Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00392 - Mesa Falls Apts Bldg #2Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/18/2020 3:10 pm Permit Details Permit Number: 12-00392 Mesa Falls Apts Bldg #2 940 S 5th W New Multi-Family Residence Permit Issued Date: 02/27/2014 Permit Inspection Statistics 26Total Inspections Completed: 21Total Inspections Passed: Inspection Pass Rate: 80.77% Permit Inspection History *Refer to Individual Inspection Report for more Details 01/02/2014PassDale PickeringFire Underground Inspection Building Inspection Type 04/22/2013PassQuinton OwensFoundation Inspection 2 #4 horizontal rebar. Vertical rebar should be 18" oc. Vertical dowels in footing occasionally at 19 - 21" oc. Inspector Comments: 05/20/2013PassQuinton OwensFooting Inspection 4/19, 2 - #4 rebar cont. and supported. Ufer installed in footing in each side building. 5/10, QO: Interior footings ok to pour 2 #4 rebar supported on chairs. Inspector Comments: 09/12/2013Fail Sheetrock/Drywall Inspection rm 207 & 208 - fire caulk above tub. 2105 2206 split insulation to go behind wires 205 fire caulking 2106 repair or replace broken stud, fire blocking missed. 207 concealed space missed blockig Inspector Comments: 09/12/2013Fail Sheetrock/Drywall Inspection Insulation 2301 302 303 & 304 covered before inspected 2201 concealed space/ fire caulk below washer box 2203 fire caulking 2202 fire caulking 2204 fire caulking Inspector Comments: 09/12/2013Pass Sheetrock/Drywall Inspection 09/20/2013FailQuinton OwensSheetrock/Drywall Inspection sheetrock screw - 1st floor bldg #2 - 1st floor ok to tape except fire rated boxes for sprinkler pipe (not done). (101-flex duct not allowed as penetrating item). Inspector Comments: 11/01/2013Pass Sidewalk Inspection 9/4,QO: 3rd floor ok to insulate.Inspector Comments: 9/17,QO: Interior shear wall panels. Done.Inspector Comments: 12/26/2013PassQuinton OwensFraming/Structure Inspection 9/24,QO: fire caulk reinspect in breezways and fireboxes for sprinkler pipe crossing corridor. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00392 Mesa Falls Apts Bldg #2 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:10 pm Permit Inspection Summary 12/30/2013Pass Building Final OK 201 102 103 104 201 202 204 301 302 303 304 105 106 107 108 205 206 207 208 305 307 308 - ok strap on water heater lose at 306 - fixed while i was there 203 - gas smell. fixed as well. Inspector Comments: Electrical Inspection Type 08/21/2013Pass Commercial Electrical Rough-in Approved for cover in all 24 units of building #2-also inspected the electrical service on this inspection, also for fire alarm wiring. Inspector Comments: 08/21/2013Pass COM & MFR Electrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection. Inspector Comments: 12/20/2013Pass COM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O. building #2 only.Inspector Comments: Fire Inspection Type 01/02/2013PassDale PickeringFire Sprinkler Final Inspection 08/21/2013Pass Fire Alarm Rough-in Approved for cover in all 24 units of building #2-also inspected the electrical service on this inspection, also for fire alarm wiring. Inspector Comments: 09/23/2013PassDale PickeringFire Sprinkler Hydro Bldg #2; Hydro at #200 psi - PassInspector Comments: 12/19/2013Pass Fire Alarm Final Inspection Approved for a final and C.O.-fire alarm only, witnessed all signalling and initiating device operation, 24 hour/5minute test from 3:30PM 12/18 to 3:45PM 12/19 for AC restored, flow switch(36 seconds) and tamper switches(2) operational-witnessed, panel had 2 hour delay for AC loss because of dip switch #6 on panel as per Gary with Omni, report in file. Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00392 Mesa Falls Apts Bldg #2 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:10 pm Permit Inspection Summary Mechanical Inspection Type 9/4,QO: 3rd floor approved except b-vents not done. (reinspect with insulation)Inspector Comments: 9/12,QO: 2nd floor approved (fir out wall at b-vent in 203 with 1" clearance to drywall). Inspector Comments: 9/17,QO: 1st floor approved (Firecaulking needed all around dryer vents for final-see 203,103, and 106). Finish "fire boxes" with dampers where sprinkler lines crosses breezeway. Inspector Comments: 09/23/2013PassQuinton OwensHVAC Rough-in 9/23,QO:Dampers at sprinkler pipe thru brzwy done.Inspector Comments: 12/27/2013FailQuinton OwensHVAC Final Inspection Firecaulk around B-vents on 1st floor at gaps between metal shield and drywall. Firecaulk, not fireblk, at living room dampers (101,202,207,107). Gas odor near regulator or connections in 103, 306, 207(csst). Vent limiter missing on regulator in 307. Fix connection between vent connector and B-vent at water heater. Inspector Comments: 12/31/2013PassQuinton OwensHVAC Final Inspection 12/30: 108 still has gas odor by CSST connection by furnace.(green wires are separated on top of furnace. OK?) 12/30: Don Allen approved 108 fix. Inspector Comments: Plumbing Inspection Type 05/16/2013Pass Plumbing Underground Inspection all good to cover the ground workInspector Comments: 10/25/2013Pass Plumbing Water 10/25/2013Pass Plumbing Sewer 10/25/2013Pass Plumbing Rough-in 12/24/2013Fail Plumbing Final Inspection need duply on toilet in the master bath 1stfloop north west apt t&p droops dishwashers need hooked up Inspector Comments: 01/02/2014PassDon AllenPlumbing Final Inspection Don stated that he went back and reinspected final.Inspector Comments: Page 3 of 3