HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00399 - Mesa Falls Apts Bldg # 1Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/19/2020 9:08 am Permit Details Permit Number: 12-00399 Mesa Falls Apts Bldg # 1 940 S 5th W New Multi-Family Residence Permit Issued Date: 02/27/2014 Permit Issued Date: 05/20/2015 Permit Inspection Statistics 27Total Inspections Completed: 24Total Inspections Passed: Inspection Pass Rate: 88.89% Permit Inspection History *Refer to Individual Inspection Report for more Details 05/24/2013PassDale PickeringFire Underground Inspection Underground hydro - bldgs 6,1,15,16 all pass.Inspector Comments: Building Inspection Type 04/16/2013PassTed DyeFoundation Inspection Middle section approved. (outside foundation to be inspected)Inspector Comments: 04/17/2013PassQuinton OwensFoundation Inspection 4/17, QO: outer buildings approved to pour. Ufer placed in footing after inspection. Inspector Comments: 05/09/2013PassQuinton OwensFooting Inspection 2 #4 rebar cont. and supported. clearances good. Ufer not in at time of inspection. 5/9, QO: Interior footings - 2 #4 rebar supported on chairs. Inspector Comments: 8/8,QO: Finish firecaulking interior wall plates (mainly at dryer vents and phone line). Fireblock plate penetrations in rated walls. Add stud by door to laundry (305). Fix clg joist in lndry (306). Inspector Comments: 8/21,QO: 2nd Floor - finish Fireclk (205,208,202,203). Bad stud in bearing wall (205). Fireclk penetrations into rated washer box area (203,206). Fire caulk tub drain above 201. Inspector Comments: 8/23,QO: previous items not completed- Frclk & frblk, add stud by laundry (305) Inspector Comments: 8/27, TD: 1st floor - open hope (101 hole filled with fire block, need's caulk), concealed area above tum rm101 drywall hanging & rm108 Inspector Comments: 8/29,QO: 2nd & 3rd Floor items done.(sent Ted for re-inspection)Inspector Comments: 8/29 TD: 2nd floor - 208 seal around patio door (DA)Inspector Comments: 08/30/2013PassQuinton OwensFraming/Structure Inspection 8/30/13 TD: rm. 101 Approved , 208 approvedInspector Comments: 08/30/2013PassQuinton OwensInsulation Inspection 8/23,QO: 3rd Floor approved. 8/27,QO: 2nd Floor - Seal around patio doors. 8/29,QO: All floors done. Inspector Comments: 8/27,QO: 3rd Floor, 5/8" type x required on walls dividing vaulted space and attic space in addition to fire partitions.(corrected 8/30,QO) Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00399 Mesa Falls Apts Bldg # 1 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/19/2020 9:08 am Permit Inspection Summary 8/29 QO: 1st floor insuation good. r-19 walls (ext.) r-13 int. walls, v-.34 windows, floor- blown fbrgls wndow/dr perm. sealed. Inspector Comments: 8/30/13 208,207,205,and 206 approved for taping 207 had one side missing screws they did them shortly after i inspected it. Inspector Comments: 9/4,QO: 1st floor approved.Inspector Comments: 12/26/2013PassQuinton OwensSheetrock/Drywall Inspection 8/30 TD: 208 - drywall approved taping. 207 - drywall screws missing kitchen area. 205- drywall approved for taping. 206- need shear wall and drywall. Inspector Comments: 12/26/2013PassTed DyeSidewalk Inspection 12/30/2013PassTed DyeBuilding Final 1101through 108 passed final 1201 through 208 passed final 1301 through 308 passed final Inspector Comments: 02/27/2014PassPLL ADMINFraming/Structure Inspection 7/2,QO: Sheathing- missed nailing at marked locations. (Reinspect with Framing)Inspector Comments: Electrical Inspection Type 08/05/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power(2 locations)-inspected the electrical services on the rough-in inspection. Inspector Comments: 08/05/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover entire building-inspected the electrical service and fire alarm wiring on this inspection. Inspector Comments: 12/12/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-electrical only.Inspector Comments: Fire Inspection Type 08/05/2013PassBret StoddardFire Alarm Rough-in Approved for cover entire building-fire alarm wiring-inspected on the same inspection as the electrical wiring. Inspector Comments: 09/06/2013PassDale PickeringFire Sprinkler Hydro Bldg # 1; Hydro at #200 psi - PassInspector Comments: 12/19/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-fire alarm only, witnessed all signalling and initiating device operation, 24 hour/5minute test from 3:15PM 12/18 to 3:30PM 12/19 for AC restored, flow switch(36 seconds) and tamper switches(2) operational-witnessed, panel had 2 hour delay for AC loss because of dip switch #6 on panel as per Gary with Omni, report in file. Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00399 Mesa Falls Apts Bldg # 1 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/19/2020 9:08 am Permit Inspection Summary Mechanical Inspection Type 08/29/2013PassQuinton OwensHVAC Rough-in 8/8,QO: fix separation in bath vent (301). B-vents not finished. Dryer vents very long (post effective dryer length). 8/21,QO: 2nd Floor- firecaulk gaps at B-vent at ceiling leve (207,204,201) & wall (201,208). 3rd floor done. 8/23,QO: Post effective dryer lengths before final. 8/27,QO: 1st floor-seal plenums (101,102,106). Finish 2nd floor items. 8/29,QO: 1st & 2nd floor done. Inspector Comments: 12/20/2013FailQuinton OwensHVAC Final Inspection Gas odor by regulator in 1102,1301, and 1108. Fix bath fan in 1203. Hazard: strap for water heater by light switch in pantry (middle units) might cut someone's hand when reaching for the switch. Don't lose tags to regulators; they need to stay on them. Inspector Comments: 12/27/2013PassQuinton OwensHVAC Final Inspection 12/24: Gas odor still by regulator in 1301. 12/27: all units approved. Inspector Comments: Plumbing Inspection Type 04/29/2013PassDon AllenPlumbing Underground Inspection all good to cover groundworkInspector Comments: 05/28/2013PassDon AllenPlumbing Underground Inspection 07/16/2013FailDon AllenPlumbing Rough-in need to strap the water lines ever 32"Inspector Comments: 07/17/2013FailDon AllenPlumbing Water need to install the y straner and the meter need to strap the water lines ever 32" Inspector Comments: 12/18/2013PassDon AllenPlumbing Final Inspection all good for the C/OInspector Comments: 12/24/2013PassDon AllenPlumbing Sewer 12/24/2013PassDon AllenPlumbing Water 12/24/2013PassDon AllenPlumbing Rough-in Page 3 of 3