HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00307 - 626 Tanglewood Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/11/2020 1:11 pm Permit Details Permit Number: 12-00307 626 Tanglewood Dr - SFR 626 Tanglewood Dr New Single Family Residence Permit Issued Date: 06/26/2014 Permit Inspection Statistics 23Total Inspections Completed: 19Total Inspections Passed: Inspection Pass Rate: 82.61% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 07/25/2012PassPLL ADMINFooting Inspection Layout looks good. Footing and Rebar ok As per Jon Berry. Inspector Comments: 07/26/2012PassBret StoddardFoundation Inspection Approved to place concrete for the foundation-2 #4 rebars installed at the top portion of the walls and the rest of the rebar is spaced on 2 foot center grid, ufer is installed next to the conduits. Inspector Comments: 11/15/2012PassQuinton OwensSheeting Hold downs nailed Sheathing approved. OK to cover. Inspector Comments: 11/16/2012FailQuinton OwensFraming/Structure Inspection Truss details do not match installed trusses. Anchor bolts needed in bsmt bearing walls. A35 ties missing at cantilevers (per engineer) ties for trusses at bay windows missing. Inspector Comments: 11/29/2012PassQuinton OwensFraming/Structure Inspection 11/21 basement framing (bdrm & family room) 11/29 - Items for reinspect completed. Inspector Comments: 11/29/2012PassQuinton OwensInsulation Inspection Wndw U-factor=.34; R-19 in basement. Wndws & doors sealed.Walls blown fiberglass. 1" clearance req'd between B-vent and insulation. Inspector Comments: 12/11/2012PassQuinton OwensSheetrock/Drywall Inspection 12/11: living space approved; Garage not done.Inspector Comments: 12/13/2012PassQuinton OwensSidewalk Inspection 7/12/13 - Sidewalk finished. Approved as per Tedd Dye.Inspector Comments: 02/06/2013PassQuinton OwensBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00307 626 Tanglewood Dr - SFR 626 Tanglewood Dr New Single Family Residence Permit Status of (Open) as of Report Date: 02/11/2020 1:11 pm Permit Inspection Summary Electrical Inspection Type 08/22/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 11/16/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-unfinished basement entirely.Inspector Comments: 11/26/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the basement bedroom and living room-west side of the stairs room is not wired. Inspector Comments: 02/06/2013PassQuinton OwensSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-west room in the basement is not finished, the remaining portions are finished, no A/C unit was installed-15A breaker was installed for it. Inspector Comments: Mechanical Inspection Type 11/16/2012PassQuinton OwensHVAC Rough-in 02/06/2013PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 02/06/2012FailDon AllenPlumbing Final Inspection -Need to clean out bottom of meter pit, need to see curb stop. -Need to fix centers waist under kitchen sink (change out slip gaskets) (no tape) -Need to cut 30'' clean clearance in grunt of water heater. Inspector Comments: 02/08/2012PassDon AllenPlumbing Final Inspection All good for the c/o.Inspector Comments: 07/30/2012FailDon AllenPlumbing Underground Inspection sewer and warter need a 10 foot searpationInspector Comments: 08/16/2012PassPLL ADMINPlumbing Sewer Sewer looks good as per Nathan Wood.Inspector Comments: 08/16/2012PassPLL ADMINPlumbing Water Water looks good. As per Nathan Wood. Inspector Comments: 08/16/2012PassPLL ADMINPlumbing Underground Inspection As per Nathan Wood.Inspector Comments: 11/16/2012FailDon AllenPlumbing Rough-in toilet in the master bath is over 135 deg. with no cleanoutInspector Comments: 11/27/2012PassDon AllenPlumbing Rough-in Rough in is good to cover.Inspector Comments: Page 2 of 2