Loading...
HomeMy WebLinkAboutGARAGE SHEARWALL - M19-00155 - Craner - 9828 S 400 W - New SFRNOTE: THE STRUCTURAL ENGINEER IS ONLY RE5PO515LE FOR THE LATERAL DE51GN OF TH15 GARAGE WALL W/ THE OVERHEAD GARAGE DOOR OPENINGS. ANY OTHER PART OF TH15 RESIDENCE 15 NOT THE KE5F0515LILITY OF THE STRUCTURAL ENGINEER. THE LATERAL LOADS WERE FOUND A55UMING THAT ALL EXTERIOR WALLS, INCLUDING THE GARAGE/HOUSE DEMISING WALL, ARE 5HEARWALL5 THAT CAN ADEQUATLY RESIST THE DE51GN LATERAL LOADS. DIMENSIONS FOR DE51GN WERE TAKEN FROM KEN MARSHA CKANEK RESIDENCE PLANS DATED 12/3 112015. HDUI I: 51MP50N HDU I 1-5D52.5 HOLDOWN W/ 51MP50N SB 1 X30 ANCHOR BOLT, INSTALL PER MANUFACTURER, MIN ANCHOR P05T SHALL 5E 4xG DOUG FIR WALL SHEATHING FOR ALL THREE WALL SEGMENTS OUTIDE AND INSIDE FACE: MIN 7/1 G" SHEATHING W1 8d NAILS @ 3" OC AT EDGES AND 12" OC IN FIELD, BLOCK ALL EDGES �S\pNAL F� ENSF� C/2 P-1 905 OF \OPS M10 01/15/2020 01 /15/2020 MIN 2xG @ I G" WALL FRAMING, TYP. J I I I I I I do II GARAGE DOOR OPENING PER ARCH'L PLANS I it I I I \ MIN 8" CONCRETE J/ WALL, TYF. UJ I I Q II QD I GARAGE DOOR I OPENING PER ARCH'L PLANS II LZ aJ— — — — — — — — GARAGE SHEARWALL SOI N.T.5 KEN CRANER GARAGE SHEARWALL S01 9828 S. 400 W., REXBURG, ID 83440 01/15/2020