Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00153 - 565 Pioneer Rd - Rockcreek Townhome #125Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/10/2020 11:24 am Permit Details Permit Number: 12-00153 565 Pioneer Rd - Rockcreek Townhome #125 565 Pioneer Rd New Single Family Residence Permit Issued Date: 06/11/2014 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/12/2012PassQuinton OwensFooting Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 04/12/2012PassQuinton OwensFoundation Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 06/07/2012FailQuinton OwensFraming/Structure Inspection Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full depth blocking required for lateral support and complete fire rating. Drywall behind tubs on firewall. Some studs missing under girder truss bearings. Access in wall to crawl space access is smaller than floor access opening. Inspector Comments: 06/19/2012PassQuinton OwensFraming/Structure Inspection 06/19/2012PassQuinton OwensInsulation Inspection finish overburn protection at roof peak for reinspection.(rest of framing items ok) 6/22 JB: C/N see areas ok concern must have replaced drywall sheet Inspector Comments: 06/26/2012PassQuinton OwensSheetrock/Drywall Inspection 09/27/2012FailQuinton OwensBuilding Final Verify gaps at peak and roof vent in overburn protection have been fixed. Upper handrail missing. Inspector Comments: 10/05/2012FailQuinton OwensBuilding Final Handrail height to be 34" min to 38" max above front edge of tread.Inspector Comments: 10/30/2012PassQuinton OwensBuilding Final building final ok.Inspector Comments: 11/27/2012PassQuinton OwensSidewalk Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 12-00153 565 Pioneer Rd - Rockcreek Townhome #125 565 Pioneer Rd New Single Family Residence Permit Status of (Open) as of Report Date: 01/10/2020 11:24 am Permit Inspection Summary Electrical Inspection Type 06/11/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-unit # 125 only.Inspector Comments: 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-all 6 meters.Inspector Comments: 09/26/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection GFCI in master bathroom won't reset, breaker lock is on dryer circuit-need on water heater circuit, call for a re-inspect when ready. Inspector Comments: 10/01/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 06/14/2012PassPLL ADMINHVAC Rough-in HVAC rough looked good. As per Jon Berry. Inspector Comments: 09/27/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 09/21/2012PassDon AllenPlumbing Water 09/21/2012PassDon AllenPlumbing Sewer 09/21/2012PassDon AllenPlumbing Underground Inspection 09/21/2012PassDon AllenPlumbing Rough-in 09/21/2012PassDon AllenPlumbing Final Inspection Page 2 of 2