HomeMy WebLinkAboutENGINEER LETTER - M19-00137 - Coblentz - 2866 Mendoza Dr - Self Storage Facility02/12/20
Regency Storage Systems
10390 Bradford Road – Suite 140
Littleton, CO 80127
1-800-486-8415
Building Location: Rexburg, ID 83440
Job # 20-1499-CLE
Building Size: 30x 245 x 8-6
This letter is to certify the above referenced building will be designed in accordance with the
applicable sections of the American Institute of Steel Construction (AISC) and the American Iron and
Steel Institute (AISI) design procedures and good engineering practices for the following loads.
Loads are applied in accordance with the 2015 International Building Code.
Seismic Design Category : D
Risk Category: I
Building is to be erected in accordance with “FOR CONSTRUCTION” erection drawings sealed by
Rama Adhikary.
Building construction type – Type IIB Noncombustible
Dead Load………………….…………………..Metal Building Materials
Wind Speed…………………………………….115 mph (3 sec gust) Exposure “C” I w = 1.0
Live Load………………………………………20 psf
Collateral Load…………………………………None
Ground Snow Load………………………… = 50 psf Ce = 1.0 Ct = 1.0 Is = 1.0
Roof Snow Load – ---- 0.7x1.0x1.0x1.0x50 = 35 psf (max)
Basic Structural System and Seismic Resisting System = Light Framed Walls with Shear Panels
The buyer is responsible for insuring all specified loads are in compliance with local regulatory
authorities. This letter of certification applies solely to the steel building system and its component
parts and especially excludes any foundation, masonry, general contract work, or parts supplied by
anyone other than Regency Storage Systems
Rama Adhikary, P.E. is not Engineer of Record for overall project.
Respectfully,
_________________
Rama Adhikary, P.E.
Engineer
02/12/20