HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00394 - Mesa Falls Apts Bldg #4Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm
Permit Details Permit Number: 12-00394
Mesa Falls Apts Bldg #4
940 S 5th W
New Multi-Family Residence
Permit Issued Date: 02/18/2014
Permit Inspection Statistics
43Total Inspections Completed:
36Total Inspections Passed:
Inspection Pass Rate: 83.72%
Permit Inspection History *Refer to Individual Inspection Report for more Details
02/24/2014PassTed DyeSheetrock/Drywall Inspection
nail patterns good
ok to tape
Inspector Comments:
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
02/24/2014PassTed DyeSheetrock/Drywall Inspection
Page 1 of 5
(Continued)
Permit Details Permit Number: 12-00394
Mesa Falls Apts Bldg #4
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm
Permit
Inspection
Summary
Building Inspection Type
06/06/2013PassQuinton OwensFoundation Inspection
6/5,QO: Middle bldg. - #4 vertical bars at ~18" oc. and 2 #4 bars cont.
(approved)
6/6,QO: Side bldgs same. (Ufer bar added to footings)
Inspector Comments:
06/20/2013PassQuinton OwensFooting Inspection
6/4 - 2 #4 bars cont.
6/20 - Ok to pour
Inspector Comments:
10/03/2013FailTed DyeFraming/Structure Inspection
4 103 Missed nailing sheeting to studs
4 201 " "
4 202 " " Btm Plate
4 204 " " " "
4 305 " "
4 306 " " " "
4 307 " "
4 106 " "
Inspector Comments:
11/29/2013PassTed DyeFraming/Structure Inspection
01/09/2014PassQuinton OwensFraming/Structure Inspection
1/9/13 QO: Framing (101-104) - 101: Firecaulk gas line at water heater, fix
laundry room wall & stud at mst. bth/closet. Firecaulk gas line by water heater
(typical). Holes for return air cut into headers. Firecaulk open gaps at fire sprnklr
crossover. 2 layers at ceiling above fireplace (1hr rated) fire caulk no complete
above elec. panel (103). *will try to finish bldg 3 on fri (1-10) for inspection.
Inspector Comments:
02/04/2014PassTed DyeFraming/Structure Inspection
4301, 302, 303, 304, 305, 306
308, 307 more insulation needed above windows. Mark orange.
Inspector Comments:
02/06/2014FailTed DyeInsulation Inspection
Insulation (bottom 2 floors) - Approved 4101, 102, 201, 202, 203, 204, 205, 206,
207, 105, 106, 107, 108.
104 &103 exhaust fan miss in bathroom and wires hanging out of ceiling.
Inspector Comments:
02/11/2014Pass Sheeting
4013 one side of sheeting not nailed, finished while there.
check exhaust fans ok.
Inspector Comments:
02/19/2014FailQuinton OwensSheetrock/Drywall Inspection
3rd and 2nd floor on South end approved for taping and Apt 108. Finish drywall
at dryer vent box for final (306,206,303). l" Clearance missing around b-vent
(305,308, 108,206,205,307, 207,208, 304). Missed screws 301 (next to door
going to laundry room, in closet facing front door, along ceiling edge in East
bdrm), 304 (on wall above stove, at vertical joint by sliding door),303 (by bthrm
sink). 1st floor not done except 108. 2nd floor North not done.
