Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00149 - 565 Pioneer Rd - Rockcreek Townhome #121Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/10/2020 11:06 am Permit Details Permit Number: 12-00149 565 Pioneer Rd - Rockcreek Townhome #121 565 Pioneer Rd New Single Family Residence Permit Issued Date: 06/09/2014 Permit Inspection Statistics 19Total Inspections Completed: 16Total Inspections Passed: Inspection Pass Rate: 84.21% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/12/2012PassQuinton OwensFooting Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 04/12/2012PassQuinton OwensFoundation Inspection Footing & Foundation completed under permit 10 00010Inspector Comments: 06/07/2012FailQuinton OwensFraming/Structure Inspection Overburn protection incomplete.2hr firewall needed at floor/ No rim board - Full depth blocking required for lateral support and complete fire rating. Drywall behind tubs on firewall. Some studs missing under girder truss bearings. Access in wall to crawl space access is smaller than floor access opening. Inspector Comments: 06/19/2012PassQuinton OwensFraming/Structure Inspection 06/26/2012PassQuinton OwensInsulation Inspection 07/06/2012PassQuinton OwensSheetrock/Drywall Inspection Missing screws next to light switch in mstr closet, and in main bath on back wall, next to sink and above light switch. Inspector Comments: 08/03/2012FailQuinton OwensBuilding Final CO detector required outside sleeping rooms. Address identification. Inspector Comments: 08/13/2012PassQuinton OwensBuilding Final Address identification check with emer. serv.Inspector Comments: 08/14/2012PassQuinton OwensSidewalk Inspection not a city sidewalk.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00149 565 Pioneer Rd - Rockcreek Townhome #121 565 Pioneer Rd New Single Family Residence Permit Status of (Open) as of Report Date: 01/10/2020 11:06 am Permit Inspection Summary Electrical Inspection Type 06/20/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in unit #121 only.Inspector Comments: 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-all 6 meters.Inspector Comments: 08/02/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection A/C units are not installed on roof top-30A OCPD installed, cannot final until these are installed, call for a re-inspect when ready. Inspector Comments: 08/13/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 06/14/2012PassPLL ADMINHVAC Rough-in As per Jon Berry.Inspector Comments: 08/13/2012PassQuinton OwensHVAC Final Inspection Permit for AC units on roof. Guardrail/platform/access required?Inspector Comments: Plumbing Inspection Type 08/03/2012PassDon AllenPlumbing Underground Inspection 08/03/2012PassDon AllenPlumbing Water 08/03/2012PassDon AllenPlumbing Rough-in 08/03/2012PassDon AllenPlumbing Final Inspection All good for C/O.Inspector Comments: Page 2 of 2