HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00108 - 820 W 7th S - Rockwell Court Apts Bldg #6Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm Permit Details Permit Number: 12-00108 820 W 7th S - Rockwell Court Apts Bldg #6 820 W 7th S New Multi-Family Residence Permit Issued Date: 04/02/2014 Permit Inspection Statistics 25Total Inspections Completed: 21Total Inspections Passed: Inspection Pass Rate: 84.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 3/7, QO: 3 #4 rebar cont. per plans (partial pour, all except southwest corner and interior) Inspector Comments: 3/11: remaining ext. footings approved for pour.Inspector Comments: 03/13/2013PassQuinton OwensFooting Inspection 3/13: Interior & replacement of some damaged ext footing, approved for pour.Inspector Comments: 3/7 QO: 3 #4 rebar cont (partial pour: all except southwest corner and int. ftg's) Inspector Comments: 3/11; Vert #4 at 16" oc. and 4 #4 horiz. rebar. (Partial pour - all except southwest corner). Inspector Comments: 03/14/2013PassQuinton OwensFoundation Inspection 3/14: Southwest corner approved. Ufer installed.Inspector Comments: 5/21,QO: Several locations missed. Re-inspect at framing.Inspector Comments: 08/06/2013FailQuinton OwensFraming/Structure Inspection 8/6,QO: Drywall backing needed by entry closet (7101). Fix firecaulk by range vent (7101). Turn studs or add stud at side of closet by front door (all middle apts). Holddowns missing bolts (7103). Finish firclk at tub drain (7202). Patch holes in attic separations. Finish / fix firclk (7104). Nail side of hanger by kitch (7104). No gap to slide drywall behind range vent upstairs as usually done (end units). Inspector Comments: 08/06/2013PassQuinton OwensFraming/Structure Inspection 08/08/2013FailQuinton OwensInsulation Inspection 8/8,QO: missed seal around window in back(7103). Vent baffles connecting lower attic to upper attic (end units) Inspector Comments: 08/09/2013PassQuinton OwensInsulation Inspection 8/16,QO: middle 4 units- all ok except Back left bdrm missing stud in party wall (6103 & 6202) Inspector Comments: 8/20,QO: Middle 4 units approved.Inspector Comments: 08/23/2013PassQuinton OwensSheetrock/Drywall Inspection 8/23,QO: East & West units approved (add missing screws to a few locations as marked) Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00108 820 W 7th S - Rockwell Court Apts Bldg #6 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm Permit Inspection Summary 09/23/2013FailQuinton OwensBuilding Final 6104: smk det missing outside main floor bdrm. 6101: Electrical not ready. Firecaulk at water heater vents (6102&6103). Install heater in riser room. Inspector Comments: 09/24/2013PassQuinton OwensBuilding Final Bldg & mech final completeInspector Comments: Electrical Inspection Type 08/02/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-fire alarm wiring and electrical-inspected this on the electrical rough-in inspection. Inspector Comments: 08/02/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-inspected on the rough-in inspection. Inspector Comments: 09/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O. for building #600-electrical only.Inspector Comments: Fire Inspection Type 08/02/2013PassBret StoddardFire Alarm Rough-in Approved for cover-fire alarm wiring-inspected this on the electrical rough-in inspection. Inspector Comments: 08/05/2013PassDale PickeringFire Sprinkler Hydro 07/30/13: Hydro 1500-200psi/ 1730 = 200 psi. Sprinkler rough in looks good, no issues, per Chief Child. Inspector Comments: 09/24/2013PassDale PickeringFire Department Final Inspection 09/24/2013PassDale PickeringFire Sprinkler Final Inspection 09/26/2013PassDale PickeringFire Underground Inspection Also approve fire sprinkler testing.Inspector Comments: 09/27/2013PassBret StoddardFire Alarm Final Inspection 24 hour/5minute test witnessed from 3:31PM 9/23 to 3:35PM 9/24, signalling and initiating devices witnessed operation, 31 seconds for flow switch to operate the fire alarm system, monitoring was compromised for the entire system and a fire watch was in place for 2 days-monitoring was restored and witnessed on 9/27 inspection, Approved for a final and C.O. in building #600 only, report in file from Fire Services of Idaho(Martin). Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00108 820 W 7th S - Rockwell Court Apts Bldg #6 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm Permit Inspection Summary Mechanical Inspection Type 7/9,QO: Firecaulk gas lines on East townhouse side of fire partition.Inspector Comments: 08/06/2013PassQuinton OwensHVAC Rough-in 8/6,QO: fix bth exhaust fan hanging down. (done 8-8)Inspector Comments: 09/23/2013FailQuinton OwensHVAC Final Inspection Cap concentric vents on both end units. Secure WH condensate pipe to drain (6103, 6203). Anchor gas pipe in WH closet (6102, 6101) Inspector Comments: 09/24/2013PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 07/09/2013PassDon AllenPlumbing Water Good to cover water line for at 1,2,3,7,8,9,Inspector Comments: 09/23/2013PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: 09/24/2013PassDon AllenPlumbing Sewer 09/24/2013PassDon AllenPlumbing Rough-in 6/25 DA: all good to cover rough in.Inspector Comments: Page 3 of 3