Inspector Comments:
Page 2 of 5
(Continued)
Permit Details Permit Number: 12-00394
Mesa Falls Apts Bldg #4
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm
Permit
Inspection
Summary
03/26/2014PassTed DyeInsulation Inspection
05/28/2014FailTed DyeBuilding Final
******(Typ.) All units : Tighten all compression nuts on hot water heater drain
pans****************
-4101 every thing else OK
-4102 everything else OK
-4103 Replace B vent
top strap of water heater missing
Seal off dryer vent cavity
-4104 Position condensate drain over drain
-4201 Every thing else OK
-4202 Every thing else OK
-4203 Seal off dryer vent cavity
-4204 Everything else OK
-4301 Every thing else OK
-4302 !" needed around B vent
Cover missing off of light switch in storage room
-4303 Seal off dryer vent cavity
-4304 Position heater condensate drain over drain
-4105Tighten over flow compression nut
Replace escuchon on sprinkler in south bedroom
-4106 Everything else OK
-4107 Tighten water heater overflow compression nut
-4108 Install pipe from water heater overflow pan to drain
-4205 Tighten water heater pan compression nut
-4206 Tighten water heater pan compression nut
-4207 Tighter water heater pan compression nut
-4208 Tighten water heater pan compression nut
1" clearance needed around B vent
-4305 Tighten water heater pan compression nut
-4306 Tighten water heater pan compression nut
Seal off dryer vent cavity
-4307 tighten water heater pan compression nut
-4308 Tighten water heater pan compression nut
Inspector Comments:
06/05/2014FailTed DyeBuilding Final
fire caulk dryer box's in 4303,4203,4103 and 4206Inspector Comments:
06/05/2014FailTed DyeBuilding Final
06/06/2014PassTed DyeBuilding Final
-Rooms that need to have dryer boxes Fire Caulked are; 4303,4203,4103 and
4206.
-Trim drywall away from B vent in room number 4203 and check 4103
Inspector Comments:
Page 3 of 5
(Continued)
Permit Details Permit Number: 12-00394
Mesa Falls Apts Bldg #4
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm
Permit
Inspection
Summary
06/06/2014PassTed DyeBuilding Final
All previous violations have been corrected.
landscaping is scheduled to be completed on June 20th.
Inspector Comments:
Electrical Inspection Type
09/26/2013PassBret StoddardCommercial Electrical Rough-in
Approved for cover-nail plates and staples were installed during inspection, this
Approval is for electrical and fire alarm wiring both, inspected the electrical
service on this inspection also.
Inspector Comments:
09/26/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-2 locations, inspected the
electrical services on the rough-in inspection.
Inspector Comments:
11/12/2013PassBret StoddardCommercial Electrical Rough-in
Approved to be energized for permanent power-2 locations, inspected the
electrical services on the rough-in inspection.
Inspector Comments:
04/25/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O.-electrical only.Inspector Comments:
Fire Inspection Type
08/08/2013PassDale PickeringFire Sprinkler Rough-in
08/08/13: Bldg #4 all 24 units passed rough in. The termination in the riser room
is not complete, per Chief Child.
Inspector Comments:
09/23/2013PassDale PickeringFire Sprinkler Hydro
9/18 - #5 203 @1054 200 @ 1250
#4 205 @ 1054 205@1250
Bldg 3 not ready for today.
9/23 - Hydro at #205 psi - Pass
Inspector Comments:
04/24/2014PassBret StoddardFire Alarm Final Inspection
06/05/2014PassDale PickeringFire Department Final Inspection
06/10/2014PassDale PickeringFire Sprinkler Final Inspection
Page 4 of 5
(Continued)
Permit Details Permit Number: 12-00394
Mesa Falls Apts Bldg #4
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:14 pm
Permit
Inspection
Summary
Mechanical Inspection Type
01/28/2014PassDon AllenHVAC Rough-in
straiten us pipe in rm 4
3 ft gap around b vent in attic
All fixed on problems
Inspector Comments:
05/07/2014FailDon AllenHVAC Final Inspection
4108,4102, no fire damp. in master bathroom
4308,4307,4306,43054301,4302,4303,4304 no fire damp.in the return
4103 vent on water heater needs ran
Inspector Comments:
05/14/2014PassDon AllenHVAC Final Inspection
all good for the c/oInspector Comments:
Plumbing Inspection Type
10/07/2013PassDon AllenPlumbing Underground Inspection
11/18/2013PassDon AllenPlumbing Rough-in
All good to cover the rough inInspector Comments:
01/13/2014PassDon AllenPlumbing Water
06/06/2014PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
Page 5 of 5