Loading...
HomeMy WebLinkAboutFIRE ALARM SYSTEM 2 - 19-00751 - 450 E Main St - Madison Memorial Conference Center RemodelFeatures Dual Contact Relay IAM (Individual Addressable Module):  A single addressable point provides control and status tracking of two, 2 A Form “C” contacts  Low power latching relay design allows IDNet or MAPNET II communications to supply both data and module power  Relay is set to OFF on initial power up and upon loss of IDNet or MAPNET II communications For use with following Simplex control panels:  Model Series 4007ES, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications  Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction:  Mounts in standard 4” (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11⁄16” square electrical box  Screw terminals for wiring connections  Visible LED flashes to indicate communications, can be selected at panel to indicate activated state  Optional 4” square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 Description Dual Contact Relay IAMs allow fire alarm control panels to control two remotely located Form “C” contact using IDNet or MAPNET II addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Product Selection Model Description 4090-9008 Dual Contact Relay IAM Optional Adapter Plates Model Description 4090-9813 Adapter plate to fit 4 11⁄16” (119 mm) square electrical box 4090-9801 For semi-flush mounted box Optional trim plate for 4” boxes with LED viewing window, includes mounting screws; galvanized steel 4090-9802 For surface mounted box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 1 2 4 8 16 32 64 128 4090-9008 Dual Contact Relay IAM (shown approximately 1/2 size) Specifications Communications IDNet or MAPNET II communications, 1 address per device Power Supplied by communications Installation Instructions 579-1040 IDNet Firmware Requires 3.12.04 or higher Contact Ratings* (not rated for incandescent switching) Type Dual Form C contacts (DPDT) with terminal block access to Common, N.O., and N.C for each contact Power-Limited 2 A @ 30 VDC, resistive from listed fire alarm supply 1 A @ 30 VDC, inductive Nonpower-Limited 0.5 A @ 125 VAC, resistive Relay Fusing Each contact common is fused with a 2 A fast acting non-time delay fuse * Provide external transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) IDNet or MAPNET II Communications Wiring Reference Up to 2500 ft ( 762 m) from control panel Up to 10,000 ft ( 3048 m) total wiring distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 ⅛” H x 4” W x 1 ⅜” D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C), intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Addressable Initiation Peripherals UL, ULC, CSFM Listed; IDNet and MAPNET II Communicating Devices FM Approved* Model 4090-9008 Dual Contact Relay IAM S4090-0014-3 11/2014 Optional Trim Plates for 4" Square Boxes with Visible LED 4090-9802, Trim plate for surface mounted box 4090-9801, Trim plate for semi-flush mounted box 4-9/16" (116 mm) 4-9/16" (116 mm) 4-5/16" (109 mm) Light pipe for LED viewing 4-5/16" (109 mm) Mounting Reference with 4-11/16" Square and 4" Square Boxes 4090-9008 Dual Contact Relay IAM Assembly 4090-9813 Adapter Plate for 4-11/16" square box (includes 2, #8 mounting screws) 4-11/16" (119 mm) square electrical box, 2-1/8" (54 mm) minimum depth (supplied separately) 4" (102 mm) square electrical box, 2-1/8" (54 mm) minimum depth (supplied separately) 4-11/16" or 4" square cover plate (supplied separately) Use mounting screws supplied with box Add supplied label to cover on-site if controlling 120 VAC Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4090-0014-3 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Dual Contact Relay IAM Mounting Information