Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00150 - 565 Pioneer Rd - Rockcreek Townhome #122Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/10/2020 11:08 am Permit Details Permit Number: 12-00150 565 Pioneer Rd - Rockcreek Townhome #122 565 Pioneer Rd New Single Family Residence Permit Issued Date: 06/10/2014 Permit Inspection Statistics 20Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 80.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/12/2012PassQuinton OwensFooting Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 04/12/2012PassQuinton OwensFoundation Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 06/07/2012FailQuinton OwensFraming/Structure Inspection Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full depth blocking required for lateral support and complete fire rating. Drywall behind tubs on firewall. Some studs missing under girder truss bearings. Access in wall to crawl space access is smaller than floor access opening. Inspector Comments: 06/19/2012PassQuinton OwensFraming/Structure Inspection overburn protection incomplete. see drywall insp. for approval.Inspector Comments: 06/26/2012PassQuinton OwensInsulation Inspection Patch overburn protection at roof peak and any roof bent in protected area.Inspector Comments: 07/11/2012PassQuinton OwensSheetrock/Drywall Inspection Overburn complete at peak?Inspector Comments: 10/30/2012FailQuinton OwensBuilding Final Open roof vent in overburn protection. Conditioned crawl space vented outside. Weatherstripping missing on ext. doors. SD's and bath fans not operating. Inspector Comments: 11/26/2012FailQuinton OwensBuilding Final Previous items completed except crawl space not insulated to R-30 per code (need REScheck) and supply vent not sealed closed. (ALL UNITS must comply) Inspector Comments: 12/10/2012PassQuinton OwensBuilding Final Bldg & Mech final ok pending RES check - OK in file 12-00149. Action required: scal supply crawl space. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00150 565 Pioneer Rd - Rockcreek Townhome #122 565 Pioneer Rd New Single Family Residence Permit Status of (Open) as of Report Date: 01/10/2020 11:08 am Permit Inspection Summary Electrical Inspection Type 06/19/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover #122 only.Inspector Comments: 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-all 6 meters.Inspector Comments: 10/30/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Upstairs master bathroom GFCI receptacle won't reset, bath fans not installed throughout, call for a re-inspect when ready. Inspector Comments: 11/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 06/14/2012PassPLL ADMINHVAC Rough-in Rough in looked good. As per Jon Berry. Inspector Comments: 10/30/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 10/19/2012PassDon AllenPlumbing Sewer 10/19/2012PassDon AllenPlumbing Water 10/19/2012PassDon AllenPlumbing Underground Inspection 10/19/2012PassDon AllenPlumbing Rough-in 10/19/2012PassDon AllenPlumbing Final Inspection Page 2 of 2