Permit Details Permit Number: 12-00444
182 S Colene Dr., Rigby - SFR
182 South Colene Drive, Rigby
Single Family Residence Rigby
Permit Issued Date: 08/05/2014
Permit Inspection Statistics
21Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 76.19%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
10/17/2012PassQuinton OwensResidential Footing Inspection
10/17/12 - Layout - OK per Rigby Standards
2 rebar cont. & supported
Inspector Comments:
10/18/2012PassQuinton OwensFoundation Inspection
Horizontal rebar in middle and top. Verticals at 24" o.c.
Ufer installed.
OK to pour
Inspector Comments:
11/01/2012PassQuinton OwensResidential Framing/Structure Inspection
Wall Sheeting - OK to cover. Missed areas fixed during insp.Inspector Comments:
11/09/2012FailQuinton OwensResidential Framing/Structure Inspection
Damaged Joist under bathtub. Manuf'r approved fix required.Inspector Comments:
11/13/2012FailQuinton OwensResidential Insulation Inspection
Blown cellulose in walls. No labels on windows for U-factors. R-11 insulation on
basement walls.instead of R-13 min. New REScheck needed for approval.
Inspector Comments:
11/15/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
11/28/12 - Sheetrock Disapproved - 5/8 needed in bathroom party wall and in
living room closet around elect panel. Finish sealing around windows.
11/14/12 - Drywall OK to tape. (11/15)
Inspector Comments:
11/21/2012PassQuinton OwensResidential Insulation Inspection
New REScheck approved. Verify furnace is 95% efficient.Inspector Comments:
12/18/2012FailQuinton OwensResidential Building Final
CO detector required outside sleeping rooms. Egress ladder from basement.
Handrail required in garage (4 risers)
Inspector Comments:
07/05/2013FailQuinton OwensResidential Building Final
Garage handrail not terminating at post.Inspector Comments:
07/09/2013PassQuinton OwensResidential Building Final
Final done (building)Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00444
182 S Colene Dr., Rigby - SFR
182 South Colene Drive, Rigby
Single Family Residence Rigby
Permit Status of (Open) as of Report Date: 02/19/2020 11:18 am
Permit
Inspection
Summary
Electrical Inspection Type
11/08/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in therefore no separate ticket was written.
Inspector Comments:
11/08/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-unfinished basement entirely-also inspected the service on
this inspection.
Inspector Comments:
12/18/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement entirely.Inspector Comments:
Mechanical Inspection Type
11/09/2012FailQuinton OwensHVAC Rough-in
Seal return air plenums in walls. Connect supply duct to boot (Under bathtub).
Seal Return air plenums in floor - around water lines, and dryer vent locations.
Inspector Comments:
11/13/2012PassQuinton OwensHVAC Rough-in
07/05/2013PassQuinton OwensHVAC Final Inspection
Mech final approved.Inspector Comments:
Plumbing Inspection Type
10/26/2012PassDon AllenPlumbing Underground Inspection
good to cover groundwork.Inspector Comments:
10/31/2012PassDon AllenPlumbing Sewer
main line is good to cover on sewer, need to check the hookup to the house.Inspector Comments:
10/31/2012PassDon AllenPlumbing Water
11/15/2012PassDon AllenPlumbing Rough-in
All good to cover roughin.Inspector Comments:
12/21/2012PassDon AllenPlumbing Final Inspection