HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00302 - 358 Eagle Ct - Perez - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/10/2020 1:24 pm
Permit Details Permit Number: 12-00302
358 Eagle Ct - Perez - SFR
358 Eagle Ct
New Single Family Residence
Permit Issued Date: 06/25/2014
Permit Inspection Statistics
23Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 73.91%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
07/12/2012PassPLL ADMINFooting Inspection
07/23/2012PassQuinton OwensFoundation Inspection
Rebar approved, Ufer in footing.Inspector Comments:
10/08/2012PassQuinton OwensSheeting
Sheathing approved.Inspector Comments:
10/29/2012PassQuinton OwensSidewalk Inspection
Base Approved.Inspector Comments:
11/09/2012PassQuinton OwensFraming/Structure Inspection
Fireblocking required at dropped ceilings (batt insulation may be used). Attic
access not installed yet.
Inspector Comments:
11/19/2012PassQuinton OwensInsulation Inspection
Move insulation for 1" min clearance to FP vent. Add baffles in attic above bath
by kitchen. Fill gaps around windows and doors.
Blown Fiberglass in walls, window u-factor is .24, Foundation R-13.
Inspector Comments:
12/11/2012PassQuinton OwensSheetrock/Drywall Inspection
Upstairs & garage done 11/26, QO.
Basement fin 12/11.
Inspector Comments:
01/22/2013FailTed DyeBuilding Final
Access in garage needs trimmed and a lid installed
Handrail needed on front ext. stairs and in garage
handrail needed on stairs to basement.
fire blocking needed around duct in mech. room
ladder need in window well S.E. bedroom (Basement)
Blocking off opening on deck till stairs are installed.
3' landing needed at bottom of steps out of south garage door.
Provide insulation certificate and attach cable to electrical panel.
Inspector Comments:
04/24/2015FailTed DyeResidential Building Final
If you have any questions please call me at
Cell 716-1330
Office 372-2330
Ted
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00302
358 Eagle Ct - Perez - SFR
358 Eagle Ct
New Single Family Residence
Permit Status of (Open) as of Report Date: 02/10/2020 1:24 pm
Permit
Inspection
Summary
04/30/2015PassTed DyeResidential Building Final
04/30/2015PassCD InternCommercial Building Final
2/26/13 QO: Finish Handrails in garage with end returns to wall..Finish stairs &
landing off deck when weather permits.(temp. C.O.)
Inspector Comments:
Electrical Inspection Type
11/09/2012FailBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Need to install romex connectors in several locations throughout the dwelling,
need to install power to the fireplace and gas range, need power to the island for
a receptacle for the final, closet light clearance in office closet may not be
sufficient with shelving installed-will verify on the final or rough-in re-inspect,
short wall in the master bedroom needs a receptacle installed, jet tub does not
have circuits ran yet, call for a re-inspect when ready. Approved for cover in the
exterior walls only-insulation.
Inspector Comments:
11/13/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power, inspected the service on the
rough-in, therefore no separate ticket was written for the service only.
Inspector Comments:
11/13/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover, also inspected the electrical service on this inspection
therefore only this ticket was written.
Inspector Comments:
01/22/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Intersystem bonding termination not installed nby main panel, all garage
receptacles required to be GFCI protected, recessed can trims throughout the
entire house not installed, breaker blank needed in laundry panel, GFCI
protection required for laundry circuits upstairs and downstairs, under cabinet
lights not installed in the kitchen, covers missing in the theater for receptacles,
call for a re-inspect when ready for a temporary C.O.
Inspector Comments:
01/24/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved to issue a TEMPORARY C.O. only, garage doors not GFCI protected,
under cabinet light not installed, disposeall wire needs a flex for protection, will
re-inspect the entire house when issuing the final C.O.
Inspector Comments:
Mechanical Inspection Type
11/05/2012FailQuinton OwensHVAC Rough-in
Seal penetrations in floor plenums. Duct work will be re-done to fix cut top plate
in bearing wall.
Inspector Comments:
11/08/2012PassQuinton OwensHVAC Rough-in
mech rough-in okInspector Comments:
06/25/2014PassQuinton OwensHVAC Final Inspection
2/26/13 QO: Mech room - Mech. Room: 168k btuh requires 56 sq in. combustion
air vent. 8" round vent installed (~51 in2)plus under door space - OK. Reinspect
rest of Mech at later date.
Inspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00302
358 Eagle Ct - Perez - SFR
358 Eagle Ct
New Single Family Residence
Permit Status of (Open) as of Report Date: 02/10/2020 1:24 pm
Permit
Inspection
Summary
Plumbing Inspection Type
02/08/2012FailDon AllenPlumbing Final Inspection
need to finish the trim in the bathrooms
could have a temp c/o
Inspector Comments:
07/30/2012PassDon AllenPlumbing Underground Inspection
All good to cover the underground.Inspector Comments:
07/30/2012PassDon AllenPlumbing Rough-in
02/26/2013PassDon AllenPlumbing Final Inspection
All good for C/O.Inspector Comments:
Page 3 of 3