HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00110 - 820 W 7th S - Rockwell Court Apts Bldg #8Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am
Permit Details Permit Number: 12-00110
820 W 7th S - Rockwell Court Apts Bldg #8
820 W 7th S
New Multi-Family Residence
Permit Issued Date: 04/02/2014
Permit Inspection Statistics
22Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 77.27%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
1/22/13 TD: West exterior footing and cross interior footing.Inspector Comments:
1/24/13 TD: Rebar in footing as per plans
Included from center of building to east end of building with some middle cross
footing.
****Mass footing on either end are not poured yet. ******
Inspector Comments:
01/28/2013PassTed DyeFooting Inspection
1/30/13 QO: vert #4 bars @ 16" o.c.
-Horiz #4 bars at 8" o.c.
-Int fts (3) #4's cont
small spot fts (3) #4's each way
large ftg. 5 #4's each way.
Inspector Comments:
01/28/2013PassTed DyeFoundation Inspection
1/25/13 TD: foundation approved to pour on west half of building.Inspector Comments:
03/13/2013PassQuinton OwensSheeting
Missed studs/nails marked and nailed at time of inspection.Inspector Comments:
4/15/13 QO: Make sure rough door openings in type B units are good for 2'10"
doors. Firecaulk all penetrations through attic partitions.
Inspector Comments:
04/15/2013PassQuinton OwensFraming/Structure Inspection
5/1/13 QO: Last of the fire partition penetrations firecaulked.Inspector Comments:
04/25/2013FailQuinton OwensInsulation Inspection
4/25, QO: Upper floor insulation. (studs not replaced in party walls)
lower level not ready.
Inspector Comments:
05/01/2013PassQuinton OwensInsulation Inspection
5/1, QO: walls=R21, Windows=U.30, Doors and windows sealed.Baffles installed.Inspector Comments:
5/6,QO: Upper level units ok to tape (all 5/8" type x) (glued w/ screws at 24" oc)Inspector Comments:
5/8,QO: All 5/8" type x. (glued w/ screws 24" oc.) East twnhm and one lower
unit.
Inspector Comments:
05/14/2013PassQuinton OwensSheetrock/Drywall Inspection
5/14: QO - West end twnhm ok; Ted - 2 last lower units okInspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00110
820 W 7th S - Rockwell Court Apts Bldg #8
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am
Permit
Inspection
Summary
07/17/2013FailQuinton OwensBuilding Final
8101: main flr bdrm smk det. not working. CO det. needed in hall upstairs. Radon
tube to be UNDER vapor barrier. 8102: Pony wall stud missing near front of crawl
space. 8104: Tighten nuts on anchor bolts in crawl space. Sprinkler escutcheon
not tight to ceiling. 8205: Fix sprinkler head in bathrm. Outside parking and
sidewalks not done.
Inspector Comments:
07/25/2013PassQuinton OwensBuilding Final
Electrical Inspection Type
04/10/2013PassBret StoddardCommercial Electrical Rough-in
Approved for cover in the units throughout the entire building-10 units total.Inspector Comments:
04/24/2013PassBret StoddardCOM & MFR Electrical Service Inspection
Approved to be energized for permanent power-ufer must remain accessible
because it is not irreversible. Inspected the service and the fire alarm rough-in on
the same inspection and ticket.
Inspector Comments:
07/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O.-inspected this building entirely on 7/18, this is a
re-inspect.
Inspector Comments:
Fire Inspection Type
04/24/2013PassBret StoddardFire Alarm Rough-in
Approved for cover-fire alarm rough-in and service were inspected on the same
inspection and ticket.
Inspector Comments:
07/24/2013PassBret StoddardFire Alarm Final Inspection
Approved for a final and C.O.-witnessed fire alarm test 24 hour 5 minute, flow
test-35 seconds, DB witnessed at 80 DB at pillow level in bedrooms, smoke
detectors tested, final report from fire alarm contractor is in permit 12-103.
Inspector Comments:
Mechanical Inspection Type
04/10/2013FailQuinton OwensHVAC Rough-in
4/10/13 DA: need to duck matte slm semas *disapproved.Inspector Comments:
04/12/2013PassDon AllenHVAC Rough-in
mech is all good to cover in 800 building.Inspector Comments:
07/17/2013FailQuinton OwensHVAC Final Inspection
Covered Bath Vent (8102 & 8105); Covered Range hood vent (8104); 3
microwaves left to connect to vent.
Inspector Comments:
07/19/2013PassDon AllenHVAC Final Inspection
All good for the C/OInspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00110
820 W 7th S - Rockwell Court Apts Bldg #8
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/06/2020 11:56 am
Permit
Inspection
Summary
Plumbing Inspection Type
05/28/2013PassDon AllenPlumbing Rough-in
4/10/13 DAL all good to cover rough in.Inspector Comments:
07/09/2013PassDon AllenPlumbing Water
Good to cover water line for at 1,2,3,7,8,9Inspector Comments:
07/15/2013FailDon AllenPlumbing Final Inspection
Check over flow on tub
Need to strap expatin tank on water heaters
Ball valve on main line
Dubble check tested
Inspector Comments:
07/19/2013PassDon AllenPlumbing Final Inspection