HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00394 - Mesa Falls Apts Bldg #4Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm Permit Details Permit Number: 12-00394 Mesa Falls Apts Bldg #4 940 S 5th W New Multi-Family Residence Permit Issued Date: 02/18/2014 Permit Inspection Statistics 43Total Inspections Completed: 36Total Inspections Passed: Inspection Pass Rate: 83.72% Permit Inspection History *Refer to Individual Inspection Report for more Details 02/24/2014PassTed DyeSheetrock/Drywall Inspection nail patterns good ok to tape Inspector Comments: 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection 02/24/2014PassTed DyeSheetrock/Drywall Inspection Page 1 of 5 (Continued) Permit Details Permit Number: 12-00394 Mesa Falls Apts Bldg #4 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm Permit Inspection Summary Building Inspection Type 06/06/2013PassQuinton OwensFoundation Inspection 6/5,QO: Middle bldg. - #4 vertical bars at ~18" oc. and 2 #4 bars cont. (approved) 6/6,QO: Side bldgs same. (Ufer bar added to footings) Inspector Comments: 06/20/2013PassQuinton OwensFooting Inspection 6/4 - 2 #4 bars cont. 6/20 - Ok to pour Inspector Comments: 10/03/2013FailTed DyeFraming/Structure Inspection 4 103 Missed nailing sheeting to studs 4 201 " " 4 202 " " Btm Plate 4 204 " " " " 4 305 " " 4 306 " " " " 4 307 " " 4 106 " " Inspector Comments: 11/29/2013PassTed DyeFraming/Structure Inspection 01/09/2014PassQuinton OwensFraming/Structure Inspection 1/9/13 QO: Framing (101-104) - 101: Firecaulk gas line at water heater, fix laundry room wall & stud at mst. bth/closet. Firecaulk gas line by water heater (typical). Holes for return air cut into headers. Firecaulk open gaps at fire sprnklr crossover. 2 layers at ceiling above fireplace (1hr rated) fire caulk no complete above elec. panel (103). *will try to finish bldg 3 on fri (1-10) for inspection. Inspector Comments: 02/04/2014PassTed DyeFraming/Structure Inspection 4301, 302, 303, 304, 305, 306 308, 307 more insulation needed above windows. Mark orange. Inspector Comments: 02/06/2014FailTed DyeInsulation Inspection Insulation (bottom 2 floors) - Approved 4101, 102, 201, 202, 203, 204, 205, 206, 207, 105, 106, 107, 108. 104 &103 exhaust fan miss in bathroom and wires hanging out of ceiling. Inspector Comments: 02/11/2014Pass Sheeting 4013 one side of sheeting not nailed, finished while there. check exhaust fans ok. Inspector Comments: 02/19/2014FailQuinton OwensSheetrock/Drywall Inspection 3rd and 2nd floor on South end approved for taping and Apt 108. Finish drywall at dryer vent box for final (306,206,303). l" Clearance missing around b-vent (305,308, 108,206,205,307, 207,208, 304). Missed screws 301 (next to door going to laundry room, in closet facing front door, along ceiling edge in East bdrm), 304 (on wall above stove, at vertical joint by sliding door),303 (by bthrm sink). 1st floor not done except 108. 2nd floor North not done. Inspector Comments: Page 2 of 5 (Continued) Permit Details Permit Number: 12-00394 Mesa Falls Apts Bldg #4 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm Permit Inspection Summary 03/26/2014PassTed DyeInsulation Inspection 05/28/2014FailTed DyeBuilding Final ******(Typ.) All units : Tighten all compression nuts on hot water heater drain pans**************** -4101 every thing else OK -4102 everything else OK -4103 Replace B vent top strap of water heater missing Seal off dryer vent cavity -4104 Position condensate drain over drain -4201 Every thing else OK -4202 Every thing else OK -4203 Seal off dryer vent cavity -4204 Everything else OK -4301 Every thing else OK -4302 !" needed around B vent Cover missing off of light switch in storage room -4303 Seal off dryer vent cavity -4304 Position heater condensate drain over drain -4105Tighten over flow compression nut Replace escuchon on sprinkler in south bedroom -4106 Everything else OK -4107 Tighten water heater overflow compression nut -4108 Install pipe from water heater overflow pan to drain -4205 Tighten water heater pan compression nut -4206 Tighten water heater pan compression nut -4207 Tighter water heater pan compression nut -4208 Tighten water heater pan compression nut 1" clearance needed around B vent -4305 Tighten water heater pan compression nut -4306 Tighten water heater pan compression nut Seal off dryer vent cavity -4307 tighten water heater pan compression nut -4308 Tighten water heater pan compression nut Inspector Comments: 06/05/2014FailTed DyeBuilding Final fire caulk dryer box's in 4303,4203,4103 and 4206Inspector Comments: 06/05/2014FailTed DyeBuilding Final 06/06/2014PassTed DyeBuilding Final -Rooms that need to have dryer boxes Fire Caulked are; 4303,4203,4103 and 4206. -Trim drywall away from B vent in room number 4203 and check 4103 Inspector Comments: Page 3 of 5 (Continued) Permit Details Permit Number: 12-00394 Mesa Falls Apts Bldg #4 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm Permit Inspection Summary 06/06/2014PassTed DyeBuilding Final All previous violations have been corrected. landscaping is scheduled to be completed on June 20th. Inspector Comments: Electrical Inspection Type 09/26/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-nail plates and staples were installed during inspection, this Approval is for electrical and fire alarm wiring both, inspected the electrical service on this inspection also. Inspector Comments: 09/26/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-2 locations, inspected the electrical services on the rough-in inspection. Inspector Comments: 11/12/2013PassBret StoddardCommercial Electrical Rough-in Approved to be energized for permanent power-2 locations, inspected the electrical services on the rough-in inspection. Inspector Comments: 04/25/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-electrical only.Inspector Comments: Fire Inspection Type 08/08/2013PassDale PickeringFire Sprinkler Rough-in 08/08/13: Bldg #4 all 24 units passed rough in. The termination in the riser room is not complete, per Chief Child. Inspector Comments: 09/23/2013PassDale PickeringFire Sprinkler Hydro 9/18 - #5 203 @1054 200 @ 1250 #4 205 @ 1054 205@1250 Bldg 3 not ready for today. 9/23 - Hydro at #205 psi - Pass Inspector Comments: 04/24/2014PassBret StoddardFire Alarm Final Inspection 06/05/2014PassDale PickeringFire Department Final Inspection 06/10/2014PassDale PickeringFire Sprinkler Final Inspection Page 4 of 5 (Continued) Permit Details Permit Number: 12-00394 Mesa Falls Apts Bldg #4 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm Permit Inspection Summary Mechanical Inspection Type 01/28/2014PassDon AllenHVAC Rough-in straiten us pipe in rm 4 3 ft gap around b vent in attic All fixed on problems Inspector Comments: 05/07/2014FailDon AllenHVAC Final Inspection 4108,4102, no fire damp. in master bathroom 4308,4307,4306,43054301,4302,4303,4304 no fire damp.in the return 4103 vent on water heater needs ran Inspector Comments: 05/14/2014PassDon AllenHVAC Final Inspection all good for the c/oInspector Comments: Plumbing Inspection Type 10/07/2013PassDon AllenPlumbing Underground Inspection 11/18/2013PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 01/13/2014PassDon AllenPlumbing Water 06/06/2014PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 5 of 5