HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00119 - 110 E 1st N - Allen Dental Office & Site PlanPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm Permit Details Permit Number: 12-00119 110 E 1st N - Allen Dental Office & Site Plan 110 E 1st N Commercial - Addition Permit Issued Date: 07/16/2014 Permit Inspection Statistics 20Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 90.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/16/2012PassPLL ADMINFooting Inspection As per Jon Berry. Footings and rebar look good.Inspector Comments: 05/17/2012PassPLL ADMINFoundation Inspection As per Jon Berry. Foundation and Rebar look good.Inspector Comments: 08/02/2012FailPLL ADMINFraming/Structure Inspection As per Jon Berry. 8/2 Doors locked C/N inspect. 8/2 re-insp Repair floor joist and crawlspace access. replace cut stud in hall ADA restroom not per code 60" side room Need calc's for header and girder in hall by chimney South wall plumbing and electrical needs fire rating South sheathing not nailed Anchor bolts req'd at bearing walls in basement 8/2 Hvac returns need holes sealed Exhaust fans and med gas duct needs fire dampers in south wall. Inspector Comments: 08/10/2012FailPLL ADMINSheetrock/Drywall Inspection As per Jon Berry. Interior South wall appears to be 5/8 type X (loosed) several places have type X label. OK to cover. Ext siding does not have 5/8 type X underneath per plans. Remove siding and install 5/8 type X drywall ext. grade Inspector Comments: 08/10/2012PassBret StoddardSheetrock/Drywall Inspection Approved to continue-upstairs complete, exam rooms complete except for east room, 5/8" type X sheetrock installed throughout, speaker boxes wrapped on the south wall upstairs(2), will re-inspect on Monday 8/13/12 AM ASAP. 8/13 Reinspected Exterior south wall requires 5/8Type X under siding per review notes. Inspector Comments: 09/05/2012PassPLL ADMINFraming/Structure Inspection As per Jon Berry.Inspector Comments: 09/05/2012PassPLL ADMINInsulation Inspection As per Jon Berry. Insulation looks good. OK to cover.Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00119 110 E 1st N - Allen Dental Office & Site Plan 110 E 1st N Commercial - Addition Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm Permit Inspection Summary 09/18/2012PassPLL ADMINSidewalk Inspection As per Jon Berry,Inspector Comments: 09/18/2012PassPLL ADMINBuilding Final As per Jon Berry. 8/30 Pre final Need to see fire dampers in S wall Exhaust fans CW med gas INW 4 Data boxes not rated 9/5 CW drywalled and fire caulked in. Hand rails ext and int. missing Finish ADA restroom Need engineering on beam in hall 9/5 rcvd but not on bearing in floor. Fire rings in S wall sinks required 8/31 CW Inspector Comments: Electrical Inspection Type 06/27/2012PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 08/01/2012PassBret StoddardCommercial Electrical Rough-in Approved for cover-dental office, nitrous room venting not installed-will re-inspect on the final. Inspector Comments: 09/07/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection AM Inspection-need to provide GFCI protection in the operations room and conference break room for fridge and microwave and sterile room also, lights in the conference room need to be installed, lights outside the main entry are not installed. PM Inspection-lights by the main entry (2)and upstairs in the conference room (2) are blanked off, Approved for a final and C.O. one inspection ticket was written for both inspections. Sign lights were also inspected on this final inspection-lights are mounted towards the top of the freestanding sign-see also sign permit #12-368 for more information. No separate ticket was written for the inspection of the sign. Inspector Comments: Fire Inspection Type 09/18/2012PassPLL ADMINFire Department Final Inspection As per Jon Berry. Fire ext installed at front doorInspector Comments: Mechanical Inspection Type 07/27/2012PassPLL ADMINHVAC Rough-in As per Jon Berry. HVAC looks good. Could not find gauge for gas line- could not test. Inspector Comments: 09/05/2012PassPLL ADMINHVAC Final Inspection As per Jon Berry. HVAC final completed.Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00119 110 E 1st N - Allen Dental Office & Site Plan 110 E 1st N Commercial - Addition Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm Permit Inspection Summary Plumbing Inspection Type 06/04/2012PassDon AllenPlumbing Underground Inspection All good to cover.Inspector Comments: 09/21/2012PassDon AllenPlumbing Sewer 09/21/2012PassDon AllenPlumbing Water 09/21/2012PassDon AllenPlumbing Rough-in 09/21/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 3 of 3