HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00402 - Mesa Falls Apts Bldg #13Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am
Permit Details Permit Number: 12-00402
Mesa Falls Apts Bldg #13
940 S 5th W
New Multi-Family Residence
Permit Issued Date: 08/04/2014
Permit Inspection Statistics
30Total Inspections Completed:
22Total Inspections Passed:
Inspection Pass Rate: 73.33%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
07/31/2014PassTed DyeResidential Footing Inspection
08/01/2014PassQuinton OwensFoundation Inspection
08/05/2014PassTed DyeFoundation Inspection
08/08/2014PassTed DyeFoundation Inspection
12+ inches of granular fillInspector Comments:
08/25/2014PassTed DyeResidential Footing Inspection
some sheeting not nailed to studs on 2nd and 3rd floorsInspector Comments:
10/14/2014FailTed DyeSheeting
studs marked with green paintInspector Comments:
10/23/2014FailTed DyeCommercial Framing/Structure Inspection
-Drywall concealed area's in most units. (typ. in all units)
- Fire caulk waterlines above tub in prerock area's.
-Fire block exterior walls. (call for inspection before insulating.)
Inspector Comments:
11/14/2014FailTed DyeCommercial Framing/Structure Inspection
11/14/2014PassTed DyeCommercial Insulation Inspection
11/17/2014FailTed DyeCommercial Framing/Structure Inspection
11/17/2014FailTed DyeCommercial Insulation Inspection
11/18/2014PassTed DyeCommercial Framing/Structure Inspection
Sheeting between 101 and 103 has been nailed. passedInspector Comments:
11/18/2014PassTed DyeCommercial Insulation Inspection
11/25/2014PassTed DyeSheeting
11/25/2014PassTed DyeCommercial Sheetrock/Drywall Inspection
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00402
Mesa Falls Apts Bldg #13
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am
Permit
Inspection
Summary
03/11/2015FailTed DyeCommercial Building Final
13201: Furnuss room, Repair drywall on ceiling and fire caulk.
Caulk around vent pipe and thermastate wire.
204: Furnuass room, Repair drywall on ceiling and fire caulk.
301: Smoke/C.O. detector needed outside of East bedroom.
Furnuss room, Fire caulk around gas pipe.
302: Furnuss room, Fire caulk around gas and thermostat.
Southwest bedroom, Gap around fire sprinkler head.
303: Furnuss room; fire caulk gas pipe at the ceiling.
304: Furnuss room; fire caulk gas pipe at the ceiling.
105: Utility room; remove paper of sheetrock on the back side of the drywall at
the B vent.
106: Utility room; remove paper of sheetrock on the back side of the drywall at
the B vent.
108: Utility room; 1" is needed around the B vent.
Fire caulk around the drain pipe in bathroom.
Furnuss room: Fire caulk around the thermostat wire.
205 Utility; 1" needed aroun the B vent.
206 Gas Smell in unit
Fire caulk around vanity drain.
1" is needed around the B vent.
207 1" is needed around the B vent.
Extend drain pipe from water heater drain pan to the floor drain.
NOTE...... CHECK ALL WATER HEATER PANS.
208 Smoke/C.O. detector needed outside of Southwest bedroom NOTE....Check
all units with bedrooms on oppisite sides.
305: Drain pipe from water heater overflow pan neededs to extend to the floor
drain.
Furnuss room; Fire caulk around gas pipe in ceiling.
306:Furnuss room; Fire caulk around gas pipe in ceiling.
307:Utility room; Extend drain line from water heater overflow pan to the floor
drain.
308:Utility room; Extend drain line from water heater overflow pan to the floor
drain.
Fire caulk around the Southeast bathroom vanity drain line.
Inspector Comments:
03/17/2015FailTed DyeCommercial Building Final
Temp. C.O. may be issued till the landscaping is completed.Inspector Comments:
06/12/2015PassTed DyeCommercial Building Final
Electrical Inspection Type
11/03/2014PassBret StoddardCOM & MFR Electrical Service Inspection
11/10/2014PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
02/24/2015PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00402
Mesa Falls Apts Bldg #13
940 S 5th W
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 02/14/2020 9:43 am
Permit
Inspection
Summary
Fire Inspection Type
01/13/2015PassDale PickeringFire Sprinkler Hydro
02/09/2015FailDale PickeringFire Sprinkler Final Inspection
02/26/2015PassBret StoddardFire Alarm Final Inspection
03/10/2015PassBret StoddardFire Sprinkler Final Inspection
Mechanical Inspection Type
11/06/2014PassDon AllenHVAC Rough-in
All good to cover the mechanical rough in
Gas presser held at 60 lb on 25 of the units
Inspector Comments:
02/19/2015PassDon AllenHVAC Final Inspection
mech is good for the c/oInspector Comments:
Plumbing Inspection Type
08/18/2014PassDon AllenPlumbing Underground Inspection
Good to cover the under groundInspector Comments:
10/30/2014PassDon AllenPlumbing Rough-in
All good to cover rough inInspector Comments:
03/04/2015PassPLL ADMINPlumbing Final Inspection
**Completed by Brian Hill**Inspector Comments: