Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00395 - Mesa Falls Apts Bldg #5Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm Permit Details Permit Number: 12-00395 Mesa Falls Apts Bldg #5 940 S 5th W New Multi-Family Residence Permit Issued Date: 02/18/2014 Permit Inspection Statistics 23Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 78.26% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/15/2013PassQuinton OwensFoundation Inspection 5/14,QO: Middle section- #4grd60 (2) cont. horiz & vert at 18" oc. 5/15: Side buildings same, full length #4 bar for ufer ground installed in each side bldg. Inspector Comments: 06/05/2013PassQuinton OwensFooting Inspection 5/13, QO: 2 #4rebar (grd 60) supported for clearance. (interior ftgs later) 6/5,QO: 2 #4 rebar in ftgs Inspector Comments: 10/04/2013FailTed DyeInsulation Inspection Sheetrock passthrough - Door not hung 5 305 stud missing as you enter door on left 5 306 Framing supporting water shutoff missing 5 307 Fire Bloacking underneath panel-Ok, Thermistat fire caulk missing 5 308 Insulation missing in corner by waterheater, thermostate wire fire caulking 5 205 Thermistat wire fire caulk, insulation shield to go to under deck 5 201 Remove Fire Block from between insulation shield and B vent 5 202 Fire Block wires @ CLM plate @ Elect panel ok, Fire alarm wire @ btm plate 5 203 extend insulation shield to above deck 5 207 Insulation shield to go to under deck Fire Block gas line btm plate Fire caulk thermistat Fire Block main drain line Fire Block fire wire @ btm plate 5 208 Fire Block wires hole under panel box ok Fire Block wire hole north west wall ok Gas line btm plate ok Missing insulation shield for B vent Fire wire fire caulk @ btm plate 5 204 Fire caulk wires under elect. panel 5 304 Ok 5 302 OK 5 301 insulate cracks between studes, Bedroom N. E 5 304 Missing patio door & Insulation 5 305-6-7 & 8 not finished Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 12-00395 Mesa Falls Apts Bldg #5 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm Permit Inspection Summary 10/07/2013PassTed DyeSheetrock/Drywall Inspection Sheetrock Screw - 5301 Ok to tape 5302 - ok to tape 5303 - fire caulk dryer vent 5304 - cut around shield on B vent, Ok to tape. 5305 - cut around shield on B vent, OK to tape. 5307 - Drywall in bedroom on separation wall to B type X, cut around "B" vent shield. All but 5307 approved. Inspector Comments: 10/08/2013FailTed DyeInsulation Inspection 3rd Floor Sheet rock/insulation 5 306 Ok to tape 5 307 Ok to tape 5 308 Ok to tape 2nd Floor Insulation 5 205 Fire caulk, gas line by B vent 5 206 Gas line by B vent fire caulk 5 207 Fire Block gas line near front door/ fire caulk emty hole @ separation of bedroom wall/ fire caulk dryer vent/ fire caulk dryer vent near B vent 5 208 Fire caulk dryer vent/ drywall in cavity @ tub @ separation wall/ fire caulk gas line by tub 5 204 fire caulk hole, btm plate, sub wall @ kitchen 5 203 Box out dryer vent & fire caulk 5 202 Fire caulk hole, stub wall kitchen area/ fire caulk thermastat wire/ fire caulk gas line by tub/ shettrock & insulate by pass 5 201 Stude near B vent needs to be nailed at top/ drywall needed in cavity by tub @ separation wall/ insulation by bad stud in ceiling by sprinkler need insulation. Wires to ouside wall between bedrooms needs fire caulked also between bedroom & living room. Inspector Comments: 7/16/13 - sheer walls areas missed nailing marked in green DA 10/24/13 - interior sheer wall 1st floor sheeting was all visible.OK -2nd floor and 3rd floor was covered with drywall.Looked at windows and electrical boxed and under sheetrock at floor level to verify that their was sheer wall material (OSB).found at locations required Inspector Comments: 10/24/2013PassTed DyeFraming/Structure Inspection 10/15/13: 1st level east side ready. Other units not readyInspector Comments: 10/29/2013PassTed DyeSheetrock/Drywall Inspection Sheetrock, Screw - 5101-5104 OK to tape. 5106 Ok to tape. Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 12-00395 Mesa Falls Apts Bldg #5 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm Permit Inspection Summary 10/30/2013PassTed DyeInsulation Inspection 10/10,QO: 2nd floor ok to drywall. windows and doors not insalled will inspect at drywall inspection 10-24-13: 1st floor insulation 5106 fire calulk neeeded marked with orange paint. 5105 Stud missing in wall ALL but above approved for cover. All of building to cover Inspector Comments: 11/01/2013PassTed DyeSheetrock/Drywall Inspection Sheetrock Nailing (West Main Level) - 5105 OK to tape. 5107 OK to tape 5108 OK to tape Bldg #5 drywall complete. Inspector Comments: 03/05/2014FailTed DyeBuilding Final 5101 passed 5102 passed 5103 passed 5104 passed 5201 passed 5202 passed 5203 drywall needed on side of dryer vent box 5204 passed 5301 passed 5302 passed 5303 passed 5304 passed 5105 not competed 5106 drywall sides of dryer vent box 5107 1 inch clearance needed around B vent 5108 passed 5205 dishwasher not installed 5206 dishwasher not installed 5207 not compete water damage 5208 dishwasher not installed 5305 dishwasher not installed 5306 dishwasher not installed 5307 dishwasher not installed 5308 dishwasher not installed Inspector Comments: 03/10/2014FailTed DyeBuilding Final all apt. done except 5105Inspector Comments: 03/26/2014PassTed DyeBuilding Final apt. 207,208 and 305 have their water damage repaired all other apts have been inspected and approved Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 12-00395 Mesa Falls Apts Bldg #5 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/18/2020 3:08 pm Permit Inspection Summary Electrical Inspection Type 02/18/2014PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Fire Inspection Type 09/23/2013PassDale PickeringFire Sprinkler Hydro Hydro at #203 psi - PassInspector Comments: 03/11/2014PassBret StoddardFire Alarm Final Inspection 04/24/2014PassDale PickeringFire Department Final Inspection 04/24/2014PassDale PickeringFire Sprinkler Final Inspection Mechanical Inspection Type 10/15/2013PassDon AllenHVAC Rough-in need 1 inch clearance around water heater vent need to replace around on water heater support gas line in breeze way Inspector Comments: 03/03/2014PassDon AllenHVAC Final Inspection all good for c/oInspector Comments: Plumbing Inspection Type 05/31/2013Pass Plumbing Underground Inspection 10/11/2013PassDon AllenPlumbing Rough-in 02/28/2014FailDon AllenPlumbing Final Inspection 05/19/2015PassDon AllenPlumbing Final Inspection gppd for the c/oInspector Comments: Page 4 of 4