HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00405 - Mesa Falls Apts Bldg #8Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/14/2020 10:21 am Permit Details Permit Number: 12-00405 Mesa Falls Apts Bldg #8 940 S 5th W New Multi-Family Residence Permit Issued Date: 09/24/2014 Permit Inspection Statistics 39Total Inspections Completed: 25Total Inspections Passed: Inspection Pass Rate: 64.10% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 09/25/2014PassTed DyeCommercial Footing Inspection 09/26/2014PassQuinton OwensFoundation Inspection Foundation for center section of building. Finish bracing forms on west side with required clearance around rebar. Inspector Comments: 09/29/2014PassTed DyeFoundation Inspection 10/30/2014PassTed DyeCommercial Footing Inspection Shovel footingsInspector Comments: 03/03/2015FailTed DyeSheeting First Floor sheeting inspection; Those areas that sheeting missed being nailed to studs have been marked with green paint. Second and the third floors was not accessible. Call for reinspect when ready and accessible. Inspector Comments: 03/06/2015Fail Sheeting Those spots that the sheeting missed being nailed to the stud, or where the hold down nails missed solid backing, are marked with green paint. Call for re-inspection of all three floors, when those items have been corrected. Inspector Comments: 03/27/2015FailTed DyeSheeting There was two locations that missed being nailed to studs. Both are on the 2nd level in the breeze ways. Marked with green paint. Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 12-00405 Mesa Falls Apts Bldg #8 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 10:21 am Permit Inspection Summary 04/07/2015FailTed DyeCommercial Framing/Structure Inspection Units that pass are: 101, 102, 103, 204, 205, 206, 208, 301, 302, 303, 304, 305, 306, 307and 308. Unit 104; Fire block both bath room exhaust vents at the rim joist.OK Unit 105:Drywall above B vent.OK -107, Fire block both dryer vents on outside wall. didn't get them totally sealed.OK -201 Fire caulk water line in separation wall.OK2 -202 Seal the consealed area at the top plate area.OK -203Fire caulk emty hole in top plate in wall next to the entrance door/ also in same wall fire block around sprinkler line that goes through the exterior wall.OK -207 Fire caulk empty hole in top plate in wall next to the entrance door, /and the fire sprinkler line going through the exterior wall.OK Fire caulk emty hole in top plate in wall by entrance door. -207 Fire caulk empy hole in top plate in wall by entrance door. Inspector Comments: 04/07/2015PassTed DyeSheeting 04/08/2015PassTed DyeCommercial Framing/Structure Inspection 04/08/2015PassTed DyeCommercial Insulation Inspection 04/09/2015PassTed DyeCommercial Insulation Inspection Second floor passed offInspector Comments: 04/13/2015PassTed DyeCommercial Sheetrock/Drywall Inspection Units 301, 302, 303, 304, 305, 307 and 308 Unit 306 was not complete. Inspector Comments: 04/13/2015PassTed DyeCommercial Insulation Inspection 1st and 2nd floor insulation inspectionInspector Comments: 04/15/2015PassTed DyeCommercial Sheetrock/Drywall Inspection Units passed are; Level 3 Unit 8306 completes level 3 Level 2: Units 8201, 202 and 205. .........All other units on level 2 have not been completed Inspector Comments: 04/17/2015FailTed DyeCommercial Sheetrock/Drywall Inspection 04/20/2015PassTed DyeCommercial Sheetrock/Drywall Inspection Units 201-208 corrections made. Units 101-108 pass. Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 12-00405 Mesa Falls Apts Bldg #8 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 10:21 am Permit Inspection Summary 07/14/2015FailTed DyeCommercial Sheetrock/Drywall Inspection unit 8201 needs to have drywall removed on the top, inside edge, around B vent. all other units passed Inspector Comments: 07/16/2015PassTed DyeCommercial Sheetrock/Drywall Inspection 8201 B vent clearance completed.Inspector Comments: 07/29/2015FailTed DyeResidential Building Final Fire caulk around ducts in furnuss room, All of first floor and gas pipes on 3rd floor. Inspector Comments: exterior landscaping left thus the fail.Inspector Comments: 08/12/2015FailTed DyeResidential Building Final exterior landscaping left thus the fail.Inspector Comments: 08/17/2015PassTed DyeResidential Building Final Electrical Inspection Type 04/06/2015PassBret StoddardResidential Electrical Service Inspection 04/06/2015PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 07/15/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 03/16/2016N/APorter WilkinsCommercial Electrical Rough-in 03/16/2016N/APorter WilkinsResidential Electrical Service Inspection Fire Inspection Type 01/29/2015PassDale PickeringFire Sprinkler Rough-in 05/14/2015FailDale PickeringFire Sprinkler Hydro 05/20/2015PassDale PickeringFire Sprinkler Hydro 07/21/2015PassBret StoddardFire Alarm Final Inspection Mechanical Inspection Type 04/06/2015PassDon AllenHVAC Rough-in GOOD TO COVERTHE MECHANICAL ROUGH INInspector Comments: 07/17/2015FailDon AllenHVAC Final Inspection missing drain lines on the furnaces.Inspector Comments: 07/24/2015FailDon AllenHVAC Final Inspection APT. 8208 IS MISSING THE TRAP IN THE DRAINLINE OFF THE FURNACE.Inspector Comments: 07/28/2015PassDon AllenHVAC Final Inspection GOOD FOR THE C/OInspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 12-00405 Mesa Falls Apts Bldg #8 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 10:21 am Permit Inspection Summary Plumbing Inspection Type 10/14/2014PassDon AllenPlumbing Underground Inspection 03/30/2015PassDon AllenPlumbing Rough-in All good to cover plumbing rough in.Inspector Comments: 07/28/2015PassDon AllenPlumbing Final Inspection GOOD FOR THE C/OInspector Comments: 03/16/2016N/APorter WilkinsPlumbing Rough-in Page 4 of 4