HomeMy WebLinkAboutENGINEER LETTER - M19-00137 - Coblentz - 2866 Mendoza Dr - Self Storage Facility02/12/20 Regency Storage Systems 10390 Bradford Road – Suite 140 Littleton, CO 80127 1-800-486-8415 Building Location: Rexburg, ID 83440 Job # 20-1499-CLE Building Size: 30x 245 x 8-6 This letter is to certify the above referenced building will be designed in accordance with the applicable sections of the American Institute of Steel Construction (AISC) and the American Iron and Steel Institute (AISI) design procedures and good engineering practices for the following loads. Loads are applied in accordance with the 2015 International Building Code. Seismic Design Category : D Risk Category: I Building is to be erected in accordance with “FOR CONSTRUCTION” erection drawings sealed by Rama Adhikary. Building construction type – Type IIB Noncombustible Dead Load………………….…………………..Metal Building Materials Wind Speed…………………………………….115 mph (3 sec gust) Exposure “C” I w = 1.0 Live Load………………………………………20 psf Collateral Load…………………………………None Ground Snow Load………………………… = 50 psf Ce = 1.0 Ct = 1.0 Is = 1.0 Roof Snow Load – ---- 0.7x1.0x1.0x1.0x50 = 35 psf (max) Basic Structural System and Seismic Resisting System = Light Framed Walls with Shear Panels The buyer is responsible for insuring all specified loads are in compliance with local regulatory authorities. This letter of certification applies solely to the steel building system and its component parts and especially excludes any foundation, masonry, general contract work, or parts supplied by anyone other than Regency Storage Systems Rama Adhikary, P.E. is not Engineer of Record for overall project. Respectfully, _________________ Rama Adhikary, P.E. Engineer 02/12/20