HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00371 - 665 Mill Stream - SFR HeinerPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/13/2020 4:16 pm Permit Details Permit Number: 12-00371 665 Mill Stream - SFR Heiner 665 Mill Stream New Single Family Residence Permit Issued Date: 07/01/2014 Permit Inspection Statistics 17Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 88.24% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 01/08/2012PassQuinton OwensSheetrock/Drywall Inspection Ok to tape drywall.Inspector Comments: 09/06/2012PassQuinton OwensFooting Inspection 09/13/2012PassQuinton OwensFoundation Inspection 1pm :clearances not met. 3pm: Rebar placement OK - clearances corrected. Inspector Comments: 12/19/2012PassQuinton OwensFraming/Structure Inspection Missed stapling some locations (marked in red crayon). Hold down on garage not nailed.(10-30) Sheathing completed (10-31, QO) Bracing missing on D05 & D06 trusses. Inspector Comments: 12/21/2012PassQuinton OwensInsulation Inspection REScheck with R-11 in basement approved, 12-26 (in file)Inspector Comments: 04/26/2013PassTed DyeSidewalk Inspection 6" gravel base.Inspector Comments: 05/08/2013FailTed DyeBuilding Final No house mounter on house 1 ladder required in basement window well Inspector Comments: 05/17/2013PassTed DyeBuilding Final ladder in place and house # on mail box brick stuctureInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00371 665 Mill Stream - SFR Heiner 665 Mill Stream New Single Family Residence Permit Status of (Open) as of Report Date: 02/13/2020 4:16 pm Permit Inspection Summary Electrical Inspection Type Approved to be energized for permanent power-Ufer clamp was changed to a listed type. Inspector Comments: 12/7/12 BS: Approved to be energized for permanent power-no seperate ticket was written-inspected this on the rough-in. Need to install a listed clamp for the rebar connection of the Ufer ground, and irreversible-will re-inspect on the final. Inspector Comments: 12/07/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover upstairs-unfinished basement-exterior walls are wired completely in basement and ceilings, no receptacles are installed on the stairway walls all around, inspected the electrical service on the rough-in inspection. Inspector Comments: 12/12/2012PassBret StoddardResidential Electrical Service Inspection Approved for cover upstairs-unfinished basement-exterior walls are wired completely in basement and ceilings, no receptacles are installed on the stairway walls all around, inspected the electrical service on the rough-in inspection. Inspector Comments: 05/02/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection All receptacles in garage must be GFCI protected, receptacle needed near railing in floor, all receptacles downstairs in basement must be GFCI protected-unfinished, instersystem bonding termination not installed outside by meter for utilities connection, no A/C unit installed, basement wired entirely, only one light is mounted on the front of the home-all others are blanked (4 total), call for a re-inspect when ready. Inspector Comments: 05/03/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-upstairs only, unfinished basement-wired entirely, A/C unit is not installed-disconnect only, two receptacles in the garage on the west wall down low are blanked off, 240V boxes in the southwest corner are blanked off with no receptacles installed. Inspector Comments: Mechanical Inspection Type 12/17/2012PassQuinton OwensHVAC Rough-in All good for the c/oInspector Comments: 05/16/2013PassDon AllenHVAC Final Inspection 5/2/13 DA: Need a 1" clearance around vent of water heater. Call for reinspect.Inspector Comments: Plumbing Inspection Type 09/21/2012PassDon AllenPlumbing Underground Inspection 10/31/2012PassDon AllenPlumbing Rough-in All good for the C/O.Inspector Comments: 05/16/2013PassDon AllenPlumbing Final Inspection 5/1/13 DA: Leak on tub needs to be fixed. Call for reinspect.Inspector Comments: Page 2 of 2