HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00150 - 565 Pioneer Rd - Rockcreek Townhome #122Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/10/2020 11:08 am
Permit Details Permit Number: 12-00150
565 Pioneer Rd - Rockcreek Townhome #122
565 Pioneer Rd
New Single Family Residence
Permit Issued Date: 06/10/2014
Permit Inspection Statistics
20Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 80.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/12/2012PassQuinton OwensFooting Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
04/12/2012PassQuinton OwensFoundation Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
06/07/2012FailQuinton OwensFraming/Structure Inspection
Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full
depth blocking required for lateral support and complete fire rating. Drywall
behind tubs on firewall. Some studs missing under girder truss bearings. Access
in wall to crawl space access is smaller than floor access opening.
Inspector Comments:
06/19/2012PassQuinton OwensFraming/Structure Inspection
overburn protection incomplete. see drywall insp. for approval.Inspector Comments:
06/26/2012PassQuinton OwensInsulation Inspection
Patch overburn protection at roof peak and any roof bent in protected area.Inspector Comments:
07/11/2012PassQuinton OwensSheetrock/Drywall Inspection
Overburn complete at peak?Inspector Comments:
10/30/2012FailQuinton OwensBuilding Final
Open roof vent in overburn protection. Conditioned crawl space vented outside.
Weatherstripping missing on ext. doors. SD's and bath fans not operating.
Inspector Comments:
11/26/2012FailQuinton OwensBuilding Final
Previous items completed except crawl space not insulated to R-30 per code
(need REScheck) and supply vent not sealed closed. (ALL UNITS must comply)
Inspector Comments:
12/10/2012PassQuinton OwensBuilding Final
Bldg & Mech final ok
pending RES check - OK in file 12-00149.
Action required: scal supply crawl space.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00150
565 Pioneer Rd - Rockcreek Townhome #122
565 Pioneer Rd
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/10/2020 11:08 am
Permit
Inspection
Summary
Electrical Inspection Type
06/19/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover #122 only.Inspector Comments:
07/23/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-all 6 meters.Inspector Comments:
10/30/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Upstairs master bathroom GFCI receptacle won't reset, bath fans not installed
throughout, call for a re-inspect when ready.
Inspector Comments:
11/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical Inspection Type
06/14/2012PassPLL ADMINHVAC Rough-in
Rough in looked good.
As per Jon Berry.
Inspector Comments:
10/30/2012PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
10/19/2012PassDon AllenPlumbing Sewer
10/19/2012PassDon AllenPlumbing Water
10/19/2012PassDon AllenPlumbing Underground Inspection
10/19/2012PassDon AllenPlumbing Rough-in
10/19/2012PassDon AllenPlumbing Final Inspection