Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00289 - 455 Twisted Willow - SFRPermit Inspection Summary Permit Status of (Expired) as of Report Date: 02/07/2020 9:27 am Permit Details Permit Number: 12-00289 455 Twisted Willow - SFR 455 Twisted Willow New Single Family Residence Permit Issued Date: 07/30/2014 Permit Inspection Statistics 24Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 70.83% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 06/28/2012FailQuinton OwensResidential Footing Inspection Basement Footing ok to pour (6/28, QO) Garage footing to be 12" below undisturbed soil. Inspector Comments: 07/02/2012PassQuinton OwensResidential Footing Inspection Garage ok to pour.. about 12" deep.Inspector Comments: 07/03/2012PassQuinton OwensFoundation Inspection OK to pour.Inspector Comments: 09/05/2012FailQuinton OwensResidential Framing/Structure Inspection Finish nailing sheathing at missed locations (marked with crayon); Anchor bolts needed in bsmt bearing walls; Finish nailing truss hangers in garage and mstr bdrm. Draft stop required in floor trusses (approximately in 1/2); lateral bracing at bearing points per manufr'; bearing locations missed at back bdrm, mech rm, stairs, and bsmt bath; 6'8" min headroom required above stairs. Inspector Comments: 09/10/2012PassQuinton OwensResidential Framing/Structure Inspection Fix floor truss 2A bearing point.(approved 10-4, Quinton)Inspector Comments: 09/10/2012PassQuinton OwensResidential Insulation Inspection Insulate missed window header in Family Room.Windows & Doors not in yet need to inspect perimeter seal. Inspector Comments: 09/21/2012FailQuinton OwensResidential Sheetrock/Drywall Inspection Covered repair on Floor Truss 2A without inspection. Have not recieved revised floor truss approvals (email). Add screws to various missed locations. Mstr Bdrm & shower, living room, by stairs, middle bsmt bdrm, family room closet. Inspector Comments: 10/04/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection Recieved Floor truss approvals, inspected FT2A repair.Inspector Comments: 10/11/2012PassQuinton OwensSidewalk Inspection 5" to 6" of rock & sand.Inspector Comments: 11/20/2012FailQuinton OwensResidential Building Final Handrail req'd at front steps. Handrails in garage and at patio do not meet code. Guardrail on back door landing or cover over window well. CO detectors in the hallways. SD in Mstr Bdrm not interconnected (& living rm?) Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00289 455 Twisted Willow - SFR 455 Twisted Willow New Single Family Residence Permit Status of (Expired) as of Report Date: 02/07/2020 9:27 am Permit Inspection Summary 11/26/2012PassQuinton OwensResidential Building Final All previous items completed.Inspector Comments: Electrical Inspection Type 09/05/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-need to separate the grounded and grounding wires in the main panel on the ground bars, closet light is to close to the potential shelving in the master bedroom closet, will re-inspect these items on the final inspection. Inspector Comments: 10/05/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 11/20/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Master closet light to close to the shelving, receptacles in the front room and the west bedroom upstairs has open grounds, no power to the smoke detector in the master bedroom and living room upstairs, outside receptacle on the north side of the garage not weather rated, label the main panel, no inter-system bonding termination on the outside by the meter, no A/C unit is installed or breaker for it either, call for a re-inspect when ready. Inspector Comments: 11/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-no A/C unit is installed (40A breaker installed).Inspector Comments: Mechanical Inspection Type 09/05/2012PassQuinton OwensHVAC Rough-in Bsmt bath vent to extend outside. Wall stud cavities with return air need to have penetrations sealed. Inspector Comments: 11/16/2012FailQuinton OwensHVAC Final Inspection Comb. air vent is restricted by dampers at termination. Pull blue wire away from b-vent. Inspector Comments: 11/26/2012PassQuinton OwensHVAC Final Inspection Mech final complete.Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00289 455 Twisted Willow - SFR 455 Twisted Willow New Single Family Residence Permit Status of (Expired) as of Report Date: 02/07/2020 9:27 am Permit Inspection Summary Plumbing Inspection Type 07/16/2012PassDon AllenPlumbing Underground Inspection All good to cover.Inspector Comments: 09/05/2012PassDon AllenPlumbing Sewer 09/05/2012FailDon AllenPlumbing Rough-in need to vent toilet, trap arm for 1 1/2 can only be 30 inches longInspector Comments: 11/27/2012PassDon AllenPlumbing Water 11/27/2012PassDon AllenPlumbing Final Inspection All good for the C/OInspector Comments: 12/04/2012PassSAUREY AMANDAPlumbing Rough-in Approved per Don Allen.Inspector Comments: Page 3 of 3