HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00151 - 565 Pioneer Rd - Rockcreek Townhome #123Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/10/2020 11:10 am
Permit Details Permit Number: 12-00151
565 Pioneer Rd - Rockcreek Townhome #123
565 Pioneer Rd
New Single Family Residence
Permit Issued Date: 06/10/2014
Permit Inspection Statistics
19Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 78.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/12/2012PassQuinton OwensFooting Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
04/12/2012PassQuinton OwensFoundation Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
06/07/2012FailQuinton OwensFraming/Structure Inspection
Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full
depth blocking required for lateral support and complete fire rating. Drywall
behind tubs on firewall. Some studs missing under girder truss bearings. Access
in wall to crawl space access is smaller than floor access opening.
Inspector Comments:
06/19/2012PassQuinton OwensFraming/Structure Inspection
Overburn protection incomplete. see drywall insp. for approval.Inspector Comments:
06/26/2012PassQuinton OwensInsulation Inspection
Patch overburn protection at roof peak and any roof vents in protected area.Inspector Comments:
07/09/2012PassQuinton OwensSheetrock/Drywall Inspection
overburn complete at peak?
Finish screwing backwall of main bath.
Inspector Comments:
10/30/2012FailQuinton OwensBuilding Final
SD and CO det. not operational. Crawl space conditioned with vents to
outside.Weatherstripping missing on doors.
Inspector Comments:
11/26/2012FailQuinton OwensBuilding Final
Hallway missing CO detector. Previous items completed except Sm.Det & crawl
space not insulated to R-30 per code (need REScheck) and supply vent not
sealed closed. (ALL UNITS must comply)
Inspector Comments:
12/10/2012PassQuinton OwensBuilding Final
Bldg and Mech final ok
Pending REScheck - Ok, in file with 12-00149.
Action req: seal sup vent to crawl space
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00151
565 Pioneer Rd - Rockcreek Townhome #123
565 Pioneer Rd
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/10/2020 11:10 am
Permit
Inspection
Summary
Electrical Inspection Type
06/15/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in unit #123 only.Inspector Comments:
07/23/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-all 6 meters.Inspector Comments:
10/30/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Smoke detector not installed in the hallway upstairs, receptacle not completely
covered in the cabinet above the range-microwave-1/8" max, call for a re-inspect
when ready.
Inspector Comments:
11/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical Inspection Type
06/14/2012PassPLL ADMINHVAC Rough-in
HVAC rough looked good.
As per Jon Berry.
Inspector Comments:
10/30/2012PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
10/19/2012PassDon AllenPlumbing Sewer
10/19/2012PassDon AllenPlumbing Underground Inspection
10/19/2012PassDon AllenPlumbing Rough-in
10/19/2012PassDon AllenPlumbing Final Inspection
Page 2 of 2