HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00132 - 600 Tanglewood Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/09/2020 4:26 pm Permit Details Permit Number: 12-00132 600 Tanglewood Dr - SFR 600 Tanglewood Dr New Single Family Residence Permit Issued Date: 07/17/2014 Permit Issued Date: 10/26/2012 Permit Inspection Statistics 26Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 65.38% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/16/2012PassQuinton OwensFooting Inspection Basement ftg approved (4/16, QO)- rebar supported (must have 3" clearance underneath) Inspector Comments: 05/22/2012PassQuinton OwensFoundation Inspection 4/24/12 - Basement foundation needs 2 rebar in top 12" of wall. Rebar spacing OK. Extra full length rebar on site. (call attempted, left message 4/25, QO) 4/26 AM: foundation poured , no more rebar on site, assumed used in top of foundation. 5/22/12 - Garage: rebar verticals 48" oc horizontal 2 ft oc Inspector Comments: 07/26/2012FailPLL ADMINFraming/Structure Inspection As per Jon Berry. Attic stairs are not per code R/T add header under trusses at attic stairs Add 2 studs under girder trusses at attic stairs Maintain 6'-8" headroom for attic stairs. Add stud by light at bottom of basement stairs under header. Inspector Comments: 07/30/2012FailQuinton OwensFraming/Structure Inspection Open up roof vents in attic. Items done except stairs to attic. (no decision on fix) - no door at bottom without landing. OK to insulate. Inspector Comments: 08/07/2012PassQuinton OwensFraming/Structure Inspection Stairs to attic corrected.Inspector Comments: 08/07/2012PassQuinton OwensSheetrock/Drywall Inspection Finish garage common wall. Add screws to missed locations in house as indicated. Inspector Comments: 09/11/2012FailQuinton OwensSidewalk Inspection only 3-4" base. 6" required.Inspector Comments: 09/12/2012PassQuinton OwensSidewalk Inspection OK to pour. 6" baseInspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00132 600 Tanglewood Dr - SFR 600 Tanglewood Dr New Single Family Residence Permit Status of (Open) as of Report Date: 01/09/2020 4:26 pm Permit Inspection Summary 10/18/2012FailQuinton OwensBuilding Final House #'s needed. Handrail needed for lower section of basement stairs. Back steps not approved (key lock door from inside). CO detector outside bedrooms. 5/8" drywall separation on garage side to floor. Egress ladder or 44" max deep window well (at least 1) Bonus room: light switch at top of stairs, handrail, guardrail, window not tempered at top of stairs. Inspector Comments: 10/19/2012PassQuinton OwensBuilding Final Room above garage not to be used for any purpose until approved (see conditions) Inspector Comments: 12/04/2012PassSAUREY AMANDAInsulation Inspection Blown Cellulose in walls; ICF foundation; Attic vents maintained through bonus room ceiling. Add insulation to thin areas of floor perimeter. Floor over garage still to insulate. Seal around basement windows. Inspector Comments: Electrical Inspection Type 06/25/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 07/26/2012FailBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Outlets not installed upstairs, floor outlet required by railing, inter-system bonding termination required by main panel, tamper resistant receptacles required throughout the residence for the final, garage door opener does not have a receptacle installed, some items are notes for the final as a reminder as per the request of the owner, unfinished basement, call for a re-inspect when ready. Inspector Comments: 08/03/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-main level, unfinished basement and bonus room.Inspector Comments: 10/11/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection GFCI protection required in the laundry room by the sink and any basement receptacles, intersystem bonding termination required by the main panel, fridge has reversed polarity, spark rings required for devices in the kitchen behind cabinets (3), need to cover the NM cable in the cabinet on the peninsula and install a TR receptacle, open ground on the receptacles in the entry and front bedroom, closet light to close to the shelving in the master closet, shower trim is not rated for shower installation, cover needed for the switch in the hallway in the basement, call for a re-inspect when ready. Inspector Comments: 10/12/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished basement.Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00132 600 Tanglewood Dr - SFR 600 Tanglewood Dr New Single Family Residence Permit Status of (Open) as of Report Date: 01/09/2020 4:26 pm Permit Inspection Summary Mechanical Inspection Type 07/30/2012PassQuinton OwensHVAC Rough-in Mech rough in approved.Inspector Comments: 10/10/2012FailQuinton OwensHVAC Final Inspection Strap water heater at upper and lower thirds. High eff. furnace: cap holes on side to seal comb. chamber. Seal ends of R.A. floor plenums. Inspector Comments: 10/18/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 05/07/2012FailDon AllenPlumbing Rough-in need to put backflow device on basement toilet, bathtub, and floor drain.Inspector Comments: 05/14/2012PassDon AllenPlumbing Sewer 05/14/2012PassDon AllenPlumbing Water Check back water valves. All good to cover.Inspector Comments: 05/14/2012PassDon AllenPlumbing Underground Inspection 07/30/2012PassDon AllenPlumbing Rough-in all good to cover the rough in.Inspector Comments: 10/11/2012FailDon AllenPlumbing Final Inspection Need shut off valve on cold side of water heater.Inspector Comments: 10/19/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 3 of 3