HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00154 - 565 Pioneer Rd - Rockcreek Townhome #126Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/13/2020 3:12 pm Permit Details Permit Number: 12-00154 565 Pioneer Rd - Rockcreek Townhome #126 565 Pioneer Rd New Single Family Residence Permit Issued Date: 06/12/2014 Permit Inspection Statistics 20Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 85.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/12/2012PassQuinton OwensFooting Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 04/12/2012PassQuinton OwensFoundation Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 06/07/2012FailQuinton OwensFraming/Structure Inspection Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full depth blocking required for lateral support and complete fire rating. Drywall behind tubs on firewall. Some studs missing under girder truss bearings. Access in wall to crawl space access is smaller than floor access opening. Inspector Comments: 06/19/2012PassQuinton OwensFraming/Structure Inspection 06/19/2012PassQuinton OwensInsulation Inspection Ok to drywall. Blown cellulose insulation. Window and door perimeters sealed. window u-factor crawl space perimeter insulated (with supply and transfer vents) Inspector Comments: 06/25/2012FailQuinton OwensSheetrock/Drywall Inspection Approved for taping. Separation not complete at base of garage walls.Inspector Comments: 08/13/2012PassQuinton OwensSheetrock/Drywall Inspection 08/13/2012PassQuinton OwensBuilding Final Address on street side. √ 8-16QO Verify with EMS. Inspector Comments: 08/14/2012PassQuinton OwensSidewalk Inspection not a street sidewalkInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00154 565 Pioneer Rd - Rockcreek Townhome #126 565 Pioneer Rd New Single Family Residence Permit Status of (Open) as of Report Date: 01/13/2020 3:12 pm Permit Inspection Summary Electrical Inspection Type 06/06/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in unit #126 only.Inspector Comments: 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-all 6 meters.Inspector Comments: 08/02/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Receptacle required in island-kitchen, water heater not installed, furnace not wired in, A/C units are not installed on roof top-30A OCPD installed, cannot final until these are installed, call for a re-inspect when ready. Inspector Comments: 08/13/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 06/14/2012PassPLL ADMINHVAC Rough-in HVAC rough looked good. As per Jon Berry. Inspector Comments: 08/03/2012PassQuinton OwensHVAC Final Inspection Guardrails/platform/access required for AC unit on roof? No - nothing in IRC for rooftop units. Inspector Comments: Plumbing Inspection Type 08/10/2012PassDon AllenPlumbing Sewer 08/10/2012PassDon AllenPlumbing Underground Inspection 08/10/2012PassDon AllenPlumbing Water 08/10/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: 11/07/2012PassDon AllenPlumbing Rough-in PCWInspector Comments: Page 2 of 2