HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00110 - 820 W 7th S - Rockwell Court Apts Bldg #8Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am Permit Details Permit Number: 12-00110 820 W 7th S - Rockwell Court Apts Bldg #8 820 W 7th S New Multi-Family Residence Permit Issued Date: 04/02/2014 Permit Inspection Statistics 22Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 77.27% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 1/22/13 TD: West exterior footing and cross interior footing.Inspector Comments: 1/24/13 TD: Rebar in footing as per plans Included from center of building to east end of building with some middle cross footing. ****Mass footing on either end are not poured yet. ****** Inspector Comments: 01/28/2013PassTed DyeFooting Inspection 1/30/13 QO: vert #4 bars @ 16" o.c. -Horiz #4 bars at 8" o.c. -Int fts (3) #4's cont small spot fts (3) #4's each way large ftg. 5 #4's each way. Inspector Comments: 01/28/2013PassTed DyeFoundation Inspection 1/25/13 TD: foundation approved to pour on west half of building.Inspector Comments: 03/13/2013PassQuinton OwensSheeting Missed studs/nails marked and nailed at time of inspection.Inspector Comments: 4/15/13 QO: Make sure rough door openings in type B units are good for 2'10" doors. Firecaulk all penetrations through attic partitions. Inspector Comments: 04/15/2013PassQuinton OwensFraming/Structure Inspection 5/1/13 QO: Last of the fire partition penetrations firecaulked.Inspector Comments: 04/25/2013FailQuinton OwensInsulation Inspection 4/25, QO: Upper floor insulation. (studs not replaced in party walls) lower level not ready. Inspector Comments: 05/01/2013PassQuinton OwensInsulation Inspection 5/1, QO: walls=R21, Windows=U.30, Doors and windows sealed.Baffles installed.Inspector Comments: 5/6,QO: Upper level units ok to tape (all 5/8" type x) (glued w/ screws at 24" oc)Inspector Comments: 5/8,QO: All 5/8" type x. (glued w/ screws 24" oc.) East twnhm and one lower unit. Inspector Comments: 05/14/2013PassQuinton OwensSheetrock/Drywall Inspection 5/14: QO - West end twnhm ok; Ted - 2 last lower units okInspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00110 820 W 7th S - Rockwell Court Apts Bldg #8 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am Permit Inspection Summary 07/17/2013FailQuinton OwensBuilding Final 8101: main flr bdrm smk det. not working. CO det. needed in hall upstairs. Radon tube to be UNDER vapor barrier. 8102: Pony wall stud missing near front of crawl space. 8104: Tighten nuts on anchor bolts in crawl space. Sprinkler escutcheon not tight to ceiling. 8205: Fix sprinkler head in bathrm. Outside parking and sidewalks not done. Inspector Comments: 07/25/2013PassQuinton OwensBuilding Final Electrical Inspection Type 04/10/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover in the units throughout the entire building-10 units total.Inspector Comments: 04/24/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-ufer must remain accessible because it is not irreversible. Inspected the service and the fire alarm rough-in on the same inspection and ticket. Inspector Comments: 07/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-inspected this building entirely on 7/18, this is a re-inspect. Inspector Comments: Fire Inspection Type 04/24/2013PassBret StoddardFire Alarm Rough-in Approved for cover-fire alarm rough-in and service were inspected on the same inspection and ticket. Inspector Comments: 07/24/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O.-witnessed fire alarm test 24 hour 5 minute, flow test-35 seconds, DB witnessed at 80 DB at pillow level in bedrooms, smoke detectors tested, final report from fire alarm contractor is in permit 12-103. Inspector Comments: Mechanical Inspection Type 04/10/2013FailQuinton OwensHVAC Rough-in 4/10/13 DA: need to duck matte slm semas *disapproved.Inspector Comments: 04/12/2013PassDon AllenHVAC Rough-in mech is all good to cover in 800 building.Inspector Comments: 07/17/2013FailQuinton OwensHVAC Final Inspection Covered Bath Vent (8102 & 8105); Covered Range hood vent (8104); 3 microwaves left to connect to vent. Inspector Comments: 07/19/2013PassDon AllenHVAC Final Inspection All good for the C/OInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00110 820 W 7th S - Rockwell Court Apts Bldg #8 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am Permit Inspection Summary Plumbing Inspection Type 05/28/2013PassDon AllenPlumbing Rough-in 4/10/13 DAL all good to cover rough in.Inspector Comments: 07/09/2013PassDon AllenPlumbing Water Good to cover water line for at 1,2,3,7,8,9Inspector Comments: 07/15/2013FailDon AllenPlumbing Final Inspection Check over flow on tub Need to strap expatin tank on water heaters Ball valve on main line Dubble check tested Inspector Comments: 07/19/2013PassDon AllenPlumbing Final Inspection Page 3 of 3