Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00152 - 565 Pioneer Rd - Rockcreek Townhome #124Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/10/2020 11:18 am Permit Details Permit Number: 12-00152 565 Pioneer Rd - Rockcreek Townhome #124 565 Pioneer Rd New Single Family Residence Permit Issued Date: 06/10/2014 Permit Inspection Statistics 19Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 84.21% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/12/2012PassQuinton OwensFooting Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 04/12/2012PassQuinton OwensFoundation Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 06/07/2012FailQuinton OwensFraming/Structure Inspection Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full depth blocking required for lateral support and complete fire rating. Drywall behind tubs on firewall. Some studs missing under girder truss bearings. Access in wall to crawl space access is smaller than floor access opening. Inspector Comments: 06/19/2012PassQuinton OwensFraming/Structure Inspection Overburn protection incomplete at peak. see drywall insp. for complete approval.Inspector Comments: 06/26/2012PassQuinton OwensInsulation Inspection Patch overburn protection at roof peak and any roof vents in protected area.Inspector Comments: 06/29/2012PassQuinton OwensSheetrock/Drywall Inspection Overburn complete at peak? Finish garage drywall (2 layers)Inspector Comments: 08/24/2012FailQuinton OwensBuilding Final Handrail not installed. Bath fans not completed. CO det. required in hallway. Need ladder to see attic space (overburn at peak). Inspector Comments: 09/06/2012PassQuinton OwensBuilding Final Final OkInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00152 565 Pioneer Rd - Rockcreek Townhome #124 565 Pioneer Rd New Single Family Residence Permit Status of (Open) as of Report Date: 01/10/2020 11:18 am Permit Inspection Summary Electrical Inspection Type 06/15/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in unit #124 only.Inspector Comments: 06/29/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-#124.Inspector Comments: 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-all 6 meters.Inspector Comments: 08/24/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install receptacle on the island, bath fans are not installed, GFCI protection required for the receptacle on the west wall of the garage, furnace and water heater are not installed, call for a re-inspect when ready. Inspector Comments: Mechanical Inspection Type 06/14/2012PassPLL ADMINHVAC Rough-in HVAC Rough looked good. As per Jon Berry. Inspector Comments: 08/24/2012PassQuinton OwensHVAC Final Inspection Bath fans not in yet (see bldg final)Inspector Comments: Plumbing Inspection Type 08/31/2012PassDon AllenPlumbing Sewer 08/31/2012PassDon AllenPlumbing Water 08/31/2012PassDon AllenPlumbing Underground Inspection 08/31/2012PassDon AllenPlumbing Rough-in 08/31/2012PassDon AllenPlumbing Final Inspection all good for C/O.Inspector Comments: Page 2 of 2