HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00149 - 565 Pioneer Rd - Rockcreek Townhome #121Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/10/2020 11:06 am
Permit Details Permit Number: 12-00149
565 Pioneer Rd - Rockcreek Townhome #121
565 Pioneer Rd
New Single Family Residence
Permit Issued Date: 06/09/2014
Permit Inspection Statistics
19Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 84.21%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/12/2012PassQuinton OwensFooting Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
04/12/2012PassQuinton OwensFoundation Inspection
Footing & Foundation completed under permit 10 00010Inspector Comments:
06/07/2012FailQuinton OwensFraming/Structure Inspection
Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full
depth blocking required for lateral support and complete fire rating. Drywall
behind tubs on firewall. Some studs missing under girder truss bearings. Access
in wall to crawl space access is smaller than floor access opening.
Inspector Comments:
06/19/2012PassQuinton OwensFraming/Structure Inspection
06/26/2012PassQuinton OwensInsulation Inspection
07/06/2012PassQuinton OwensSheetrock/Drywall Inspection
Missing screws next to light switch in mstr closet, and in main bath on back wall,
next to sink and above light switch.
Inspector Comments:
08/03/2012FailQuinton OwensBuilding Final
CO detector required outside sleeping rooms.
Address identification.
Inspector Comments:
08/13/2012PassQuinton OwensBuilding Final
Address identification check with emer. serv.Inspector Comments:
08/14/2012PassQuinton OwensSidewalk Inspection
not a city sidewalk.Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00149
565 Pioneer Rd - Rockcreek Townhome #121
565 Pioneer Rd
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/10/2020 11:06 am
Permit
Inspection
Summary
Electrical Inspection Type
06/20/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in unit #121 only.Inspector Comments:
07/23/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-all 6 meters.Inspector Comments:
08/02/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
A/C units are not installed on roof top-30A OCPD installed, cannot final until
these are installed, call for a re-inspect when ready.
Inspector Comments:
08/13/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical Inspection Type
06/14/2012PassPLL ADMINHVAC Rough-in
As per Jon Berry.Inspector Comments:
08/13/2012PassQuinton OwensHVAC Final Inspection
Permit for AC units on roof. Guardrail/platform/access required?Inspector Comments:
Plumbing Inspection Type
08/03/2012PassDon AllenPlumbing Underground Inspection
08/03/2012PassDon AllenPlumbing Water
08/03/2012PassDon AllenPlumbing Rough-in
08/03/2012PassDon AllenPlumbing Final Inspection
All good for C/O.Inspector Comments:
Page 2 of 2