Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00169 - 2365 W 960 S - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/15/2020 2:25 pm Permit Details Permit Number: 12-00169 2365 W 960 S - SFR 2365 W 960 S New Single Family Residence Permit Issued Date: 07/21/2014 Permit Inspection Statistics 17Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 94.12% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/25/2012PassPLL ADMINResidential Footing Inspection As per Jon Berry. Footings and rebar look good. OK to pour.Inspector Comments: 04/26/2012PassQuinton OwensFoundation Inspection Ufer ground installed. OK to pour.Inspector Comments: 05/29/2012PassQuinton OwensCommercial Framing/Structure Inspection 5/17/12 - Sheathing inspected from inside. House wrapped - fastener spacing not checked (5-21, QO) 5/25/12 - Bsmt Bdrm: 2 holes in floor plenum to be sealed and blocking needed for nailing drywall at ceiling along wall next to bathroom. Mstr Bd.- Furring strips in window may interfere with sealing around window. 36" landing at bottom of stairs (not quite) Inspector Comments: 06/04/2012PassQuinton OwensCommercial Insulation Inspection Windows sealed and have U-factor of .34 - .35. Blown fiberglass in exterior walls. R-13 on foundation walls. Doors sealed. Inspector Comments: 06/05/2012PassQuinton OwensCommercial Sheetrock/Drywall Inspection OK to tape.Inspector Comments: 07/16/2012PassQuinton OwensResidential Building Final Electrical Inspection Type 05/04/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-Ufer clamp not listed for rebar connection-will re-inspect on the rough-in inspection. Inspector Comments: 05/29/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-grounding electrode clamp on rebar not listed for rebar-will re-inspect on the final, must be irreversible type if covering in wall. Inspector Comments: 07/09/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-finished basement, no A/C unit was installed(20A breaker). Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00169 2365 W 960 S - SFR 2365 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 01/15/2020 2:25 pm Permit Inspection Summary Mechanical Inspection Type 05/24/2012PassQuinton OwensHVAC Rough-in Comb. air source for WH?Inspector Comments: 07/09/2012FailQuinton OwensHVAC Final Inspection Bath fans not done. WH vent connector not installed. Gas hookups not done. Extend Furnace condensate pipe to drain. Inspector Comments: 07/16/2012PassQuinton OwensHVAC Final Inspection Mech final OKInspector Comments: Plumbing Inspection Type 05/01/2012PassDon AllenPlumbing Sewer 05/01/2012PassDon AllenPlumbing Water 05/01/2012PassDon AllenPlumbing Underground Inspection 06/04/2012PassDon AllenPlumbing Rough-in 07/05/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 2 of 2