Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00402 - Mesa Falls Apts Bldg #13Permit Inspection Summary Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am Permit Details Permit Number: 12-00402 Mesa Falls Apts Bldg #13 940 S 5th W New Multi-Family Residence Permit Issued Date: 08/04/2014 Permit Inspection Statistics 30Total Inspections Completed: 22Total Inspections Passed: Inspection Pass Rate: 73.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 07/31/2014PassTed DyeResidential Footing Inspection 08/01/2014PassQuinton OwensFoundation Inspection 08/05/2014PassTed DyeFoundation Inspection 08/08/2014PassTed DyeFoundation Inspection 12+ inches of granular fillInspector Comments: 08/25/2014PassTed DyeResidential Footing Inspection some sheeting not nailed to studs on 2nd and 3rd floorsInspector Comments: 10/14/2014FailTed DyeSheeting studs marked with green paintInspector Comments: 10/23/2014FailTed DyeCommercial Framing/Structure Inspection -Drywall concealed area's in most units. (typ. in all units) - Fire caulk waterlines above tub in prerock area's. -Fire block exterior walls. (call for inspection before insulating.) Inspector Comments: 11/14/2014FailTed DyeCommercial Framing/Structure Inspection 11/14/2014PassTed DyeCommercial Insulation Inspection 11/17/2014FailTed DyeCommercial Framing/Structure Inspection 11/17/2014FailTed DyeCommercial Insulation Inspection 11/18/2014PassTed DyeCommercial Framing/Structure Inspection Sheeting between 101 and 103 has been nailed. passedInspector Comments: 11/18/2014PassTed DyeCommercial Insulation Inspection 11/25/2014PassTed DyeSheeting 11/25/2014PassTed DyeCommercial Sheetrock/Drywall Inspection Page 1 of 3 (Continued) Permit Details Permit Number: 12-00402 Mesa Falls Apts Bldg #13 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am Permit Inspection Summary 03/11/2015FailTed DyeCommercial Building Final 13201: Furnuss room, Repair drywall on ceiling and fire caulk. Caulk around vent pipe and thermastate wire. 204: Furnuass room, Repair drywall on ceiling and fire caulk. 301: Smoke/C.O. detector needed outside of East bedroom. Furnuss room, Fire caulk around gas pipe. 302: Furnuss room, Fire caulk around gas and thermostat. Southwest bedroom, Gap around fire sprinkler head. 303: Furnuss room; fire caulk gas pipe at the ceiling. 304: Furnuss room; fire caulk gas pipe at the ceiling. 105: Utility room; remove paper of sheetrock on the back side of the drywall at the B vent. 106: Utility room; remove paper of sheetrock on the back side of the drywall at the B vent. 108: Utility room; 1" is needed around the B vent. Fire caulk around the drain pipe in bathroom. Furnuss room: Fire caulk around the thermostat wire. 205 Utility; 1" needed aroun the B vent. 206 Gas Smell in unit Fire caulk around vanity drain. 1" is needed around the B vent. 207 1" is needed around the B vent. Extend drain pipe from water heater drain pan to the floor drain. NOTE...... CHECK ALL WATER HEATER PANS. 208 Smoke/C.O. detector needed outside of Southwest bedroom NOTE....Check all units with bedrooms on oppisite sides. 305: Drain pipe from water heater overflow pan neededs to extend to the floor drain. Furnuss room; Fire caulk around gas pipe in ceiling. 306:Furnuss room; Fire caulk around gas pipe in ceiling. 307:Utility room; Extend drain line from water heater overflow pan to the floor drain. 308:Utility room; Extend drain line from water heater overflow pan to the floor drain. Fire caulk around the Southeast bathroom vanity drain line. Inspector Comments: 03/17/2015FailTed DyeCommercial Building Final Temp. C.O. may be issued till the landscaping is completed.Inspector Comments: 06/12/2015PassTed DyeCommercial Building Final Electrical Inspection Type 11/03/2014PassBret StoddardCOM & MFR Electrical Service Inspection 11/10/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 02/24/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 12-00402 Mesa Falls Apts Bldg #13 940 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am Permit Inspection Summary Fire Inspection Type 01/13/2015PassDale PickeringFire Sprinkler Hydro 02/09/2015FailDale PickeringFire Sprinkler Final Inspection 02/26/2015PassBret StoddardFire Alarm Final Inspection 03/10/2015PassBret StoddardFire Sprinkler Final Inspection Mechanical Inspection Type 11/06/2014PassDon AllenHVAC Rough-in All good to cover the mechanical rough in Gas presser held at 60 lb on 25 of the units Inspector Comments: 02/19/2015PassDon AllenHVAC Final Inspection mech is good for the c/oInspector Comments: Plumbing Inspection Type 08/18/2014PassDon AllenPlumbing Underground Inspection Good to cover the under groundInspector Comments: 10/30/2014PassDon AllenPlumbing Rough-in All good to cover rough inInspector Comments: 03/04/2015PassPLL ADMINPlumbing Final Inspection **Completed by Brian Hill**Inspector Comments: Page 3 of 3