Permit Details Permit Number: 12-00245
550 Foxhill Drive - Rigby - SFR
550 Foxhill Drive
Single Family Residence Rigby
Permit Issued Date: 07/28/2014
Permit Inspection Statistics
22Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 68.18%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
06/13/2012PassQuinton OwensCommercial Footing Inspection
2 cont. rebar in ftg's with clearances.Inspector Comments:
06/14/2012PassQuinton OwensFoundation Inspection
Footing out of square on garage front west corner. Rebar doweled and footing
extended to side for foundation support.
Inspector Comments:
08/02/2012FailQuinton OwensResidential Framing/Structure Inspection
Staple sheathing at missed locations (marked in crayon). 2 anchor bolts missing
in garage. Nails for hold down straps missed studs in NW corner and by front
entry. Also by front entry, corner tie-down not nailed to double stud. Truss tie
downs ("all trusses" per engineer). Secure North portion of East wall in
basement. Anchor Bolts needed in bsmt bearing walls.
Inspector Comments:
08/07/2012FailQuinton OwensResidential Insulation Inspection
Framing items not done. Windows & doors not installed & sealed. Finish
insulation at west end of floor. 1" clearance around B-vent.
Inspector Comments:
08/21/2012FailQuinton OwensResidential Framing/Structure Inspection
Previous items not completed. (Anchor bolts in garage & basement. H1's on each
truss) Repeated items include reinspect fee.
Inspector Comments:
08/21/2012PassQuinton OwensResidential Insulation Inspection
Replace insulation around shield protecting B-vent.Inspector Comments:
09/04/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
Approved with Exception: truss tie downs to be done on outside (if exterior wall
finish does not interfere with proper installation). Called Engr' office from site and
was told H2's are OK.
Inspector Comments:
12/10/2012FailQuinton OwensResidential Building Final
Insulation missing above door to cold storage room. Label dryer vent effective
length (+5' per 90 deg elbow). Need inspection or pictures of unapproved
framing items (garage anchor bolts and truss tie downs on jack trusses).
Inspector Comments:
08/05/2014PassTed DyeResidential Building Final
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00245
550 Foxhill Drive - Rigby - SFR
550 Foxhill Drive
Single Family Residence Rigby
Permit Status of (Open) as of Report Date: 02/03/2020 5:14 pm
Permit
Inspection
Summary
Electrical Inspection Type
06/25/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
07/31/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-need to install a receptacle in the floor by the railing on the
north side of railing for the final-unfinished basement entirely.
Inspector Comments:
11/07/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Need to install a receptacle in the floor near the north railing of the stairs, no
access to the jet tub motor, call for a re-inspect when ready.
Inspector Comments:
11/08/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement entirely.Inspector Comments:
Mechanical Inspection Type
08/02/2012FailQuinton OwensHVAC Rough-in
Connect bath vents to fans. Seal stud penetrations next to Return Air vents.Inspector Comments:
08/21/2012PassQuinton OwensHVAC Rough-in
12/10/2012PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
07/16/2012PassDon AllenPlumbing Underground Inspection
All good to cover.Inspector Comments:
09/21/2012PassDon AllenPlumbing Rough-in
All good to cover.Inspector Comments:
11/15/2012PassDon AllenPlumbing Sewer
11/15/2012PassDon AllenPlumbing Water
11/15/2012FailDon AllenPlumbing Final Inspection
the sink closes to the toilet needs to be changed. there can only be one trap on a
trap arm
Inspector Comments:
12/14/2012PassDon AllenPlumbing Final Inspection
All good for the C/OInspector Comments: