HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00245 - 550 Foxhill Dr - Rigby - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/03/2020 5:14 pm Permit Details Permit Number: 12-00245 550 Foxhill Drive - Rigby - SFR 550 Foxhill Drive Single Family Residence Rigby Permit Issued Date: 07/28/2014 Permit Inspection Statistics 22Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 68.18% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 06/13/2012PassQuinton OwensCommercial Footing Inspection 2 cont. rebar in ftg's with clearances.Inspector Comments: 06/14/2012PassQuinton OwensFoundation Inspection Footing out of square on garage front west corner. Rebar doweled and footing extended to side for foundation support. Inspector Comments: 08/02/2012FailQuinton OwensResidential Framing/Structure Inspection Staple sheathing at missed locations (marked in crayon). 2 anchor bolts missing in garage. Nails for hold down straps missed studs in NW corner and by front entry. Also by front entry, corner tie-down not nailed to double stud. Truss tie downs ("all trusses" per engineer). Secure North portion of East wall in basement. Anchor Bolts needed in bsmt bearing walls. Inspector Comments: 08/07/2012FailQuinton OwensResidential Insulation Inspection Framing items not done. Windows & doors not installed & sealed. Finish insulation at west end of floor. 1" clearance around B-vent. Inspector Comments: 08/21/2012FailQuinton OwensResidential Framing/Structure Inspection Previous items not completed. (Anchor bolts in garage & basement. H1's on each truss) Repeated items include reinspect fee. Inspector Comments: 08/21/2012PassQuinton OwensResidential Insulation Inspection Replace insulation around shield protecting B-vent.Inspector Comments: 09/04/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection Approved with Exception: truss tie downs to be done on outside (if exterior wall finish does not interfere with proper installation). Called Engr' office from site and was told H2's are OK. Inspector Comments: 12/10/2012FailQuinton OwensResidential Building Final Insulation missing above door to cold storage room. Label dryer vent effective length (+5' per 90 deg elbow). Need inspection or pictures of unapproved framing items (garage anchor bolts and truss tie downs on jack trusses). Inspector Comments: 08/05/2014PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00245 550 Foxhill Drive - Rigby - SFR 550 Foxhill Drive Single Family Residence Rigby Permit Status of (Open) as of Report Date: 02/03/2020 5:14 pm Permit Inspection Summary Electrical Inspection Type 06/25/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 07/31/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-need to install a receptacle in the floor by the railing on the north side of railing for the final-unfinished basement entirely. Inspector Comments: 11/07/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install a receptacle in the floor near the north railing of the stairs, no access to the jet tub motor, call for a re-inspect when ready. Inspector Comments: 11/08/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished basement entirely.Inspector Comments: Mechanical Inspection Type 08/02/2012FailQuinton OwensHVAC Rough-in Connect bath vents to fans. Seal stud penetrations next to Return Air vents.Inspector Comments: 08/21/2012PassQuinton OwensHVAC Rough-in 12/10/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 07/16/2012PassDon AllenPlumbing Underground Inspection All good to cover.Inspector Comments: 09/21/2012PassDon AllenPlumbing Rough-in All good to cover.Inspector Comments: 11/15/2012PassDon AllenPlumbing Sewer 11/15/2012PassDon AllenPlumbing Water 11/15/2012FailDon AllenPlumbing Final Inspection the sink closes to the toilet needs to be changed. there can only be one trap on a trap arm Inspector Comments: 12/14/2012PassDon AllenPlumbing Final Inspection All good for the C/OInspector Comments: Page 2 of 2