Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00278 - 162 Star View Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/06/2020 10:29 am Permit Details Permit Number: 12-00278 162 Star View Dr - SFR 162 Star View Dr New Single Family Residence Permit Issued Date: 07/29/2014 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 06/21/2012PassPLL ADMINResidential Footing Inspection As per Jon Berry. Layout: reversed layout.. not ready with new layout.(6/19, QO) Inspector Comments: 06/26/2012PassQuinton OwensFoundation Inspection House layout reversed. Rebar as per city ord. OK to pour.Inspector Comments: 09/06/2012FailQuinton OwensResidential Framing/Structure Inspection Sheathing approved 8/6, Quinton. Holes too large in studs (dryer vent); Smoke det. must be at least 3' from ceiling fan blade (mstr bd); H1 truss tiedown not nailed in NE bedroom (1); Fireblocking needed at dropped ceilings; 1" clearance needed around FP vent in floor; Insulation R-value next to stairs to be R13 (may not have room). Anchor Bolts on Interior bearing walls (bsmt). Smoke Det on ceiling near bottom of stairs req'd. Fireblocking missed on tall walls above stair light switch and by back door. Inspector Comments: 09/10/2012FailQuinton OwensResidential Insulation Inspection 1" clearance around B-vent (insulation shield too high?).R-11 cavity insulation (REScheck required). 1' clearance around FP vents (floor and ext. wall). Gaps in foam seal around windows in Mstr bed & bath and laundry room. Also foam seal between studs by Mstr bth window and conduit penetrating top plate in hall closet. Inspector Comments: 09/12/2012PassQuinton OwensResidential Framing/Structure Inspection FixedInspector Comments: 09/12/2012FailQuinton OwensResidential Insulation Inspection All insulation corrections done except B-vent clearance at top of fluechase.Inspector Comments: 09/14/2012PassQuinton OwensResidential Insulation Inspection B-vent clearance not corrected as of 9-12. reinspected 9-14 Inspector Comments: 09/18/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection Missed some screws by basement fireplace.(space will be filled by cabinets).Inspector Comments: 10/17/2012FailQuinton OwensSidewalk Inspection About 5" of pit run with more gravel beneath. Portions of sidewalk not thick enough. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00278 162 Star View Dr - SFR 162 Star View Dr New Single Family Residence Permit Status of (Open) as of Report Date: 02/06/2020 10:29 am Permit Inspection Summary 10/18/2012PassQuinton OwensSidewalk Inspection 11/28/2012PassQuinton OwensResidential Building Final House # OKInspector Comments: Electrical Inspection Type 07/16/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 09/04/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-MC cable was installed for the 200A subpanels(2).Inspector Comments: 11/27/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-no A/C unit is installed (30A breaker).Inspector Comments: Mechanical Inspection Type 08/31/2012PassQuinton OwensHVAC Rough-in Basement Bath vent not in. Dryer vent - Holes too large in studs.Have items done by framing inspection. Inspector Comments: 11/28/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 07/16/2012PassDon AllenPlumbing Underground Inspection All good to cover.Inspector Comments: 07/16/2012PassDon AllenPlumbing Sewer 07/17/2012PassDon AllenPlumbing Water 08/20/2012PassSAUREY AMANDAPlumbing Rough-in 0816/2012: City pressure on water, water on DWV, good; per Nathan Wood.Inspector Comments: 11/27/2012PassDon AllenPlumbing Final Inspection All good for the C/OInspector Comments: Page 2 of 2