HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00117 - 2397 W 960 S - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/06/2020 12:59 pm
Permit Details Permit Number: 12-00117
2397 W 960 S - SFR
2397 W 960 S
New Single Family Residence
Permit Issued Date: 07/16/2014
Permit Inspection Statistics
19Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 89.47%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/04/2012PassQuinton OwensFooting Inspection
Layout, rebar (clean, clearness, supported)
Ufer ground installed
Inspector Comments:
04/05/2012PassQuinton OwensFoundation Inspection
Rebar spacing & clearances ok.
Snow overnight with blizzard conditions continuing in morning. Told to "protect
concrete from freezing." Danny with Buckland concrete did not want to cover and
said it would be ok due to added hot water and calcium.
Inspector Comments:
05/02/2012PassQuinton OwensFraming/Structure Inspection
4/24/12 - Sheathing approved (4/26, QO) - Many fasteners going too deep, need
less penetration.
5/1/12 - Missing anchor bolts on interior bearing walls.(follow up on next
inspection)
Inspector Comments:
05/09/2012FailQuinton OwensInsulation Inspection
R-19 on upper floor next to garage/attic (not per IRC, REScheck, or plans)
R-11 on bsmt walls (not R-13 noted on REScheck)
Cont. in crawl space, windows .34-.35 U-factor), Blown fiberglass ext. walls. - OK
Inspector Comments:
05/09/2012PassQuinton OwensInsulation Inspection
R-19 on upper floor against garage & attic, and R-11 on bsmt walls (not per
REScheck or code or plans). Kartchner Homes warned to meet code or passing
REScheck report. Windows (.34-.35 U-factor), Blown Fiberglass in other exterior
walls.
Inspector Comments:
05/11/2012PassQuinton OwensSheetrock/Drywall Inspection
Ok to tape drywallInspector Comments:
06/19/2012PassQuinton OwensSidewalk Inspection
06/19/2012PassQuinton OwensBuilding Final
Bldg final OKInspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00117
2397 W 960 S - SFR
2397 W 960 S
New Single Family Residence
Permit Status of (Open) as of Report Date: 01/06/2020 12:59 pm
Permit
Inspection
Summary
Electrical Inspection Type
04/13/2012PassBret StoddardResidential Electrical Service Inspection
Permanent Meter Base. Approved to be energized for permanent power.Inspector Comments:
05/02/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-unfinished basement.Inspector Comments:
06/22/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
A/C unit 15A max-30A breaker installed, main panel needs a K.O. seal in the
bottom, unfinished basement, call for a re-inspect when ready.
Inspector Comments:
06/26/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement.Inspector Comments:
Mechanical Inspection Type
05/01/2012PassQuinton OwensHVAC Rough-in
Recheck return air plenums for penetrations with frame insp.Inspector Comments:
06/19/2012PassQuinton OwensHVAC Final Inspection
mech final OKInspector Comments:
Plumbing Inspection Type
04/10/2012PassDon AllenPlumbing Rough-in
05/01/2012PassDon AllenPlumbing Sewer
05/01/2012PassDon AllenPlumbing Water
05/01/2012PassDon AllenPlumbing Underground Inspection
11/09/2012PassDon AllenPlumbing Final Inspection
All good for C/OInspector Comments:
Page 2 of 2