Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00213 - Darwin Matthews Apts - 6 Units & Site PlanPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/23/2020 11:08 am Permit Details Permit Number: 12-00213 Darwin Matthews Apts - 6 Units & Site Plan 467 S 5th W New Multi-Family Residence Permit Issued Date: 07/23/2014 Permit Inspection Statistics 19Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 89.47% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 06/15/2012PassPLL ADMINResidential Footing Inspection As per Jon Berry. Footings and rebar look good.Inspector Comments: 06/20/2012PassPLL ADMINFoundation Inspection As per Jon Berry. Foundation and rebar look good.Inspector Comments: 08/24/2012FailPLL ADMINResidential Framing/Structure Inspection As per Quinton Owens 8/14/12 - Sheathing - Missed locations marked on inside with crayon since bldg wrap was on. Block all sheathing edges. 5/8" drywall on North side (soffit in progress) Q As per Jon Berry 8/24/12 - Framing - HD2/3 hold downs req. screws not nails JB Q got ok from architect HD-1 straps missing/covered AB missing or missing nuts/washers CWjb AB missing bearing walls in basement CW jb Shear walls not nailed per plans CW jb Blocking missing in BW1 walls per plans CW jb Upstairs SW2 bottom plate not nailed per plans CW jb Inspector Comments: 09/17/2012PassPLL ADMINResidential Framing/Structure Inspection As per Jon Berry. Darin Geisler (GNS Struct. Engr) called and approved nails on tiedowns vs screws (8-28, QO) 8/31 HD1 straps missing dean says they were installed ?? covered JB BW1 wall needs cont. blocking CW jb Inspector Comments: 09/18/2012PassPLL ADMINCommercial Sheetrock/Drywall Inspection As per Jon Berry, 9/12/12 - Drywall nailing looks good. 9/18/12 - Basement drywall ok to cover. Inspector Comments: 10/15/2012PassPLL ADMINResidential Insulation Inspection As Per Jon Berry. Insulation looks good- OK to cover (ext walls)Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00213 Darwin Matthews Apts - 6 Units & Site Plan 467 S 5th W New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/23/2020 11:08 am Permit Inspection Summary 11/20/2012FailQuinton OwensResidential Building Final 11/9/12 - Fan blade cannot be withing 36' of smoke detector, Plumbing clearout covers on party walls need to be metal 11/20/12 - Handicap parking sign missing (60" min above ground). Unit 2: Smk detectors not interconnected. Inspector Comments: 12/04/2012PassQuinton OwensResidential Building Final SD's in Unit 2 working ok. (11-20 (pm), QO) HC parking sign installed.(12-4) 12/4/12 - As per Jon Berry - Fire Extinguisher Final OK Inspector Comments: Electrical Inspection Type 08/17/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 08/27/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-entire building.Inspector Comments: 11/09/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Fire Inspection Type 12/04/2012PassDale PickeringFire Sprinkler Hydro 8/23 Sprinkler hydro tested good 200# for building. per Jon BerryInspector Comments: 12/04/2012PassSAUREY AMANDAFire Sprinkler Final Inspection 12/04/2012PassSAUREY AMANDAFire Alarm Final Inspection 11/13/2012: Fire Alarm test completed. 24 hr battery test C/W, per Jon Berry.Inspector Comments: Mechanical Inspection Type 11/20/2012PassQuinton OwensHVAC Final Inspection Furniture in top east unit is covering wall heaters. Told tenants to keep required clearance in front of heaters (noted on top of heater). Inspector Comments: Plumbing Inspection Type 10/15/2012PassDon AllenPlumbing Sewer 10/15/2012PassDon AllenPlumbing Water 10/15/2012PassDon AllenPlumbing Rough-in 9-28-12 - H2O Test approved as well.Inspector Comments: 11/15/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 2 of 2