Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00156 - 273 S 5th W - Campus Courtyard Bldg #1 - 21 PlexPermit Inspection Summary Permit Status of (Issue) as of Report Date: 01/13/2020 4:14 pm Permit Details Permit Number: 12-00156 273 S 5th W - Campus Courtyard Bldg #1 - 21 Plex 273 S 5th W New Multi-Family Residence Permit Issued Date: 03/04/2014 Permit Inspection Statistics 31Total Inspections Completed: 27Total Inspections Passed: Inspection Pass Rate: 87.10% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/10/2012PassPLL ADMINFooting Inspection Footings ok to pour on #1 Finish hanging rebar 2-uffers west end Interior footings/heated slab on grad approved (6/27,QO) Hydronic heating still holding pressure (7/3, QO) -As per Jon Berry Inspector Comments: 9/13/12 JB: ext. sheathing ok to cover questions about shear wall and sheathing at rim board and at wall joints Inspector Comments: 12/4, QO: Perimeter Exterior wall OK to insulate.Firecaulking, Framing - OKInspector Comments: 2/11: Need to finish sealing tub drain penetrations.Inspector Comments: 02/19/2013PassQuinton OwensFraming/Structure Inspection 2/19: Firecaulking done. OK to insulate interior and drywall.Inspector Comments: 02/19/2013PassQuinton OwensInsulation Inspection during fire caulking reinspect - ok to finish insulating and drywall.Inspector Comments: 3/21, QO: 3rd floor ok to tape drywall.Inspector Comments: 4/12 , QO: 2nd floor ok to tape (All 5/8" type x, double on ceiling).Inspector Comments: 4/16, QO: 1st floor done.Inspector Comments: 04/16/2013PassQuinton OwensSheetrock/Drywall Inspection 4/29, QO: Mechanical Room Drywall approved for taping.Inspector Comments: 06/03/2013Pass Sidewalk Inspection side walk along road had 6"to8"and 12" in places rebar: 18" on center both ways in approach and sidewalk Approved to pour side walk from south property boundary to north property line, also the approach Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 12-00156 273 S 5th W - Campus Courtyard Bldg #1 - 21 Plex 273 S 5th W New Multi-Family Residence Permit Status of (Issue) as of Report Date: 01/13/2020 4:14 pm Permit Inspection Summary 08/22/2013FailQuinton OwensBuilding Final 8/22,QO: ADA unit needs under sink protection. floor transition less than 1/2" or beveled transition. Hole behind fire ring under kitchen sink in several units is too large and needs firecaulking. Firecaulk penetrations under bathroom sink and metal escutcheons on 1st floor. Inspector Comments: 11/20/2013FailQuinton OwensBuilding Final Apt. units completed - finish fire caulking on rated walls in data & mech. rooms. Handicap parking signs not installed yet. Inspector Comments: 11/20/2013PassQuinton OwensCommercial Building Final Re-inspected with other buildings 1/27/14. Went to each building with Dean Green. Inspector Comments: 03/06/2014PassPLL ADMINFoundation Inspection -Rebar supported in footings -Insulation under slab. -No kinks in hydronic tubing found. -Hydronic tubing under pressure at about 60 psi (reinspect after pour). 7-3 Still at about 60 psi as before. OK Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 12-00156 273 S 5th W - Campus Courtyard Bldg #1 - 21 Plex 273 S 5th W New Multi-Family Residence Permit Status of (Issue) as of Report Date: 01/13/2020 4:14 pm Permit Inspection Summary Electrical Inspection Type 01/11/2012Pass COM & MFR Electrical Service Inspection 01/11/2012Pass SFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-SE cables throughout the building-also inspected the services on this rough-in inspection. Inspector Comments: 01/11/2012PassBret StoddardElectrical Underground Inspection -Approved for Cover-SE Cables throughout Building. -Service Approved to be energized for permanent power -Approved to be energized for permanent power-2 services, inspected the service on the rough-in SE cable inspection Inspector Comments: 04/12/2012PassPLL ADMINCommercial Electrical Rough-in Approved for Cover on Exterior walls only except on West wall SE cables, don't cover. Inspector Comments: 12/04/2012Pass Commercial Electrical Rough-in Approved for cover in the outside walls only, do not cover in the west wall where the SER cables are to be installed. Inspector Comments: 02/20/2013Pass SFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the commons walls between all units in all three levels.Inspector Comments: 08/19/2013Fail COM, COM-A, COM-R, and COM-T Electrical Final Inspection 1102 has has reverse polarity in the kitchen, 1202 has bathroom switch upside down, call for a re-inspect when ready. Inspector Comments: 08/22/2013Pass COM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final-all units only for electrical. Inspected the fire alarm for a final on this inspection also. Managers unit and mechanical room not finished for this building and building #2. Inspector Comments: 11/19/2013Pass COM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O. building #1.Inspector Comments: 02/19/2014Pass COM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O. entire building.Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 12-00156 273 S 5th W - Campus Courtyard Bldg #1 - 21 Plex 273 S 5th W New Multi-Family Residence Permit Status of (Issue) as of Report Date: 01/13/2020 4:14 pm Permit Inspection Summary Fire Inspection Type 06/14/2012PassDale PickeringFire Sprinkler Hydro Underground pressure tested good at 200 psi, street to hydrant and to building. Approved as per Jon Berry. Inspector Comments: 02/11/2013PassDale PickeringFire Sprinkler Hydro hydro - 200psu fir 2 hrs - ok rough in - ok. Inspector Comments: 08/22/2013Pass Fire Alarm Final Inspection Witnessed fire alarm operation entirely, 24 hour/5 minute test completed with A/C power loss on 8/21 8:30AM and A/C power restored at 9:15AM on 8/22, fire alarm inspection report in file. Inspector Comments: 10/21/2013Pass Fire Sprinkler Final Inspection 11:00 #210 pass 13:00 #210 pass Inspector Comments: 11/19/2013Fail Fire Department Final Inspection keys for knox box sheet rock in mech. room hydrant painted red. Inspector Comments: Mechanical Inspection Type 02/19/2013PassQuinton OwensHVAC Rough-in In floor heating on upper floors insp. by Jon?Inspector Comments: 08/22/2013PassQuinton OwensHVAC Final Inspection 8/22,QO: apartments' mechanical ok. need final on Mechanical rom and "office/storage"? Inspector Comments: Plumbing Inspection Type 05/30/2012PassDon AllenPlumbing Underground Inspection All good to coverInspector Comments: 11/27/2012Pass Plumbing Rough-in 11/20 -rough in is all ok.Inspector Comments: 09/03/2013Pass Plumbing Sewer 09/03/2013Pass Plumbing Water 09/03/2013Pass Plumbing Final Inspection All good for the c/oInspector Comments: Page 4 of 4