Permit Status of (Open) as of Report Date: 01/15/2020 2:25 pm
Permit Details Permit Number: 12-00169
2365 W 960 S - SFR
2365 W 960 S
New Single Family Residence
Permit Issued Date: 07/21/2014
Permit Inspection Statistics
17Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 94.12%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/25/2012PassPLL ADMINResidential Footing Inspection
As per Jon Berry. Footings and rebar look good. OK to pour.Inspector Comments:
04/26/2012PassQuinton OwensFoundation Inspection
Ufer ground installed. OK to pour.Inspector Comments:
05/29/2012PassQuinton OwensCommercial Framing/Structure Inspection
5/17/12 - Sheathing inspected from inside. House wrapped - fastener spacing not
checked (5-21, QO)
5/25/12 - Bsmt Bdrm: 2 holes in floor plenum to be sealed and blocking needed
for nailing drywall at ceiling along wall next to bathroom.
Mstr Bd.- Furring strips in window may interfere with sealing around window.
36" landing at bottom of stairs (not quite)
Inspector Comments:
06/04/2012PassQuinton OwensCommercial Insulation Inspection
Windows sealed and have U-factor of .34 - .35. Blown fiberglass in exterior walls.
R-13 on foundation walls. Doors sealed.
Inspector Comments:
06/05/2012PassQuinton OwensCommercial Sheetrock/Drywall Inspection
OK to tape.Inspector Comments:
07/16/2012PassQuinton OwensResidential Building Final
Electrical Inspection Type
05/04/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-Ufer clamp not listed for rebar
connection-will re-inspect on the rough-in inspection.
Inspector Comments:
05/29/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-grounding electrode clamp on rebar not listed for rebar-will
re-inspect on the final, must be irreversible type if covering in wall.
Inspector Comments:
07/09/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-finished basement, no A/C unit was installed(20A
breaker).
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00169
2365 W 960 S - SFR
2365 W 960 S
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/15/2020 2:25 pm
Permit
Inspection
Summary
Mechanical Inspection Type
05/24/2012PassQuinton OwensHVAC Rough-in
Comb. air source for WH?Inspector Comments:
07/09/2012FailQuinton OwensHVAC Final Inspection
Bath fans not done. WH vent connector not installed. Gas hookups not done.
Extend Furnace condensate pipe to drain.
Inspector Comments:
07/16/2012PassQuinton OwensHVAC Final Inspection
Mech final OKInspector Comments:
Plumbing Inspection Type
05/01/2012PassDon AllenPlumbing Sewer
05/01/2012PassDon AllenPlumbing Water
05/01/2012PassDon AllenPlumbing Underground Inspection
06/04/2012PassDon AllenPlumbing Rough-in
07/05/2012PassDon AllenPlumbing Final Inspection
All good for C/OInspector Comments: