HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00265 - Clothing Store, RigbyPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/04/2020 1:05 pm Permit Details Permit Number: 12-00265 Clothing Store, Rigby 31 N 1st E Commercial New Rigby Permit Issued Date: 07/28/2014 Permit Inspection Statistics 21Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 71.43% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 06/21/2012PassPLL ADMINCommercial Footing Inspection As per Jon Berry.Inspector Comments: 06/22/2012PassPLL ADMINFoundation Inspection As per Jon Berry. OK. Foundation and rebar look good.Inspector Comments: 08/16/2012FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. Hold downs are missingInspector Comments: 08/20/2012FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. South entrance hold down not in shear wall cw ext sheathing not nailed per plans CW Several anchor bolts missing/loose nuts CW Anchor bolts required within 12" of each end with 2 min per board. CW Need truss details for bracing. Inspector Comments: 08/29/2012FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. Truss details do not match trusses.get correct drawings. Inspector Comments: 08/31/2012PassPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. OK to cover.Inspector Comments: 08/31/2012PassPLL ADMINCommercial Insulation Inspection As per Jon Berry.Inspector Comments: 09/05/2012PassPLL ADMINCommercial Sheetrock/Drywall Inspection As per Jon Berry. Mostly completed looks good Drywall nailing looks good- OK to cover. Wires covered in mech room. OK per Bret/ Quinton Inspector Comments: 11/13/2012FailQuinton OwensCommercial Building Final Building #'s missing. Strap Water Heater: Under sink pipe protectors (handicap). HC grab bars and toilet paper holder not installed. HC parking signs required. Inspector Comments: 11/14/2012FailQuinton OwensCommercial Building Final HC parking signs not up. Grab bars in wrong locations. Pipe protective covers not in. Outside comb. air vent not big enough for 120k btu. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00265 Clothing Store, Rigby 31 N 1st E Commercial New Rigby Permit Status of (Open) as of Report Date: 02/04/2020 1:05 pm Permit Inspection Summary 11/15/2012PassQuinton OwensCommercial Building Final All corrections completed. Electrical item for Bret: Wires in Mechanical room covered with drywall done. (11-16, QO) Inspector Comments: Electrical Inspection Type 08/10/2012PassBret StoddardCommercial Electrical Rough-in Approved for cover-also inspected the service on this inspection.Inspector Comments: 08/10/2012PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-no separate ticket was written for the service only-inspected on the rough-in. Inspector Comments: 11/13/2012FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection NM-B cabling in the mechanical room needs to be covered with a 15-minute finish rating-sheetrock, phase converter is not labeled and possibly not listed, call for a re-inspect when ready. Inspector Comments: 11/19/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-phase converter that was not listed and labeled is not installed, as per the owner they do not need to install it after they open their doors for business so it won't be installed at all-disconnect is installed and nothing is wired into it. Inspector Comments: Mechanical Inspection Type 08/08/2012PassPLL ADMINHVAC Rough-in HVAC insp. looks good.Inspector Comments: Plumbing Inspection Type 07/16/2012PassDon AllenPlumbing Underground Inspection All good to cover and move onInspector Comments: 08/13/2012PassSAUREY AMANDAPlumbing Rough-in DWV was at 0 PSI. Talked to Rod, he said it was on for a week Possibly seeped by the test plugs. Looked good otherwise. WARR test was good, per Nathan Wood. Inspector Comments: 11/13/2012PassDon AllenPlumbing Sewer 11/15/2012PassDon AllenPlumbing Water 11/15/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 2 of 2