HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00407 - Mesa Falls Apts Bldg #10Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/14/2020 10:41 am Permit Details Permit Number: 12-00407 Mesa Falls Apts Bldg #10 940 S 5th W New Multi-Family Residence Permit Issued Date: 09/04/2014 Permit Inspection Statistics 37Total Inspections Completed: 25Total Inspections Passed: Inspection Pass Rate: 67.57% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 09/05/2014PassTed DyeResidential Footing Inspection 09/08/2014PassTed DyeFoundation Inspection 09/09/2014PassTed DyeFoundation Inspection 09/25/2014PassTed DyeCommercial Footing Inspection 01/14/2015FailTed DyeSheeting -Units 10101, 103, 201, 204, 205, and 303 have sheeting that has missed being stapled to studs. -Units 10201, 206, 207, 208, 308 and 302 have straps that have nails missing studs. Inspector Comments: 01/30/2015PassTed DyeSheeting 02/17/2015Fail Commercial Framing/Structure Inspection 02/17/2015FailTed DyeCommercial Framing/Structure Inspection Unit 10201 needs sealed off at the ceiling level. Units 101-108 the framing and fire caulking is approved. Units 202- 208 the framing and fire caulking is approved. Units 301-308 the framing and fire caulking is approved. Inspector Comments: 02/18/2015PassTed DyeCommercial Insulation Inspection 02/19/2015PassTed DyeCommercial Insulation Inspection 02/23/2015FailQuinton OwensCommercial Insulation Inspection Fix insulation behind electrical panel (103) and fireblock dryer vent penetration (105). OTHER MAIN FLOOR UNITS APPROVED. Note: Be sure not to over compress insulation in order to achieve required R-values and batts are required to have R-value labeling facing inside for inspection. Inspector Comments: 02/24/2015FailTed DyeCommercial Sheetrock/Drywall Inspection see picturesInspector Comments: 02/24/2015Fail Commercial Sheetrock/Drywall Inspection 02/24/2015FailTed DyeCommercial Insulation Inspection Page 1 of 3 (Continued) Permit Details Permit Number: 12-00407 Mesa Falls Apts Bldg #10 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 10:41 am Permit Inspection Summary 02/24/2015Pass Commercial Framing/Structure Inspection checked with insulation inspectionInspector Comments: 02/25/2015PassTed DyeCommercial Insulation Inspection All of the second floor is approved for tape and textureInspector Comments: 02/27/2015PassTed DyeCommercial Sheetrock/Drywall Inspection All of the 3rd floor is approved to tape and textureInspector Comments: 03/02/2015PassTed DyeCommercial Sheetrock/Drywall Inspection 06/01/2015FailTed DyeResidential Building Final 10101 reconnect B vent 203 Firecaulk around gas pipe through the ceiling in the furnace room 108 Seal bottom of tub Units that passed are; 102, 103, 104, 105, 106, 107, 201, 202, 204, 205, 206, 207, 208, 301, 302, 303, 304, 305, 306, 307 and 308. Inspector Comments: 06/03/2015FailTed DyeResidential Building Final landscapiing to be complete before C.O. can be issued for occupancyInspector Comments: 07/08/2015PassQuinton OwensResidential Building Final Landscaping done. HC parking signs installed (HC symbol not painted on stalls yet) Inspector Comments: Electrical Inspection Type 02/17/2015PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 02/18/2015PassBret StoddardCOM & MFR Electrical Service Inspection 02/18/2015PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in 05/14/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Fire Inspection Type 02/19/2015PassDale PickeringFire Sprinkler Rough-in 05/07/2015PassDale PickeringFire Sprinkler Hydro 06/02/2015PassBret StoddardFire Alarm Final Inspection 06/04/2015PassDale PickeringFire Sprinkler Final Inspection Mechanical Inspection Type 02/12/2015FailDon AllenHVAC Rough-in 02/13/2015FailDon AllenHVAC Rough-in 04/29/2015PassDon AllenHVAC Rough-in 05/14/2015PassDon AllenHVAC Final Inspection GOOD FOR THE C/OInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00407 Mesa Falls Apts Bldg #10 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 10:41 am Permit Inspection Summary Plumbing Inspection Type 09/22/2014PassDon AllenPlumbing Underground Inspection All good to cover the ground workInspector Comments: 01/30/2015PassDon AllenPlumbing Rough-in 06/01/2015PassDon AllenPlumbing Final Inspection GOOD FOR THE C/OInspector Comments: Page 3 of 3