HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00190 - 535 Woodbridge St - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am
Permit Details Permit Number: 12-00190
535 Woodbridge St - SFR
535 Woodbridge St
New Single Family Residence
Permit Issued Date: 06/13/2014
Permit Inspection Statistics
23Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 73.91%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/07/2012PassQuinton OwensFooting Inspection
Ok to pour footings.
Setbacks ok.
Inspector Comments:
05/10/2012PassQuinton OwensFoundation Inspection
Rebar 2' O.C. each way with 2 in top 12"
Garage wall 2 horz
vert. rebar <4' O.C. √
Inspector Comments:
06/26/2012FailQuinton OwensFraming/Structure Inspection
Approved upstairs.
Notched TJI under Bath tub (need approval from Manuf)
Block south end of return air plenum by mech room.
Inspector Comments:
06/28/2012FailQuinton OwensInsulation Inspection
Several windows short on foam seal. Vaulted walls not insulated as required at
peaks.
Bath vents not connected to fans
Inspector Comments:
07/06/2012PassQuinton OwensInsulation Inspection
OKInspector Comments:
07/13/2012FailQuinton OwensSheetrock/Drywall Inspection
Garage OK, Not done in house.
Insulation: Finish sealing windows. Did not have reinspection on bath fans.
Inspector Comments:
07/27/2012PassPLL ADMINSheetrock/Drywall Inspection
Reinspection looks good.
As per Jon Berry.
Inspector Comments:
08/23/2012PassQuinton OwensSidewalk Inspection
6" of crushed rock base.Inspector Comments:
09/26/2012FailQuinton OwensBuilding Final
Garage & Back stair handrail do not meet code. Egress ladder in at least one
window well.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00190
535 Woodbridge St - SFR
535 Woodbridge St
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am
Permit
Inspection
Summary
10/03/2012PassQuinton OwensFraming/Structure Inspection
Plladmin - Building final approved/ CO issued. Framing complete for these to
happen.
Inspector Comments:
10/03/2012PassQuinton OwensBuilding Final
final bldg/mech ok.Inspector Comments:
Electrical Inspection Type
06/25/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected on the rough-in, same
ticket.
Inspector Comments:
06/25/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-inspected the service on this inspection and no separate
ticket was written for the service-unfinished basement.
Inspector Comments:
09/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement-no A/C installed.Inspector Comments:
Mechanical Inspection Type
06/22/2012PassPLL ADMINHVAC Rough-in
HVAC rough looks good.
As per Jon Berry.
Inspector Comments:
09/26/2012FailQuinton OwensHVAC Final Inspection
B-vent to be protected in garage and needs 1" clearance to drywall. Lower water
heater strap not installed. Close off south end of plenum (between furnace and
stairs).
Inspector Comments:
10/03/2012PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
06/04/2012PassDon AllenPlumbing Sewer
06/04/2012PassDon AllenPlumbing Water
06/04/2012PassDon AllenPlumbing Underground Inspection
06/18/2012PassDon AllenPlumbing Rough-in
all good to cover.
8/30/12 DA: Shower pan - approved.
Inspector Comments:
09/26/2012FailDon AllenPlumbing Final Inspection
Needs stops in sinks in master bath.
Needs to stand bottom of water heater.
Inspector Comments:
10/04/2012PassDon AllenPlumbing Final Inspection
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00190
535 Woodbridge St - SFR
535 Woodbridge St
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am
Permit
Inspection
Summary
Page 3 of 3