Permit Status of (Open) as of Report Date: 02/06/2020 10:29 am
Permit Details Permit Number: 12-00278
162 Star View Dr - SFR
162 Star View Dr
New Single Family Residence
Permit Issued Date: 07/29/2014
Permit Inspection Statistics
21Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 80.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
06/21/2012PassPLL ADMINResidential Footing Inspection
As per Jon Berry.
Layout: reversed layout.. not ready with new layout.(6/19, QO)
Inspector Comments:
06/26/2012PassQuinton OwensFoundation Inspection
House layout reversed. Rebar as per city ord. OK to pour.Inspector Comments:
09/06/2012FailQuinton OwensResidential Framing/Structure Inspection
Sheathing approved 8/6, Quinton.
Holes too large in studs (dryer vent); Smoke det. must be at least 3' from ceiling
fan blade (mstr bd); H1 truss tiedown not nailed in NE bedroom (1); Fireblocking
needed at dropped ceilings; 1" clearance needed around FP vent in floor;
Insulation R-value next to stairs to be R13 (may not have room). Anchor Bolts on
Interior bearing walls (bsmt). Smoke Det on ceiling near bottom of stairs req'd.
Fireblocking missed on tall walls above stair light switch and by back door.
Inspector Comments:
09/10/2012FailQuinton OwensResidential Insulation Inspection
1" clearance around B-vent (insulation shield too high?).R-11 cavity insulation
(REScheck required). 1' clearance around FP vents (floor and ext. wall). Gaps in
foam seal around windows in Mstr bed & bath and laundry room. Also foam seal
between studs by Mstr bth window and conduit penetrating top plate in hall
closet.
Inspector Comments:
09/12/2012PassQuinton OwensResidential Framing/Structure Inspection
FixedInspector Comments:
09/12/2012FailQuinton OwensResidential Insulation Inspection
All insulation corrections done except B-vent clearance at top of fluechase.Inspector Comments:
09/14/2012PassQuinton OwensResidential Insulation Inspection
B-vent clearance not corrected as of 9-12.
reinspected 9-14
Inspector Comments:
09/18/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
Missed some screws by basement fireplace.(space will be filled by cabinets).Inspector Comments:
10/17/2012FailQuinton OwensSidewalk Inspection
About 5" of pit run with more gravel beneath.
Portions of sidewalk not thick enough.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00278
162 Star View Dr - SFR
162 Star View Dr
New Single Family Residence
Permit Status of (Open) as of Report Date: 02/06/2020 10:29 am
Permit
Inspection
Summary
10/18/2012PassQuinton OwensSidewalk Inspection
11/28/2012PassQuinton OwensResidential Building Final
House # OKInspector Comments:
Electrical Inspection Type
07/16/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
09/04/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-MC cable was installed for the 200A subpanels(2).Inspector Comments:
11/27/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-no A/C unit is installed (30A breaker).Inspector Comments:
Mechanical Inspection Type
08/31/2012PassQuinton OwensHVAC Rough-in
Basement Bath vent not in. Dryer vent - Holes too large in studs.Have items done
by framing inspection.
Inspector Comments:
11/28/2012PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
07/16/2012PassDon AllenPlumbing Underground Inspection
All good to cover.Inspector Comments:
07/16/2012PassDon AllenPlumbing Sewer
07/17/2012PassDon AllenPlumbing Water
08/20/2012PassSAUREY AMANDAPlumbing Rough-in
0816/2012: City pressure on water, water on DWV, good; per Nathan Wood.Inspector Comments:
11/27/2012PassDon AllenPlumbing Final Inspection
All good for the C/OInspector Comments: