HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00108 - 820 W 7th S - Rockwell Court Apts Bldg #6Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm
Permit Details Permit Number: 12-00108
820 W 7th S - Rockwell Court Apts Bldg #6
820 W 7th S
New Multi-Family Residence
Permit Issued Date: 04/02/2014
Permit Inspection Statistics
25Total Inspections Completed:
21Total Inspections Passed:
Inspection Pass Rate: 84.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
3/7, QO: 3 #4 rebar cont. per plans (partial pour, all except southwest corner
and interior)
Inspector Comments:
3/11: remaining ext. footings approved for pour.Inspector Comments:
03/13/2013PassQuinton OwensFooting Inspection
3/13: Interior & replacement of some damaged ext footing, approved for pour.Inspector Comments:
3/7 QO: 3 #4 rebar cont
(partial pour: all except southwest corner and int. ftg's)
Inspector Comments:
3/11; Vert #4 at 16" oc. and 4 #4 horiz. rebar. (Partial pour - all except
southwest corner).
Inspector Comments:
03/14/2013PassQuinton OwensFoundation Inspection
3/14: Southwest corner approved. Ufer installed.Inspector Comments:
5/21,QO: Several locations missed. Re-inspect at framing.Inspector Comments:
08/06/2013FailQuinton OwensFraming/Structure Inspection
8/6,QO: Drywall backing needed by entry closet (7101). Fix firecaulk by range
vent (7101). Turn studs or add stud at side of closet by front door (all middle
apts). Holddowns missing bolts (7103). Finish firclk at tub drain (7202). Patch
holes in attic separations. Finish / fix firclk (7104). Nail side of hanger by kitch
(7104). No gap to slide drywall behind range vent upstairs as usually done (end
units).
Inspector Comments:
08/06/2013PassQuinton OwensFraming/Structure Inspection
08/08/2013FailQuinton OwensInsulation Inspection
8/8,QO: missed seal around window in back(7103). Vent baffles connecting lower
attic to upper attic (end units)
Inspector Comments:
08/09/2013PassQuinton OwensInsulation Inspection
8/16,QO: middle 4 units- all ok except Back left bdrm missing stud in party wall
(6103 & 6202)
Inspector Comments:
8/20,QO: Middle 4 units approved.Inspector Comments:
08/23/2013PassQuinton OwensSheetrock/Drywall Inspection
8/23,QO: East & West units approved (add missing screws to a few locations as
marked)
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00108
820 W 7th S - Rockwell Court Apts Bldg #6
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm
Permit
Inspection
Summary
09/23/2013FailQuinton OwensBuilding Final
6104: smk det missing outside main floor bdrm. 6101: Electrical not ready.
Firecaulk at water heater vents (6102&6103). Install heater in riser room.
Inspector Comments:
09/24/2013PassQuinton OwensBuilding Final
Bldg & mech final completeInspector Comments:
Electrical Inspection Type
08/02/2013PassBret StoddardCommercial Electrical Rough-in
Approved for cover-fire alarm wiring and electrical-inspected this on the electrical
rough-in inspection.
Inspector Comments:
08/02/2013PassBret StoddardCOM & MFR Electrical Service Inspection
Approved to be energized for permanent power-inspected on the rough-in
inspection.
Inspector Comments:
09/24/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final and C.O. for building #600-electrical only.Inspector Comments:
Fire Inspection Type
08/02/2013PassBret StoddardFire Alarm Rough-in
Approved for cover-fire alarm wiring-inspected this on the electrical rough-in
inspection.
Inspector Comments:
08/05/2013PassDale PickeringFire Sprinkler Hydro
07/30/13: Hydro 1500-200psi/ 1730 = 200 psi. Sprinkler rough in looks good, no
issues, per Chief Child.
Inspector Comments:
09/24/2013PassDale PickeringFire Department Final Inspection
09/24/2013PassDale PickeringFire Sprinkler Final Inspection
09/26/2013PassDale PickeringFire Underground Inspection
Also approve fire sprinkler testing.Inspector Comments:
09/27/2013PassBret StoddardFire Alarm Final Inspection
24 hour/5minute test witnessed from 3:31PM 9/23 to 3:35PM 9/24, signalling and
initiating devices witnessed operation, 31 seconds for flow switch to operate the
fire alarm system, monitoring was compromised for the entire system and a fire
watch was in place for 2 days-monitoring was restored and witnessed on 9/27
inspection, Approved for a final and C.O. in building #600 only, report in file from
Fire Services of Idaho(Martin).
Inspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00108
820 W 7th S - Rockwell Court Apts Bldg #6
820 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 01/03/2020 12:03 pm
Permit
Inspection
Summary
Mechanical Inspection Type
7/9,QO: Firecaulk gas lines on East townhouse side of fire partition.Inspector Comments:
08/06/2013PassQuinton OwensHVAC Rough-in
8/6,QO: fix bth exhaust fan hanging down. (done 8-8)Inspector Comments:
09/23/2013FailQuinton OwensHVAC Final Inspection
Cap concentric vents on both end units. Secure WH condensate pipe to drain
(6103, 6203). Anchor gas pipe in WH closet (6102, 6101)
Inspector Comments:
09/24/2013PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
07/09/2013PassDon AllenPlumbing Water
Good to cover water line for at 1,2,3,7,8,9,Inspector Comments:
09/23/2013PassDon AllenPlumbing Final Inspection
All good for C/OInspector Comments:
09/24/2013PassDon AllenPlumbing Sewer
09/24/2013PassDon AllenPlumbing Rough-in
6/25 DA: all good to cover rough in.Inspector Comments: