HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00111 - 820 W 7th S - Rockwell Court Apts Bldg #9Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/06/2020 12:02 pm Permit Details Permit Number: 12-00111 820 W 7th S - Rockwell Court Apts Bldg #9 820 W 7th S New Multi-Family Residence Permit Issued Date: 04/02/2014 Permit Inspection Statistics 22Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 81.82% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/14/2013PassQuinton OwensFooting Inspection Rebar (3) #4 cont supported w. clearances ok to pour Spec. insp. on site. Inspector Comments: 02/15/2013PassQuinton OwensFoundation Inspection Ufer installed. 4 #4 horiz. bars & Vert #4 at 16" ocInspector Comments: 04/18/2013FailQuinton OwensSheeting sheer wall - exterior walls - missed locations - marked with crayon on studs. (to be reinspected with framing). Inspector Comments: 05/08/2013PassQuinton OwensSheeting 05/08/2013PassQuinton OwensFraming/Structure Inspection OK to Insulate.Inspector Comments: 05/10/2013PassQuinton OwensInsulation Inspection R-21 in walls R-11 in floors (sound) and party walls Windows V-.30 Vent Baffles in Attic Duct = R-8 Inspector Comments: 5/22,QO: 2nd floor approved. Noted to fasten drywall 24" max o.c. at each stud.Inspector Comments: 05/28/2013PassQuinton OwensSheetrock/Drywall Inspection 5/28,QO: Main level doneInspector Comments: 07/15/2013FailQuinton OwensBuilding Final Pull insulation back from crwl spc vents.Inspector Comments: 07/25/2013PassQuinton OwensBuilding Final Page 1 of 2 (Continued) Permit Details Permit Number: 12-00111 820 W 7th S - Rockwell Court Apts Bldg #9 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/06/2020 12:02 pm Permit Inspection Summary Electrical Inspection Type 05/08/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-SER cable is not installed yet-will inspect on the service inspection. Inspector Comments: 05/20/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-5 meters.Inspector Comments: 07/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-inspected this building entirely on 7/18, this is a re-inspect. Inspector Comments: Fire Inspection Type 05/02/2013PassDale PickeringFire Sprinkler Rough-in 900 - 1000 -200 psi ok to cover. Inspector Comments: 07/24/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-witnessed fire alarm test 24 hour 5 minute, flow test-35 seconds, DB witnessed at 80 DB at pillow level in bedrooms, smoke detectors tested, final report from fire alarm contractor is in permit 12-103. Inspector Comments: Mechanical Inspection Type 05/02/2013FailQuinton OwensHVAC Rough-in firecaulk around dryer vents jpenetrating floor/ceiling assemblies. finish dryer vent in lower right unit firecaulk all holes in lower level bath fans. Inspector Comments: 05/10/2013PassQuinton OwensHVAC Rough-in 07/15/2013PassQuinton OwensHVAC Final Inspection mech final OKInspector Comments: Plumbing Inspection Type 05/28/2013PassDon AllenPlumbing Rough-in 5/7/13 DA: 900 all good to cover rough in.Inspector Comments: 07/09/2013PassDon AllenPlumbing Water Good to cover water line for apt. 1,2,3,7,8,9,Inspector Comments: 07/15/2013FailDon AllenPlumbing Final Inspection 07/19/2013PassDon AllenPlumbing Sewer 07/19/2013PassDon AllenPlumbing Final Inspection Page 2 of 2