Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00107 - 820 W 7th S - Rockwell Court Apts Bldg #5Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/03/2020 11:36 am Permit Details Permit Number: 12-00107 820 W 7th S - Rockwell Court Apts Bldg #5 820 W 7th S New Multi-Family Residence Permit Issued Date: 04/02/2014 Permit Inspection Statistics 24Total Inspections Completed: 22Total Inspections Passed: Inspection Pass Rate: 91.67% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 3/22: Partial (North and East side) 3 #4 rebar cont.- approved, QOInspector Comments: 3/26: SW corner of Exterior footing approved for pour. - QOInspector Comments: 3/27: Interior footings (all units except north end).approved - QOInspector Comments: 03/29/2013PassQuinton OwensFooting Inspection 3/29: North end unit interior ftgs approved.Inspector Comments: 3/26: North and East all (all but SW corner) ok to pour 4#4 horx cont. and #4 vert at 16 "o.c. Inspector Comments: 03/29/2013PassQuinton OwensFoundation Inspection 3/29: Remaining fnd walls approved for pourInspector Comments: 5/24,QO: Sheathing- Fix missed locations as marked. Re-inspect w/ framing.Inspector Comments: 9/10: Tape attic party walls. Patch holes in attic (5203, 5202). Add fireclk under tub drain- 1/8" thick is insufficient (front 5202, back 5203). Inspector Comments: 09/10/2013FailQuinton OwensFraming/Structure Inspection 9/16,QO: middle units ok to drywall. Extend vent baffles to terminate above insulation (5101,5104) gap in attic drywall (5101). firecaulk sprinkler line into stairwell (5203) Inspector Comments: 09/16/2013PassQuinton OwensFraming/Structure Inspection 09/19/2013FailQuinton OwensInsulation Inspection End units- vents not extended above insulation level between lower & upper attic (will be blocked with insul) Inspector Comments: 09/23/2013PassQuinton OwensInsulation Inspection 9/23,QO: Secure sheetrock above tub in back (5202), sheet missing screws in field on ceiling in front bdrm, front bthrm by door and wall across from tub. Inspector Comments: 10/03/2013PassPLL ADMINSheetrock/Drywall Inspection 10/3,QO: DoneInspector Comments: 10/24/2013PassTed DyeBuilding Final Page 1 of 3 (Continued) Permit Details Permit Number: 12-00107 820 W 7th S - Rockwell Court Apts Bldg #5 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 11:36 am Permit Inspection Summary Electrical Inspection Type 09/09/2013PassBret StoddardCommercial Electrical Rough-in Approved for cover-inspected the electrical service and the fire alarm wiring on this inspection also-as per Jane Shaw. Inspector Comments: 09/09/2013PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-inspected the electrical service on the rough-in inspection-as per Jane Shaw. Inspector Comments: 10/22/2013PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O. #500. (Put sticker on electrical service-Jane inspected and didn't have one). Inspector Comments: Fire Inspection Type 09/09/2013PassBret StoddardFire Alarm Rough-in Approved for cover-inspected the fire alarm wiring on the electrical rough-in inspection-as per Jane Shaw. Inspector Comments: 9/6/13 DP: 10am hydro 200psi walked around aprts for rough in. 12am hydro 205psi Action required: 4 supports needed, on in each apartments utility room. Inspector Comments: 09/23/2013PassDale PickeringFire Sprinkler Hydro 9/23/13 DP: Bldg # 500: Hydro 2 hours @ #200 -Pass, sprinkler rough-in -PassInspector Comments: 10/07/2013PassDale PickeringFire Sprinkler Final Inspection Flow test - 37 secs - pass Sprinklers - pass Inspector Comments: 10/08/2013PassDale PickeringFire Underground Inspection 10/24/2013PassDale PickeringFire Department Final Inspection Storz fittings on the hydrants - Ord 1063 Please call for any questions. Inspector Comments: 10/24/2013PassBret StoddardFire Alarm Final Inspection Approved for a final and C.O. #500, 24 hour/5 minute test witnessed, flow switch operation witnessed at 38 seconds, A/C power loss at 3:00PM 10/23 and A/C restored at 3:50PM 10/24, witnessed operation of all horn strobes and smoke detectors, witnessed operation of CO detectors(2), report in file. Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00107 820 W 7th S - Rockwell Court Apts Bldg #5 820 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 01/03/2020 11:36 am Permit Inspection Summary Mechanical Inspection Type 07/30/2013PassDon AllenHVAC Rough-in All good to cover HVAC rough in.Inspector Comments: 10/24/13 DA: need to hook up microwaves need to finish up fan in bathroom need to change out T&P drops in water heaters. Inspector Comments: 10/25/2013PassDon AllenHVAC Final Inspection 10/25/13 DA: all good for the C/OInspector Comments: Planning & Zoning 10/23/2013PassVal ChristensenPlanning and Zoning Final Inspection Landscaping complete P&Z final complete. Inspector Comments: Plumbing Inspection Type 07/09/2013PassDon AllenPlumbing Water Good to cover water line for apt 1,2,3,7,8,9.Inspector Comments: 08/19/2013PassDon AllenPlumbing Rough-in 07/9/13 DA: Approved. 8/19/13 DA: all good to cover rough in. Inspector Comments: 09/03/2013PassDon AllenPlumbing Sewer 10/25/2013PassDon AllenPlumbing Final Inspection 10/23/13 DA: all good for c/o when tubs and shower are trenal out. 10/27/13 DA: all good for the C/O. Inspector Comments: Page 3 of 3