HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00395 - Mesa Falls Apts Bldg #5Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm
Permit Details Permit Number: 12-00395
Mesa Falls Apts Bldg #5
940 S 5th W
New Multi-Family Residence
Permit Issued Date: 02/18/2014
Permit Inspection Statistics
23Total Inspections Completed:
18Total Inspections Passed:
Inspection Pass Rate: 78.26%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/15/2013PassQuinton OwensFoundation Inspection
5/14,QO: Middle section- #4grd60 (2) cont. horiz & vert at 18" oc.
5/15: Side buildings same, full length #4 bar for ufer ground installed in each
side bldg.
Inspector Comments:
06/05/2013PassQuinton OwensFooting Inspection
5/13, QO: 2 #4rebar (grd 60) supported for clearance. (interior ftgs later)
6/5,QO: 2 #4 rebar in ftgs
Inspector Comments:
10/04/2013FailTed DyeInsulation Inspection
Sheetrock passthrough - Door not hung
5 305 stud missing as you enter door on left
5 306 Framing supporting water shutoff missing
5 307 Fire Bloacking underneath panel-Ok, Thermistat fire caulk missing
5 308 Insulation missing in corner by waterheater, thermostate wire fire caulking
5 205 Thermistat wire fire caulk, insulation shield to go to under deck
5 201 Remove Fire Block from between insulation shield and B vent
5 202 Fire Block wires @ CLM plate @ Elect panel ok, Fire alarm wire @ btm
plate
5 203 extend insulation shield to above deck
5 207 Insulation shield to go to under deck
Fire Block gas line btm plate
Fire caulk thermistat
Fire Block main drain line
Fire Block fire wire @ btm plate
5 208 Fire Block wires hole under panel box ok
Fire Block wire hole north west wall ok
Gas line btm plate ok
Missing insulation shield for B vent
Fire wire fire caulk @ btm plate
5 204 Fire caulk wires under elect. panel
5 304 Ok
5 302 OK
5 301 insulate cracks between studes, Bedroom N. E
5 304 Missing patio door & Insulation
5 305-6-7 & 8 not finished
Inspector Comments:
Page 1 of 4
(Continued)
Permit Details Permit Number: 12-00395
Mesa Falls Apts Bldg #5
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm
Permit
Inspection
Summary
10/07/2013PassTed DyeSheetrock/Drywall Inspection
Sheetrock Screw - 5301 Ok to tape
5302 - ok to tape
5303 - fire caulk dryer vent
5304 - cut around shield on B vent, Ok to tape.
5305 - cut around shield on B vent, OK to tape.
5307 - Drywall in bedroom on separation wall to B type X, cut around "B" vent
shield. All but 5307 approved.
Inspector Comments:
10/08/2013FailTed DyeInsulation Inspection
3rd Floor Sheet rock/insulation
5 306 Ok to tape
5 307 Ok to tape
5 308 Ok to tape
2nd Floor
Insulation 5 205 Fire caulk, gas line by B vent
5 206 Gas line by B vent fire caulk
5 207 Fire Block gas line near front door/ fire caulk emty hole @ separation of
bedroom wall/ fire caulk dryer vent/ fire caulk dryer vent near B vent
5 208 Fire caulk dryer vent/ drywall in cavity @ tub @ separation wall/ fire caulk
gas line by tub
5 204 fire caulk hole, btm plate, sub wall @ kitchen
5 203 Box out dryer vent & fire caulk
5 202 Fire caulk hole, stub wall kitchen area/ fire caulk thermastat wire/ fire caulk
gas line by tub/ shettrock & insulate by pass
5 201 Stude near B vent needs to be nailed at top/ drywall needed in cavity by
tub @ separation wall/ insulation by bad stud in ceiling by sprinkler need
insulation. Wires to ouside wall between bedrooms needs fire caulked also
between bedroom & living room.
Inspector Comments:
7/16/13 - sheer walls areas missed nailing marked in green DA
10/24/13 - interior sheer wall
1st floor sheeting was all visible.OK -2nd floor
and 3rd floor was covered with drywall.Looked at windows and electrical boxed
and under sheetrock at floor level to verify that their was sheer wall material
(OSB).found at locations required
Inspector Comments:
10/24/2013PassTed DyeFraming/Structure Inspection
10/15/13: 1st level east side ready. Other units not readyInspector Comments:
10/29/2013PassTed DyeSheetrock/Drywall Inspection
Sheetrock, Screw - 5101-5104 OK to tape.
5106 Ok to tape.
Inspector Comments:
Page 2 of 4
(Continued)
Permit Details Permit Number: 12-00395
Mesa Falls Apts Bldg #5
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm
Permit
Inspection
Summary
10/30/2013PassTed DyeInsulation Inspection
10/10,QO: 2nd floor ok to drywall.
windows and doors not insalled will inspect at drywall inspection
10-24-13: 1st floor insulation 5106 fire calulk neeeded marked with orange
paint.
5105 Stud missing in wall
ALL but above approved for cover.
All of building to cover
Inspector Comments:
11/01/2013PassTed DyeSheetrock/Drywall Inspection
Sheetrock Nailing (West Main Level) - 5105 OK to tape.
5107 OK to tape
5108 OK to tape
Bldg #5 drywall complete.
Inspector Comments:
03/05/2014FailTed DyeBuilding Final
5101 passed
5102 passed
5103 passed
5104 passed
5201 passed
5202 passed
5203 drywall needed on side of dryer vent box
5204 passed
5301 passed
5302 passed
5303 passed
5304 passed
5105 not competed
5106 drywall sides of dryer vent box
5107 1 inch clearance needed around B vent
5108 passed
5205 dishwasher not installed
5206 dishwasher not installed
5207 not compete water damage
5208 dishwasher not installed
5305 dishwasher not installed
5306 dishwasher not installed
5307 dishwasher not installed
5308 dishwasher not installed
Inspector Comments:
03/10/2014FailTed DyeBuilding Final
all apt. done except 5105Inspector Comments:
03/26/2014PassTed DyeBuilding Final
apt. 207,208 and 305 have their water damage repaired
all other apts have been inspected and approved
Inspector Comments:
Page 3 of 4
(Continued)
Permit Details Permit Number: 12-00395
Mesa Falls Apts Bldg #5
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm
Permit
Inspection
Summary
Electrical Inspection Type
02/18/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Fire Inspection Type
09/23/2013PassDale PickeringFire Sprinkler Hydro
Hydro at #203 psi - PassInspector Comments:
03/11/2014PassBret StoddardFire Alarm Final Inspection
04/24/2014PassDale PickeringFire Department Final Inspection
04/24/2014PassDale PickeringFire Sprinkler Final Inspection
Mechanical Inspection Type
10/15/2013PassDon AllenHVAC Rough-in
need 1 inch clearance around water heater vent
need to replace around on water heater
support gas line in breeze way
Inspector Comments:
03/03/2014PassDon AllenHVAC Final Inspection
all good for c/oInspector Comments:
Plumbing Inspection Type
05/31/2013Pass Plumbing Underground Inspection
10/11/2013PassDon AllenPlumbing Rough-in
02/28/2014FailDon AllenPlumbing Final Inspection
05/19/2015PassDon AllenPlumbing Final Inspection
gppd for the c/oInspector Comments:
Page 4 of 4