Permit Status of (Open) as of Report Date: 02/18/2020 4:17 pm
Permit Details Permit Number: 12-00397
Mesa Falls Apts Bldg #17
940 S 5th W
New Multi-Family Residence
Permit Issued Date: 03/01/2014
Permit Inspection Statistics
22Total Inspections Completed:
20Total Inspections Passed:
Inspection Pass Rate: 90.91%
Permit Inspection History *Refer to Individual Inspection Report for more Details
11/19/2013Pass Fire Underground Inspection
Building Inspection Type
04/08/2013PassQuinton OwensFooting Inspection
2 #4 rebar cont. and supported. Clearances OK. Clean dirt out of corners inside
footings. Dowels being cut. (4/9, saw imprints of bends in dowels in footing).
4/24,QO: Interior footings in (slab) - missed inspection (ok to pour typ.
supported on chairs)
Inspector Comments:
4/9 QO: Middle section: 3 #4 rebar cont. OK to pour. Verticals installed (forgot to
verify spacing).
spacing distance verified to make sure subcontractor new the spacing
Inspector Comments:
4/10 TD: overlaps good, spacing good.Inspector Comments:
05/15/2013PassTed DyeFoundation Inspection
4/24 QO: Floor slab w/int footing *did not inspect*Inspector Comments:
07/24/2013Pass Framing/Structure Inspection
6/18 QO: nail off missed sheeting at marked locations. *DA*
Action required: ok to cover, will reinspect with framing. (no siding yet).
7/16 TD: top floor
7/18 TD: 2nd floor - approved.
7/19 TD: 2nd floor fire caulking and fire caulking
main floor: complete separation between units in floor trusses and in floor joist.
fire caulk and fire stop OK
Shear walls good missing some fire caulk.
7/24 TD: some fire caulk missing
Inspector Comments:
07/31/2013Pass Sheetrock/Drywall Inspection
Sheetrock inspection 2nd floor OK
306 and 307 not complete
Apt. 3 on first floor hung and taped.
build.17: rooms 7 and 8 ok to drywall
sheetrock 1st floor rooms 5 and 6 OK
Inspector Comments:
Page 1 of 4
(Continued)
Permit Details Permit Number: 12-00397
Mesa Falls Apts Bldg #17
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 4:17 pm
Permit
Inspection
Summary
11/19/2013Pass Building Final
17101.......Passed
102 Water heater strap needs attached .........Passed
103 Fire caulk around dryer exhaust pipe and wall opening.......Passed
104 .....Passed
105 Exhaust fan...........Passed
106 Fire caulk around dryer vent..........Passed
107 Water heater strap......Passed
108 .....Passed
201..... Passed
202......Passed
203 Firecaulk around dryer vent...........Passed
204.....Passed
205.....Passed
206.....Passed
207 .....Passed
208 Water heater strap.........Passed
301....Passed
302.....Passed
303 Water heater Strap........Passed
304 Water heater Strap......Passed
305.......Passed
306 fire caulk around dryer vent........Passed
307......Passed
308......Passed
Inspector Comments:
03/01/2014Pass Insulation Inspection
third floor insulation ApprovedInspector Comments:
Page 2 of 4
(Continued)
Permit Details Permit Number: 12-00397
Mesa Falls Apts Bldg #17
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 4:17 pm
Permit
Inspection
Summary
Electrical Inspection Type
07/17/2013Pass COM & MFR Electrical Service Inspection
Approved to be energized for permanent power-(2 locations), inspected the
electrical service on the rough-in inspection.
Inspector Comments:
07/17/2013Pass Commercial Electrical Rough-in
7/17 BS: Approved for cover in the south portion of the building, also inspected
the electrical service on this inspection, also inspected the fire alarm wiring.
Inspector Comments:
07/17/2013Pass Commercial Electrical Rough-in
7/17 BS:Approved for cover-electrical and fire alarm wiring in the north
portion(half) of the building-made 2 trips out because not ready.
Inspector Comments:
11/06/2013Fail COM, COM-A, COM-R, and COM-T Electrical Final Inspection
Blank cover 17104 for cable heating in ceiling-sprinkler abandoned and panel
cover screws missing, breezeway not GFCI protected 17102, furnace unwired
17201, GFCI kitchen won't reset 17303, disposeall wire screwed 17302, GFCI
kitchen no power 17107, GFCI kitchen won't test 17105, breaker blanks needed
17205, GFCI kitchen missing 17206, no GFCI and won't reset 17306, call for a
re-inspect when ready.
Inspector Comments:
11/07/2013Pass COM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O.-items were corrected.Inspector Comments:
Fire Inspection Type
11/12/2013Pass Fire Alarm Final Inspection
Approved for a final and C.O., flow switch triggered system in 39 seconds,
witnessed all initiating and signalling devices operation, witnessed monitoring and
history via Troy's cell phone to Avantguard, 24 hour /5 minute test from 3:15PM
11/11 to 3:17PM 11/12, report in file.
Inspector Comments:
11/19/2013Pass Fire Sprinkler Rough-in
11/19/2013Pass Fire Sprinkler Final Inspection
Page 3 of 4
(Continued)
Permit Details Permit Number: 12-00397
Mesa Falls Apts Bldg #17
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 4:17 pm
Permit
Inspection
Summary
Mechanical Inspection Type
07/22/2013Pass HVAC Rough-in
7/19 DA: need 1" clearance around water heater vents.
7/22 DA: NW apt bottom water heater vent.
Inspector Comments:
11/12/2013Fail HVAC Final Inspection
need to take off tape and pins/put on.
need to support 6 gas in mech. room
105 exhaust fan doesn't work.
107,108,102,104 need to fill gaps on fire caulk on water heater vent.
206 needs 1" clearance around water heater vent
305 need to finish a bash fail
Inspector Comments:
11/15/2013PassPLL ADMINHVAC Final Inspection
all good for c/oInspector Comments:
Plumbing Inspection Type
05/28/2013Pass Plumbing Underground Inspection
4/29 DA: all good to cover groundwork
5/28 DA: all good to cover the ground work
Inspector Comments:
07/22/2013Pass Plumbing Sewer
07/22/2013Pass Plumbing Rough-in
6/26 DA: good to cover rough in.Inspector Comments:
09/03/2013Pass Plumbing Water
11/12/2013Pass Plumbing Final Inspection
all good for c/oInspector Comments: