HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00119 - 110 E 1st N - Allen Dental Office & Site PlanPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm
Permit Details Permit Number: 12-00119
110 E 1st N - Allen Dental Office & Site Plan
110 E 1st N
Commercial - Addition
Permit Issued Date: 07/16/2014
Permit Inspection Statistics
20Total Inspections Completed:
18Total Inspections Passed:
Inspection Pass Rate: 90.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/16/2012PassPLL ADMINFooting Inspection
As per Jon Berry. Footings and rebar look good.Inspector Comments:
05/17/2012PassPLL ADMINFoundation Inspection
As per Jon Berry. Foundation and Rebar look good.Inspector Comments:
08/02/2012FailPLL ADMINFraming/Structure Inspection
As per Jon Berry.
8/2 Doors locked C/N inspect.
8/2 re-insp Repair floor joist and crawlspace access.
replace cut stud in hall
ADA restroom not per code 60" side room
Need calc's for header and girder in hall by chimney
South wall plumbing and electrical needs fire rating
South sheathing not nailed
Anchor bolts req'd at bearing walls in basement
8/2 Hvac returns need holes sealed
Exhaust fans and med gas duct needs fire dampers in south wall.
Inspector Comments:
08/10/2012FailPLL ADMINSheetrock/Drywall Inspection
As per Jon Berry. Interior South wall appears to be 5/8 type X (loosed) several
places have type X label. OK to cover. Ext siding does not have 5/8 type X
underneath per plans. Remove siding and install 5/8 type X drywall ext. grade
Inspector Comments:
08/10/2012PassBret StoddardSheetrock/Drywall Inspection
Approved to continue-upstairs complete, exam rooms complete except for east
room, 5/8" type X sheetrock installed throughout, speaker boxes wrapped on the
south wall upstairs(2), will re-inspect on Monday 8/13/12 AM ASAP.
8/13 Reinspected Exterior south wall requires 5/8Type X under siding per review
notes.
Inspector Comments:
09/05/2012PassPLL ADMINFraming/Structure Inspection
As per Jon Berry.Inspector Comments:
09/05/2012PassPLL ADMINInsulation Inspection
As per Jon Berry. Insulation looks good. OK to cover.Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00119
110 E 1st N - Allen Dental Office & Site Plan
110 E 1st N
Commercial - Addition
Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm
Permit
Inspection
Summary
09/18/2012PassPLL ADMINSidewalk Inspection
As per Jon Berry,Inspector Comments:
09/18/2012PassPLL ADMINBuilding Final
As per Jon Berry.
8/30 Pre final Need to see fire dampers in S wall Exhaust fans CW med gas INW
4 Data boxes not rated
9/5 CW drywalled and fire caulked in.
Hand rails ext and int. missing
Finish ADA restroom
Need engineering on beam in hall
9/5 rcvd but not on bearing in floor.
Fire rings in S wall sinks required
8/31 CW
Inspector Comments:
Electrical Inspection Type
06/27/2012PassBret StoddardCOM & MFR Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
08/01/2012PassBret StoddardCommercial Electrical Rough-in
Approved for cover-dental office, nitrous room venting not installed-will re-inspect
on the final.
Inspector Comments:
09/07/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
AM Inspection-need to provide GFCI protection in the operations room and
conference break room for fridge and microwave and sterile room also, lights in
the conference room need to be installed, lights outside the main entry are not
installed. PM Inspection-lights by the main entry (2)and upstairs in the
conference room (2) are blanked off, Approved for a final and C.O. one
inspection ticket was written for both inspections. Sign lights were also inspected
on this final inspection-lights are mounted towards the top of the freestanding
sign-see also sign permit #12-368 for more information. No separate ticket was
written for the inspection of the sign.
Inspector Comments:
Fire Inspection Type
09/18/2012PassPLL ADMINFire Department Final Inspection
As per Jon Berry. Fire ext installed at front doorInspector Comments:
Mechanical Inspection Type
07/27/2012PassPLL ADMINHVAC Rough-in
As per Jon Berry. HVAC looks good. Could not find gauge for gas line- could not
test.
Inspector Comments:
09/05/2012PassPLL ADMINHVAC Final Inspection
As per Jon Berry. HVAC final completed.Inspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00119
110 E 1st N - Allen Dental Office & Site Plan
110 E 1st N
Commercial - Addition
Permit Status of (Open) as of Report Date: 01/06/2020 2:04 pm
Permit
Inspection
Summary
Plumbing Inspection Type
06/04/2012PassDon AllenPlumbing Underground Inspection
All good to cover.Inspector Comments:
09/21/2012PassDon AllenPlumbing Sewer
09/21/2012PassDon AllenPlumbing Water
09/21/2012PassDon AllenPlumbing Rough-in
09/21/2012PassDon AllenPlumbing Final Inspection
All good for C/OInspector Comments: