HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00244 - Pizza Hut, Rigby - Tenant FinishPermit Inspection Summary Permit Status of (Open) as of Report Date: 02/03/2020 4:47 pm Permit Details Permit Number: 12-00244 Pizza Hut, Rigby - Tenant Finish 205 Stockhman Blvd. Ste A-1 - Rigby Commercial Tenant Finish Rigby Permit Issued Date: 06/18/2014 Permit Inspection Statistics 15Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 93.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 07/12/2012PassQuinton OwensFraming/Structure Inspection 7/6 QO: Fire rated wall not required above ceiling.(based on all B-occupancies, typ). 5/8" drywall installed up to roof deck anyway on Pizza Hut side. 7/12 QO: framing ok Inspector Comments: 07/17/2012PassQuinton OwensInsulation Inspection 7/9, QO: R-19 Insulation installed behind Cooler location (NW corner) 7-17, QO: Walls R-19 done. Inspector Comments: 07/18/2012PassQuinton OwensSheetrock/Drywall Inspection Drywall OK to tape.Inspector Comments: 08/09/2012PassPLL ADMINInsulation Inspection 8/1 Duct Insulation - JB - Grease duct fire wrap looks good. HVAC ducting looks good 3in fire barrier. 8/9 insulation completed As per Jon Berry. Inspector Comments: 09/05/2012PassPLL ADMINBuilding Final Bldg final completed As per Jon Berry. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00244 Pizza Hut, Rigby - Tenant Finish 205 Stockhman Blvd. Ste A-1 - Rigby Commercial Tenant Finish Rigby Permit Status of (Open) as of Report Date: 02/03/2020 4:47 pm Permit Inspection Summary Electrical Inspection Type 07/13/2012PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in Approved for cover-need to strap up the MC cabling through out the ceiling-will re-inspect on the final through the ceiling tile. Inspector Comments: 08/09/2012FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Panels not labeled, time clock needs a connector installed to protect wires, GFCI protection required for receptacles within 6' from the edge of the sink(3), 60A breaker installed in panel for A/C units and the units show a 50A max, signs are UL listed and labeled and have disconnects installed on the sides of each sign, call for a re-inspect when ready. Inspector Comments: 08/10/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Fire Inspection Type 09/05/2012PassPLL ADMINFire Department Final Inspection as per Jon Berry.Inspector Comments: Mechanical Inspection Type 08/01/2012PassPLL ADMINHVAC Rough-in HVAC ducting looked good. Quinton checked insulation and grease ducting both hoods. (7/30) Grease duct insulation looked good. 2 layers 3M on both hoods. As per Jon Berry. Inspector Comments: Plumbing Inspection Type 07/16/2012PassDon AllenPlumbing Underground Inspection 7/5/12 DA: all good to cover.Inspector Comments: 08/10/2012PassDon AllenPlumbing Rough-in All good to cover.Inspector Comments: 08/10/2012PassDon AllenPlumbing Final Inspection All good for the C/O.Inspector Comments: 08/10/2012PassDon AllenPlumbing Sewer 08/10/2012PassDon AllenPlumbing Water Page 2 of 2