Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00190 - 535 Woodbridge St - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am Permit Details Permit Number: 12-00190 535 Woodbridge St - SFR 535 Woodbridge St New Single Family Residence Permit Issued Date: 06/13/2014 Permit Inspection Statistics 23Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 73.91% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/07/2012PassQuinton OwensFooting Inspection Ok to pour footings. Setbacks ok. Inspector Comments: 05/10/2012PassQuinton OwensFoundation Inspection Rebar 2' O.C. each way with 2 in top 12" Garage wall 2 horz vert. rebar <4' O.C. √ Inspector Comments: 06/26/2012FailQuinton OwensFraming/Structure Inspection Approved upstairs. Notched TJI under Bath tub (need approval from Manuf) Block south end of return air plenum by mech room. Inspector Comments: 06/28/2012FailQuinton OwensInsulation Inspection Several windows short on foam seal. Vaulted walls not insulated as required at peaks. Bath vents not connected to fans Inspector Comments: 07/06/2012PassQuinton OwensInsulation Inspection OKInspector Comments: 07/13/2012FailQuinton OwensSheetrock/Drywall Inspection Garage OK, Not done in house. Insulation: Finish sealing windows. Did not have reinspection on bath fans. Inspector Comments: 07/27/2012PassPLL ADMINSheetrock/Drywall Inspection Reinspection looks good. As per Jon Berry. Inspector Comments: 08/23/2012PassQuinton OwensSidewalk Inspection 6" of crushed rock base.Inspector Comments: 09/26/2012FailQuinton OwensBuilding Final Garage & Back stair handrail do not meet code. Egress ladder in at least one window well. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00190 535 Woodbridge St - SFR 535 Woodbridge St New Single Family Residence Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am Permit Inspection Summary 10/03/2012PassQuinton OwensFraming/Structure Inspection Plladmin - Building final approved/ CO issued. Framing complete for these to happen. Inspector Comments: 10/03/2012PassQuinton OwensBuilding Final final bldg/mech ok.Inspector Comments: Electrical Inspection Type 06/25/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected on the rough-in, same ticket. Inspector Comments: 06/25/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-inspected the service on this inspection and no separate ticket was written for the service-unfinished basement. Inspector Comments: 09/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished basement-no A/C installed.Inspector Comments: Mechanical Inspection Type 06/22/2012PassPLL ADMINHVAC Rough-in HVAC rough looks good. As per Jon Berry. Inspector Comments: 09/26/2012FailQuinton OwensHVAC Final Inspection B-vent to be protected in garage and needs 1" clearance to drywall. Lower water heater strap not installed. Close off south end of plenum (between furnace and stairs). Inspector Comments: 10/03/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 06/04/2012PassDon AllenPlumbing Sewer 06/04/2012PassDon AllenPlumbing Water 06/04/2012PassDon AllenPlumbing Underground Inspection 06/18/2012PassDon AllenPlumbing Rough-in all good to cover. 8/30/12 DA: Shower pan - approved. Inspector Comments: 09/26/2012FailDon AllenPlumbing Final Inspection Needs stops in sinks in master bath. Needs to stand bottom of water heater. Inspector Comments: 10/04/2012PassDon AllenPlumbing Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 12-00190 535 Woodbridge St - SFR 535 Woodbridge St New Single Family Residence Permit Status of (Open) as of Report Date: 01/22/2020 8:12 am Permit Inspection Summary Page 3 of 3