover in the east 8 units only, smoke detectors are not
installed in the ADA unit on the bottom level far east unit that will need to be tied
into the fire alarm system(2 smokes).
5/2/13 - Approved for Cover - west 8 units.
Inspector Comments:
07/10/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-electrical and fire alarm on same
inspection-7/9&7/10/13.
Inspector Comments:
Fire Inspection Type
03/28/2013PassDale PickeringFire Sprinkler Rough-in
3/18/13 - OK to cover East and central buildings.
3/28/13 - OK to cover.
Inspector Comments:
06/26/2013PassDale PickeringFire Sprinkler Hydro
10.00 - 205#
12.25 - 205#
Inspector Comments:
07/10/2013PassBret StoddardFire Alarm Final Inspection
Approved for a final and C.O. fire alarm and electrical-witnessed 24 hour 5
minute test, flow and tamper switch operation, Omni's report is attached and in
the file-7/9&7/10/13.
Inspector Comments:
Page 3 of 4
(Continued)
Permit Details Permit Number: 12-00469
Central Park Apts 2
450 W 4th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/25/2020 11:43 am
Permit
Inspection
Summary
Mechanical Inspection Type
05/21/2013FailQuinton OwensHVAC Rough-in
shutoff valves before regulator and access opening in laundry (Metal for rating).
No screws allowed in dryer vents.
9-11-13 Covered parking sheeting inspection Approved
Inspector Comments:
06/11/2013PassQuinton OwensHVAC Rough-in
6/11,QO: laundry room: Screws removed from dryer vent.Inspector Comments:
07/09/2013FailQuinton OwensHVAC Final Inspection
Gas line extended into Mech room not tested.Inspector Comments:
07/26/2013PassQuinton OwensHVAC Final Inspection
Checked gas piping inside mechanical room with elect. gas detector. No leaks
found.
Inspector Comments:
Plumbing Inspection Type
10/10/2012PassDon AllenPlumbing Water
All good to cover.Inspector Comments:
10/10/2012PassDon AllenPlumbing Sewer
12/21/2012PassDon AllenPlumbing Underground Inspection
05/28/2013PassDon AllenPlumbing Rough-in
4/10/13 - *approved
4/23/13 - *approved
Inspector Comments:
07/09/2013PassDon AllenPlumbing Final Inspection
Need to finish but what is done looks good.Inspector Comments:
Page 4 of 4