HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00130 - 649 Centennial Loop - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/09/2020 2:19 pm Permit Details Permit Number: 12-00130 649 Centennial Loop - SFR 649 Centennial Loop New Single Family Residence Permit Issued Date: 07/17/2014 Permit Inspection Statistics 24Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 75.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/10/2012PassQuinton OwensFooting Inspection Garage ftg not ready, must have setback of 34 ft min from curb. House footings ok.(4-19, QO) Garage footing approved 5-10 (32 ft min, not 34) OK to pour footings. (5/9/12) Inspector Comments: 05/15/2012PassQuinton OwensFoundation Inspection Inspected basement Fnd. one day early, 4-25, (tall walls done- short back wall not yet done) forgot to reinspect short wall. Approved with exception. Garage fnd to be inspected.(done 5-15) Add seismic hold downs as required by engineering. Inspector Comments: 09/10/2012FailQuinton OwensSheeting Missing staples (see crayon marks). Finish nailing hold downs. R-10 continues or R-13 cavity insulation min at foundation walls. Inspector Comments: 09/13/2012PassQuinton OwensSheeting Sheathing OK to cover. Design on retaining wall over 4' ?Inspector Comments: 10/03/2012FailQuinton OwensFraming/Structure Inspection Sheathing ok to cover. Hold downs completely nailed. Design required on retaining wall over 4'. Need plate protectors for water line to patio hose bib. Headers to be doubled where required. Move lower stair light switch to bottom of stairs. Fix plumbing vent (nailed on west of house). Floor framing plan for inspection. Inspector Comments: 10/05/2012PassQuinton OwensFraming/Structure Inspection A few headers not doubled as required. (done 10-9, QO) OK to insulate.Inspector Comments: 10/09/2012FailQuinton OwensInsulation Inspection 10/11/12 - Joist cavities not insulated (east side of basement) Foundation not insulated next to furnace. Inspector Comments: 10/11/2012FailQuinton OwensInsulation Inspection 10/9/12 - Insulate exterior floor joists to R-20 min. Insulate next to furnace R-13 min. ATTIC ACCESS - 22" x 30" min. Inspector Comments: 10/16/2012PassQuinton OwensInsulation Inspection Insulation completed.Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00130 649 Centennial Loop - SFR 649 Centennial Loop New Single Family Residence Permit Status of (Open) as of Report Date: 01/09/2020 2:19 pm Permit Inspection Summary 10/25/2012PassPLL ADMINSheetrock/Drywall Inspection As per Jon Berry. 10/22/12 - Drywall on main floor and garage ok to cover. 10/25/12 - Basement drywall completed Inspector Comments: 06/12/2013PassTed DyeSidewalk Inspection 06/12/2013PassTed DyeBuilding Final Door to garage not rated. OK*** CO detectors missing outside bedrooms.OK**** No power to NE bsmt bdrm smoke detector.OK*** Window at bottom of patio stairs not tempered (called Todd on 4-3 about window shown on plans to be tempered).OK*** Inspector Comments: Electrical Inspection Type 09/19/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 09/27/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 04/01/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection GFCI protect basement kitchen receptacle by fridge, AFCI protection required for NW bedroom downstairs, protect NM cable underneath the sink in the basement kitchen, closet light to close in SW bedroom closet in basement, breaker locks needed for range-oven -microwave(240V)-master bath heater, no A/C units(2) installed(40A OCPD installed one in each panel), exterior fans not installed-blanked, main entry chandelier light blanked, upstairs south bedroom closet does not have shelving installed, call for a re-inspect when ready. Inspector Comments: 04/02/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-no A/C units installed x2 (40A OCPD).Inspector Comments: Mechanical Inspection Type 10/01/2012PassQuinton OwensHVAC Rough-in 04/02/2013FailQuinton OwensHVAC Final Inspection Door to garage not rated. Carbon Mon. Det. outside Bdrms are missing. No power to NE corner bsmt bdrm. Tempered window not at bottom of stairs. Inspector Comments: 04/03/2013PassQuinton OwensHVAC Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 12-00130 649 Centennial Loop - SFR 649 Centennial Loop New Single Family Residence Permit Status of (Open) as of Report Date: 01/09/2020 2:19 pm Permit Inspection Summary Plumbing Inspection Type 06/04/2012PassDon AllenPlumbing Underground Inspection all good to coverInspector Comments: 06/13/2012PassDon AllenPlumbing Sewer all good to coverInspector Comments: 06/13/2012PassDon AllenPlumbing Water all good to coverInspector Comments: 10/15/2012PassDon AllenPlumbing Rough-in all good to cover.Inspector Comments: 04/09/2013PassDon AllenPlumbing Final Inspection all good for the c/oInspector Comments: Page 3 of 3